4C-seq — research notes

Citation

Krijger PHL, Geeven G, Bianchi V, Hilvering CRE, de Laat W. 4C-seq from beginning to end: A detailed protocol for sample preparation and data analysis. Methods 170, 17–32 (2020). doi:10.1016/j.ymeth.2019.07.014

Sources read

1. What it is

🟢 4C-seq asks which genomic fragments contact one chosen restriction fragment (the viewpoint). Formaldehyde fixation, primary restriction digestion and proximity ligation first make a conventional 3C library.

🟢 The purified 3C DNA is cut with a different, secondary restriction enzyme. A second dilute ligation circularizes these shorter products. Outward-facing primers in the known viewpoint then inverse-PCR the unknown ligated reporter.

2. Construct-changing steps

  1. 🟢 Crosslink cells, digest chromatin with a primary cutter and proximity-ligate spatially adjacent restriction fragments.
  2. 🟢 Reverse crosslinks and purify the 3C library.
  3. 🟢 Digest again with a secondary cutter; this reduces fragment size and defines the second boundary read from each reporter.
  4. 🟢 Ligate under dilute conditions to make circular 4C templates.
  5. 🟢 Perform viewpoint-specific inverse PCR. The protocol uses two PCR stages; the second completes Illumina-compatible adapters and sample multiplexing.

3. Final library and reads

🟢 The genomic read begins from a viewpoint-specific reading primer and proceeds across the primary restriction-ligation junction into the captured reporter. The opposite end is constrained by the secondary cutter.

🟢 The reading inverse-PCR primer has the published 5′ tail TACACGACGCTCTTCCGATCT, then a 0–5-nt optional spacer and the viewpoint-specific sequence. The non-reading primer has the published 5′ tail ACTGGAGTTCAGACGTGTGCTCTTCCGATCT, then its viewpoint-specific sequence. Table 1 gives the second-round universal forward primer, 5′-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATCT-3′, and an indexed reverse-primer panel.

🟢 Table 1 contains 24 named reverse-primer rows. The later rows, numbered 13–27, include two additional bases before the six indexing bases; the caption explicitly says these two bases are not used for indexing. The diagram represents the simpler rows 1–12 family without selecting an actual sample index.

🟡 The diagram uses the published DpnII/Csp6I combination as an illustrative branch: Table 3 uses it for the Sox2 and Mccc1 examples. Enzyme choice and genomic primer arms are experiment-specific. The optional spacer, locus sequence and sample index remain symbolic; their unknown lengths are not replaced by arbitrary biological sequence lengths.

🟢 Section 5.2 uses two PCR stages: 16 cycles, 0.8× AMPure cleanup, then 20 cycles and QIAquick purification. Section 6 describes single-end 50-base HiSeq or 75-base MiniSeq/NextSeq reads with a six-base index. The model does not assign physically loaded sequencing primers from PCR-arm identity alone.

🟢 The paper describes amplified self-ligation and undigested-fragment products (note 12, extracted lines 1226–1234). These are drawn as separate possible amplicon classes. Their exclusion from analytical metrics does not demonstrate physical removal from the library.

4. Open questions

🟡 A concrete experiment must supply its enzyme pair, viewpoint-specific primer portions, optional spacer and selected index. These are unassigned model choices, not confirmed omissions from the publication.

The source audit remains in progress. 🟢 Appendix A's publisher-hosted supplementary data (PII S1046202318304742, Elsevier mmc2.pdf and mmc3.pdf) were inspected in the 2026-10-17 capped pass: Supplemental figure 1 compares the pipe4C and 4Cseqpipe analysis modules, and Supplemental figure 2 shows read-depth coverage and between-sample correlations. Neither prints oligos, reaction conditions or library structure, so the library model is unchanged. The linked pipe4C and peakC repositories remain pending original-source scope checks. The retrieved Illumina pooling chapter is the current v17 document, a later comparator; the paper does not identify a historical revision to assign. No missing-information claim is accepted from this incomplete linked-source inventory.