10x Chromium Single Cell 3′ v1 (GemCode) — droplet 3′ RNA-seq with the cell barcode in the i7 read

Evidence marking. 🟢 verbatim from a primary source (the paper, or the 10x v1 user guide) · 🟡 derived or inferred · 🔴 not published. Relationships marked 🟡 (computed) were worked out with lib/; the model lives in tools/chromium_v1.py and every segment whose bases are not published is built by its inferred() helper.

The scg_lib_structs drawn page is not a source here. It is inspiration only: no sequence, length or reaction in this note or in tools/chromium_v1.py is taken from it, and agreement with it is not evidence. The 10x user guide and the Cell Ranger barcode whitelist happen to be mirrored in that repository (scg_* files, identical md5 to the copies fetched by hand); those are ordinary vendor originals and are cited as such.

10x Chromium Single Cell 3′ GE, v1 chemistry (called GemCode Single-Cell 3′ in the paper) — Zheng GXY, Terry JM, Belgrader P, Ryvkin P, Bent ZW, Wilson R, Ziraldo SB, Wheeler TD, McDermott GP, Zhu J, … Hindson BJ, Bielas JH. "Massively parallel digital transcriptional profiling of single cells." Nat Commun 8:14049 (2017). doi:10.1038/ncomms14049 · PMC5241818 · PMID 28091601 (CC-BY 4.0). Data: SRA SRP073767.

Vendor protocol: 10x Genomics, Chromium Single Cell 3′ Reagent Kits User Guide, CG00026 Rev B (v1 chemistry; Library, Gel Bead & Multiplex Kit PN-120233, Chip Kit PN-120232).

Other papers / variants: the same paper is also the catalogue's defining paper for 10x Chromium Single Cell 3′ GE V2–V4 (sibling slug 10x-chromium-single-cell-3-ge-v2-v4__10.1038+ncomms14049), which moves the cell barcode into Read 1 and the sample index to i7. That is a different library layout and is not covered here.

Sources

Fetched by tools/get_sources.py into $CHEM_DATA/sources/10x-chromium-single-cell-3-ge-v1__10.1038+ncomms14049/, never committed:

FileWhatUsed for
ncomms14049_PMC5241818.xml (+ hand-made .xml.txt)full text, JATS XML from Europe PMCpaper's description of bead oligo, workflow, RT / PCR conditions, read lengths
065912_v1.full.pdfauthor bioRxiv v1 preprintindependently checks early article methods and source-linked material; complete bead oligo not printed in inspected methods
065912_065912-1.pdf and 065912_065912-2.xlsxpreprint figure/table legends and method-comparison workbookoriginal preprint supplements; no reagent oligo table in inspected material
ncomms14049_supp_ncomms14049-s1.pdf (= …MOESM828_ESM.pdf)Supplementary InformationSupp. Table 1 (UMI length, sequencer per library) — the tables are images, read from a rendering of p. 12
ncomms14049_supp_ncomms14049-s3.xlsx (= …MOESM830_ESM.xlsx)Supplementary Data 23,388 real 14-nt cell barcodes, used to check barcode orientation
…-s2/-s4/-s5.xlsxPCA, cluster genesnot chemistry
upstream_10xChromium3v1.html.txt (and its markdown twin scg_docs_ge_10xChromium3v1.md)scg_lib_structs page (Teichlab)inspiration only, not a source — nothing is cited from or verified against it
upstream_CG00026_…_RevB.pdf(.txt) = scg_CG00026_…_RevB.PDF (md5 b1b063a6…, identical)10x Genomics v1 user guide CG00026 Rev B — a vendor original, mirrored in the scg repo under data/10X-Genomics/; the copy on disk keeps a misleading upstream_ filenamebead-oligo architecture, step-by-step conditions, kit reagent names, final-library figure, sequencing parameters 🟢
upstream_737K-april-2014_rc.txt.gz = scg_737K-april-2014_rc.txt.gz (md5 a1535b7b…, identical)Cell Ranger v1 barcode whitelist — 10x vendor data mirrored in the same repobarcode count and orientation 🟢

Could not be read: ncomms14049_PMC5241818.html is a reCAPTCHA page, not the article (the XML replaced it). The paper prints the anchored (T)30VN primer notation, and the Cell Ranger whitelist supplies individual barcode sequences. Two independent readers checked the article, preprint, all listed supplements, original v1 guide and whitelist; no complete synthesized v1 bead oligo was found in that source set. 🟡 The scope and located findings are recorded in the maintainer source checklist.

Deliberately unused: scg_adapters_Chromium.fa. Despite the scg_ prefix it is not a mirrored vendor file but scg_lib_structs' own derived adapter FASTA (chemistries/adapters/Chromium.fa), and its Beads-oligo-dT entry carries 26 N (16-nt barcode + 10-nt UMI) on a Read-1 stem, i.e. the v2+ bead design, not v1. It is neither a source nor applicable here.


1. What it is

A droplet method: cells and barcoded gel beads are co-encapsulated in a "Gel bead in EMulsion" (GEM) on an 8-channel chip; the bead dissolves and releases its oligos, RT happens inside each droplet, then the emulsion is broken and everything downstream is bulk. 🟢 (paper, Results; user guide Step 2)

Each bead oligo carries 🟢 (paper; user guide): an Illumina P7 and Read 2 sequence, a 14 bp barcode drawn from ~750,000 designed sequences, a 10 bp randomer (UMI), and an anchored 30 bp oligo-dT. Some early libraries had a 5 bp UMI (14 libraries, Supp. Table 1 — including the 68k fresh PBMCs). 🟢

New thing hereWhere else it turns up
1Cell barcode read as the i7 index (14 cycles), sample index as i5 — standard Illumina primers only, no custom read primers 🟢unique to v1; v2+ put the barcode in Read 1
2Read 2 is only 10 nt: it reads the UMI and nothing else; Read 1 (98 nt) is the cDNA 🟢inverted relative to Drop-seq / v2, where Read 1 is barcode + UMI
3Bead-delivered oligo-dT + template switching for full-length cDNA, then shear + end-repair + A-tail + ligation to put the P5 side on 🟢Drop-seq uses Nextera on cDNA; v2–v4 keep the ligation front end

The RNA front end is ordinary oligo-dT reverse transcription with a template switch; what is specific to v1 is where the barcodes sit in the reads.

2. Oligos — partial source detail, complete bead oligo unresolved

The paper prints (T)30VN, and the 10x barcode whitelist contains real 14-base barcode members. The checked v1 guide CG00026 Rev B gives a bead-oligo diagram and read positions but no complete synthesized bead oligo. Two independent reviews of the article, preprint, all listed supplements, guide and whitelist confirmed that bounded absence; it does not assert anything about unlocated private manufacturing records. Earlier revisions of this note reproduced the scg_lib_structs page's reconstruction (which that page's own author describes as an educational guess); under current policy that page is inspiration, not evidence, so those sequences are gone from this note and were never in the model.

What the guide does establish — 🟢 architecture, not bases

"primers containing (i) an Illumina P7 and R2 sequence (read 2 sequencing primer), (ii) a 14 bp 10x Barcode, (iii) a 10 bp randomer and (iv) a poly-dT primer sequence are released" — CG00026 Rev B, "Step 2 – GEM Generation & Barcoding" 🟢

"P7 and R2 (read 2 primer sequence) are added to the molecules during the GEM incubation. P5, a sample index and R1 (read 1 primer sequence) are added during library construction via end repair, A-tailing, adaptor ligation and PCR." — same guide, "Step 4 – Library Construction" 🟢

The guide's final-library figure (PDF p. 12, printed p. 3) fixes the order P7 · barcode(14) · R2 · randomer(10) · poly-dT on the bead, and the end at which each flow-cell arm enters. The paper fixes the anchored poly(T) notation and the whitelist supplies barcode members; neither gives the full bead oligo.

What tools/chromium_v1.py therefore models

Every sequence-bearing segment is created by the module's inferred() helper, so it can only ever render dotted, and the page carries the three required inferred signals (preamble caveat, INFERRED — … step captions, <inf> bases):

SegmentBases drawnStatus
P7 / P7 reverse complementillumina.P7, illumina.P7_RCcanonical Illumina constant; that the guide's "Illumina P7" is this standard sequence is 🟡
TruSeq Read 2 (and its revcomp on the library)illumina.TRUSEQ_READ2as above, for the guide's "R2 (read 2 primer sequence)" 🟡
TruSeq Read 1illumina.TRUSEQ_READ1as above, for the guide's "R1 (read 1 primer sequence)" 🟡
P5illumina.P5as above 🟡
cell barcode, UMI, i5 sample index, insert, poly(A/T)B/N/I/X/A/T placeholders of the guide's declared lengthslengths 🟢, bases not applicable
template-switch end18-nt N placeholder🟡 — exact v1 TSO bases remain unresolved in the checked paper and guide; no sequence is asserted

Nothing in the module is a v1-specific base: the constants are the vendor-documented standard Illumina parts that the guide names by role, and everything v1-specific is a placeholder. rt.SMART_HANDLE, an ISPCR handle, an SI-PCR primer and a stubby TruSeq Y-adapter duplex would all be plausible, and the earlier note asserted them, but none of them is published for this kit, so the model draws none of them.

Kit reagents the guide names — 🟢 names only

Kit reagent (CG00026 Rev B kit contents)Role the guide gives itSequence
Single Cell 3′ Gel Beadscarry the barcoded oligo released in the GEM🔴
RT Primer (lyophilized, 4 µl into the GEM master mix)not stated; the oligo-dT is on the bead, so this is a separately added oligo of unstated identity🔴
cDNA Primer MixcDNA amplification; the paper calls them "primers complementary to the switch oligos and sequencing adapters" 🟢🔴
R1 Adaptor Mixthe ligated Read-1-side adaptor🔴 (not even its end geometry is given)
SI-PCR Primer (one common tube) + Single Cell 3′ Sample Index Plate (10 µl per well)sample-index PCR; the index is read as i5, and each well "combines 4 different sequences in order to balance across all 4 nucleotides" 🟢🔴 for both, including the 4 sequences per well

What can be computed from originals — 🟡 (computed with lib/)

3. Step by step

Conditions 🟢 from the paper's methods unless marked (guide) = v1 user guide CG00026 Rev B.

  1. GEM generation. Cells, master mix (RT Reagent Mix, RT Primer, RNase Inhibitor, Additive A, RT Enzyme) and gel beads are combined in oil on the chip; ~100,000 GEMs per channel per ~6-min run, at a ~80 % gel-bead fill rate (paper). The bead dissolves and releases its oligos; cells lyse.
  2. GEM-RT: 55 °C 2 h, 85 °C 5 min, 4 °C hold. The oligo-dT primes on the poly(A) tail; at the mRNA 5′ end MMLV-type RT adds untemplated C's and switches to the TSO 🟡 (mechanism: template switching; the paper only says each cDNA "ends with a template switching oligo at the 3′ end"; the enzyme is not named 🔴). First strand, 5′→3′: P7 · CB · R2 · UMI · T30VN · <cDNA, antisense> · CCC · TSO′ 🟡
  3. Break GEMs, clean up: Recovery Agent (guide), DynaBeads MyOne Silane, then 0.6× SPRIselect.
  4. cDNA PCR (cDNA Primer Mix + Amplification Master Mix + cDNA Additive (guide)): 98 °C 3 min; 14 × (98 °C 15 s, 67 °C 20 s, 72 °C 1 min); 72 °C 1 min. The guide scales cycles with targeted cell recovery: 14 (< 2,000 cells), 12 (2,000–6,000), 10 (> 6,000). 0.6× SPRIselect. Product, at role level only 🟡: template-switch handle · <cDNA> · polyA · UMI · R2′ · CB′ · P7′.
  5. Shear to ~200 bp (Covaris M220). Double-sided SPRI size selection (guide): 30 µl SPRI to 50 µl (keep supernatant), then +10 µl SPRI to 75 µl of it (keep beads).
  6. End repair and A-tailing (guide): 20 °C 30 min, 65 °C 30 min.
  7. Adapter ligation of the R1 Adaptor Mix (guide): 20 °C 15 min; two SPRI cleanups (88 µl to 110 µl, then 50 µl to 50 µl). Only 3′-end fragments (… polyA · UMI · R2′ · CB′ · P7′) carry P7; the 5′-end (template-switch) and internal fragments have no P7 site and cannot form a P5…P7 molecule 🟡. Whether the cDNA-PCR primers' 5′ ends are blocked, so that the adaptor ligates only to the sheared end, is not addressed by any source 🔴. The adaptor's end geometry (fork, overhang, polarity, bases) is likewise unpublished 🔴.
  8. Sample index PCR (guide): 60 µl mix (Amplification Master Mix + 2 µl SI-PCR Primer) + 30 µl ligated DNA + 10 µl Sample Index from the plate; 98 °C 45 s; 10 × (98 °C 20 s, 60 °C 30 s, 72 °C 20 s); 72 °C 1 min. Each sample index is a mix of 4 different sequences for base balance (guide); the 4 sequences per set are not given 🔴. Two SPRI cleanups (100 µl to 100 µl, then 50 µl to 50 µl).
  9. QC / quantify: Bioanalyzer (guide), KAPA qPCR.

4. Final library — 🟢 order from the guide's final-library figure, 🔴 bases

Top strand, 5′→3′:

5'- P5 · i5 (8, sample index) · TruSeq Read 1 (33) · <cDNA, sense, ~3' end> · B · (A)30 · UMI (10) · revcomp(TruSeq Read 2) (34) · revcomp(CB) (14) · revcomp(P7) (24) -3'

Agreements and disagreements with the primary sources:

5. Sequencing

🟢 Paper: NextSeq 500, 2 × 75 kit, loaded at 2.1 pM, 98 bp Read 1, 14 bp I7, 8 bp I5, 10 bp Read 2 (5 bp Read 2 for the 14 early libraries with 5-nt UMI). Supp. Table 1 also lists libraries run on HiSeq 2500 Rapid Run V2, which the methods text does not mention. 🟢 Guide: same read lengths ("any other length will result in a failed run" for I7, I5 and Read 2); validated on NextSeq 500 (V2, 150-cycle) and HiSeq 2500 Rapid Run (200-cycle); standard Illumina primers only, no custom primers.

ReadPrimer (standard Illumina, 🟢 by the guide's "no custom primers"; the exact constant 🟡)ReadsLength 🟢
Read 1illumina.TRUSEQ_READ1cDNA, sense strand, from the sheared end towards the poly(A)98
Index 1 (i7)illumina.INDEX1_PRIMER14-nt cell barcode (as the whitelist writes it)14
Index 2 (i5)illumina.INDEX2_PRIMER_RC8-nt sample index8
Read 2illumina.TRUSEQ_READ210-nt UMI (then poly(T), not sequenced)10

6. Open questions

7. How this note was made (tool evaluation)

tools/get_sources.py fetched the Europe PMC XML and all supplements (twice: from the EPMC zip and from Springer, identical md5), plus the scg mirror of the 10x v1 user guide and the Cell Ranger whitelist. The saved PMC HTML page is a reCAPTCHA interstitial, and tools/doctext.py made no text twin of the XML, so the full text was converted by hand to ncomms14049_PMC5241818.xml.txt. The guide and whitelist copies that carry an upstream_ filename were downloaded by hand earlier and are byte-identical to the scg_* mirror rows in MANIFEST.tsv; they are vendor originals despite the filename. The 5- and 10-base UMI variants were checked in the preprint's ST2 workbook; the published MOESM828 extracted text has the table title but not its tabular values. tools/scrape_primers.py found anchored (T)30VN, ddPCR probes and 14-nt cell barcodes in originals. Each hit was checked in its source. No complete synthesized bead oligo was located in the bounded two-reader source set. The public page displays that scope and the exact source checklist is recorded in catalogue/source_reviews/.

8. Bounded source pass 2026-10-17 (round breadth-first-06)

Read the published article (PMC5241818 JATS text lines 25–32 Results and 252 Methods "scRNA-seq library preparation") and CG00026 Rev B (upstream_-named vendor original, md5 b1b063a6…): overview lines 960–994, kit contents 399–520, GEM-RT 2196–2238, post-GEM cleanup 2343–2535, cDNA amplification 2612–2735, library construction tips 2814–2851, shearing/size selection 2933–2977, end repair 3070–3100, adaptor ligation 3117–3250, sample index PCR and cleanups 3304–3480. Scraper hits in the article are the ddPCR validation assays (line 262), not library oligos.

Model correction. The reaction graph previously came from a shared 10x RNA recipe that drew enzymatic "cDNA fragmentation" and ligation of a "3′-dT Read-2 adapter" with a cohesive dT end. Both contradict the sources: the paper (line 252) and guide (2933–2943) shear with a Covaris M220 to ~200 bp, and the guide ligates the R1 Adaptor Mix (3117–3158), with P7/Read 2 already on the bead (972–975). tools/chromium_v1.py now declares its own route: Recovery Agent break, Silane and 0.6× SPRIselect cleanups, cDNA PCR with the two unprinted cDNA Primer Mix components, Covaris shearing, the double-sided post-shearing SPRIselect, end repair/A-tailing, R1 Adaptor ligation with end geometry explicitly unavailable, two post-ligation cleanups, SI-PCR with the common SI-PCR Primer and a Sample Index Plate well, and two post-SI-PCR cleanups. The kit RT Primer is a separate GEM master-mix input of unstated identity.

Kit numbers differ between the paper ("now sold as P/N 120230, 120231, 120232") and the guide cover (PN-120233 Library, Gel Bead & Multiplex Kit; PN-120232 Chip Kit). They name kit packaging rather than chemistry, and this pass did not resolve the mapping.