Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. Plausible earlier chemistry analogue; descent or inspiration cannot be substantiated. Duplex-related molecule families and consensus error suppression on genomic DNA; BotSeqS uses endogenous coordinates and a dilution bottleneck instead of random duplex adapter tags.
A TruSeq PCR-free library is diluted after adapter ligation and before PCR; native fragment endpoints group redundant Watson and Crick read families without a synthetic UMI.
INFERRED — the canonical single-index adapter arrangement is a compatibility model; the source-named2016 kit/index-set revision and physical ends remain unassigned. The post-dilution PCR primers (TS-PCR Oligo1/Oligo2, one 3-prime phosphorothioate), Q5 Hot Start polymerase, cycling, 1.0x AMPure cleanup and the pBlueScript-carrier serial dilution are from the PNAS SI Appendix; per-library dilution (10-, 10^5- or 10^7-fold) and cycle number (18 or 20) are from Dataset S1 Table S1. The TruSeq PCR-Free adapter index set and whether an index read was acquired are not stated. INFERRED: the 350-bp size selection is placed after end repair following the 2017 TruSeq DNA PCR-Free guide; the 2016 kit revision used was not inspected.
Shear genomic DNA. Inputs: BioRuptor, high intensity, 15 s on / 90 s off, seven cycles at 3 °C
End-repair the sheared fragments. Inputs: TruSeq DNA PCR-Free end-repair reagents (standard low-input protocol)
Select the 350-bp insert size. Inputs: TruSeq DNA PCR-Free bead selection for 350-bp inserts. Other outputs: fragments outside the selected size window → discard
Add one 3-prime dA to each end. Inputs: TruSeq DNA PCR-Free A-tailing mix
Present adapter and substrate ends. The original specifies TruSeq DNA PCR-Free Y adapters, but the study-specific2016 kit/index-set revision and physical adapter ends remain unassigned. Canonical A/T compatibility diagrams are inferred hypotheses, not a source-exact reagent reconstruction.
INFERRED architecture — ligate source-named kit Y adapters. Inputs: TruSeq DNA PCR-Free Y adapters (kit/index revision unassigned); TruSeq DNA PCR-Free ligation reagents
Retain an optional matched-WGS aliquot before bottleneck dilution. Inputs: SI WGS route:10 µL of the20 µL adapter pool for matched WGS when prepared from this pool; the remaining source material supplies the bottleneck. Other outputs: adapter-ligated material assigned to BotSeqS
Amplify the retained matched-WGS aliquot. Inputs: forward component of TruSeq PCR Primer Cocktail (member unassigned); reverse component of TruSeq PCR Primer Cocktail (member unassigned); TruSeq PCR Master Mix per manufacturer instructions
Purify the matched-WGS PCR with1.0× AMPure. Inputs: 1.0× AMPure XP for WGS PCR cleanup. Other outputs: WGS cleanup supernatant → discard
purified BotSeqS library
Shear genomic DNA. Inputs: BioRuptor, high intensity, 15 s on / 90 s off, seven cycles at 3 °C
End-repair the sheared fragments. Inputs: TruSeq DNA PCR-Free end-repair reagents (standard low-input protocol)
Select the 350-bp insert size. Inputs: TruSeq DNA PCR-Free bead selection for 350-bp inserts. Other outputs: fragments outside the selected size window → discard
Add one 3-prime dA to each end. Inputs: TruSeq DNA PCR-Free A-tailing mix
Present adapter and substrate ends. The original specifies TruSeq DNA PCR-Free Y adapters, but the study-specific2016 kit/index-set revision and physical adapter ends remain unassigned. Canonical A/T compatibility diagrams are inferred hypotheses, not a source-exact reagent reconstruction.
INFERRED architecture — ligate source-named kit Y adapters. Inputs: TruSeq DNA PCR-Free Y adapters (kit/index revision unassigned); TruSeq DNA PCR-Free ligation reagents
Retain an optional matched-WGS aliquot before bottleneck dilution. Inputs: SI WGS route:10 µL of the20 µL adapter pool for matched WGS when prepared from this pool; the remaining source material supplies the bottleneck. Other outputs: optional matched-WGS aliquot (source subset)
Dilute to about one haploid-genome equivalent. Inputs: dilution of Y-adapter-ligated DNA (20 µL): serial 2 µL into 18 µL transfers in TE with 1 ng/µL pBlueScript carrier, 2 µL used as PCR template; typically 10^5-fold for 500 ng input, chosen from 10^3–10^7 dilutions test-sequenced 2x50 on MiSeq (SI Fig. S1); Dataset S1 lists 10-, 10^5- and 10^7-fold final dilutions. Other outputs: unsampled adapter stock and serial-dilution material → unresolved
PCR-amplify the bottlenecked library. Inputs: TS-PCR Oligo1 5′-AATGATACGGCGACCACCGAG*A-3′, HPLC-purified, 0.5 µM; TS-PCR Oligo2 5′-CAAGCAGAAGACGGCATACGA*G-3′, HPLC-purified, 0.5 µM; Q5 Hot Start High-Fidelity 2x Master Mix (NEB), 50 µL; 98 °C 30 s, 18 or 20 x (98 °C 10 s, 69 °C 30 s, 72 °C 30 s), 72 °C 2 min
Purify the PCR product with 1.0x AMPure XP. Inputs: AMPure XP beads, 1.0x bead-to-sample ratio. Other outputs: 1.0x AMPure supernatant (primers, short products) → discard
Other material outcomes
fragments outside the selected size window — discard
bead supernatants discarded during size selection
Molecular structure is not represented in this graph.
WGS cleanup supernatant — discard
physically removed AMPure supernatant
Molecular structure is not represented in this graph.
unsampled adapter stock and serial-dilution material — unresolved
These molecules do not enter the sampled PCR aliquot. Remaining source/serial stock is not thereby a physical discard; matched WGS retention is a separate source branch.
Molecular structure is not represented in this graph.
1.0x AMPure supernatant (primers, short products) — discard
AMPure supernatant removed
Molecular structure is not represented in this graph.
Paired reads establish both endpoints and P5/P7 orientation for Watson- and Crick-family consensus.
Final sequencing library: matched-WGS reference library (where prepared)
Sequencing limitation. SI WGS route: HiSeq2500 PE2×100,>30×. The matched reference was available for32/34 individuals; two used Sanger. Exact primer/index geometry is unassigned; no index read is guessed.
Read content and handling
Exact read placement is unresolved: SI WGS route: HiSeq2500 PE2×100,>30×. The matched reference was available for32/34 individuals; two used Sanger. Exact primer/index geometry is unassigned; no index read is guessed.
Read
Cycles
Content
Include in sequence analysis?
Read 1
100
sample index, genomic insert, dA junction (read orientation and cycle boundaries unresolved)
Yes — after extracting identifiers
Index 1 (i7)
—
not acquired
No — not sequenced
Index 2 (i5)
—
not acquired
No — not sequenced
Read 2
100
sample index, genomic insert, dA junction (read orientation and cycle boundaries unresolved)
Yes — after extracting identifiers
Final sequencing library: purified BotSeqS library
INFERRED — canonical TruSeq single-index compatibility model; error correction comes from the post-ligation bottleneck and shared genomic endpoints, not an added barcode.
Sequencing primers: purified BotSeqS library
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
anneals to the top strand over dA junction, Read2 adapter arm
… (from genomic insert)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
100
genomic insert (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Index 1 (i7)
—
not acquired
No — not sequenced
Index 2 (i5)
—
not acquired
No — not sequenced
Read 2
100
genomic insert (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end