Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. The scoped inferred predecessor is the most plausible earlier declared design given the inspected mechanism and chronology; no formal descent is asserted.
Candidate same-adaptor products stay in the nuclei through partitioning; CG000168 Rev A describes no step that removes them physically. Physical amplification is not assigned: an s5/s5 fragment extended by bead primers from both ends (P5 ... P5') could be primed at both ends by SI-PCR Primer B, and a gap-filled s7/s7 fragment (s7' at both 3' ends) by the i7 primer's partial Read 2N, but the guide states no yield or suppression for either. Neither would carry both P5 and P7, which the guide says the final library provides for Illumina bridge amplification (Step 4 overview), so neither is a sequencer-compatible endpoint. Recovery through the SILANE/SPRIselect cleanups is not assigned, and no computational filter is involved.
Molecular structure is not represented in this graph.
CG000168 Rev A Step 2 overview: most GEMs contain no nuclei, and after incubation the GEMs are broken and pooled; no physical removal of empty or multiplet GEM products is described. Cell Ranger ATAC assigns barcodes computationally (Sequencing section); the products' fate is not modelled further.
Molecular structure is not represented in this graph.
Read 1N transposon top: 5'-
Read 2N transposon top: 5'-
Gel-bead oligo PN-2000132: bead-|-5'-
SI-PCR Primer B PN-2000128: 5'-
i7 Sample Index Plate N, Set A primer PN-3000262: 5'-
lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
| Read | Primer | Sequence | Lands on | First bases read |
|---|---|---|---|---|
| Read 1 | Nextera Read 1 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-3' | anneals to the bottom strand over s5, mosaic end | XXXXXXXXXXXX… (from accessible genomic DNA) |
| Index 1 (i7) | Nextera Index 1 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-CTGTCTCTTATACACATCTCCGAGCCCACGAGAC-3' | anneals to the bottom strand over opposite ME reverse complement, s7 reverse complement | NNNNNNNNATCT… (from i7 sample index read) |
| Index 2 (i5) | Nextera Index 2, reverse-complement workflow Illumina "Indexed Sequencing Overview Guide" #15057455 | 5'-CTGTCTCTTATACACATCTGACGCTGCCGACGA-3'Forward-strand instruments prime i5 off the flow-cell P5 oligo instead. | anneals to the top strand over s5, mosaic end | bbbbbbbbbbbb… (from 10x cell barcode) |
| Read 2 | Nextera Read 2 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAG-3' | anneals to the top strand over opposite ME reverse complement, s7 reverse complement | xxxxxxxxxxxx… (from accessible genomic DNA) |
| Read | Cycles | Content | Include in sequence analysis? |
|---|---|---|---|
| Read 1 | 50 | accessible genomic DNA (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end | Yes — include in sequence analysis |
| Index 1 (i7) | 8 | sample index (cycles 1–8) | No — use for sample demultiplexing |
| Index 2 (i5) | 16 | cell barcode (cycles 1–16) | No — extract identifiers only |
| Read 2 | 50 | accessible genomic DNA (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end | Yes — include in sequence analysis |