CAGEscan — research notes

Plessy et al., Nature Methods (2010), 10.1038/nmeth.1470, original author manuscript PMC2906222. The earlier note's PMC2900199 citation was a repository error.

Originals inspected

The oligo scraper was run before reading the full source bundle. Remaining supplements, linked references and vendor instructions are not all dispositioned; this is a bounded audit.

Source-owned route

Random N6 priming and preferential template switching at capped RNA use the published TSO, with an inline three- or six-base DNA sample barcode and terminal RNA rGrGrG. CAGEscan substitutes SuperScript III or PrimeScript for the nanoCAGE SSII enzyme and cleans first-strand material using RNAClean XP.

The source then specifies two PCR stages, each with a pilot quantitative PCR:

  1. A 1.2-µL pilot aliquot of the named 30-µL first-strand pool informs cycle selection; a 3-µL aliquot goes to Ex Taq HS semi-suppressive amplification. The model computes the residual pool and leaves its later handling unresolved.
  2. AMPure XP cleanup and a 1% agarose purity check of the recovered DNA (Methods text 92–94; aliquot volume not stated, modelled as a QC aliquot since round 07) are followed by an 8-ng adapter-PCR pilot and the remaining 20-ng production reaction. This PCR introduces the paired-end sequencing ends and replaces the interfering semi-suppressive reverse end.
  3. A second AMPure XP cleanup precedes the source 5-of-30-µL agarose-gel check and concentration adjustment for Genome Analyzer II sequencing. The gel check is QC, not preparative gel selection.

The graph keeps cap-linked cDNA, other first-strand templates and primer artifacts as separate molecular classes. Semi-suppressive PCR disfavors short/homoadapter templates; it does not physically discard every artifact. Removed bead-cleanup fractions and QC aliquots have separate fates. CAGEscan does not inherit nanoCAGE's EcoP15I cleavage/ligation.

Eight published oligos and unfinished assembly

All eight source oligos remain displayed on the schematic. Six structural inputs have local molecular states: RT handle plus N6, TSO handle plus variable inline barcode and RNA tail, both semi-suppressive primers and both final PCR primers. The barcode has structured sample-identifier meaning; there is no invented eight-base instrument index.

Table 8 prints TAGTCGAACGAAG... in the RT primer and TAGTCGAACTGAAG... in the semi-suppressive reverse primer. The difference is preserved. A shorter exact 3′ match exists, so this is not classified as a proven ordered-oligo error.

Both custom sequencing primers are source-positive. Their complete assembled landing geometry, exact study barcode members and instrument cycle counts remain model questions. The unassembled initial PCR-template geometry is explicitly separate from the amplified library endpoint. This limitation is not evidence that primer sequences were unpublished.

Derived primer landings (🟡, round 07)

Computed with lib/ from the Table 8 strings (not yet assembled as model states): the forward sequencing primer equals the full 24-nt TSO handle, so Read 1 would start at the inline Xn barcode followed by the rGrGrG-derived G run and the cap-proximal cDNA. The reverse PCR and reverse sequencing primers share only their 3′-terminal 18 nt (GAACCGCTCTTCCGATCT) with the RT-primer handle (its positions 20–37), so Read 2 would start at the N6-primed downstream end, and the RT/semi-reverse 5′ segment upstream of that match is dropped, consistent with the source's statement that this PCR removes the reverse semi-suppressive adapter. The final forward primer's 3′-terminal 16 nt also occur inside the semi-suppressive reverse primer; any P5-ended product from that end is only a sequence-computed candidate, not a source observation, and is not drawn.

Apparent source concentration-unit issue

The original Online Methods printed p.17 visibly gives 100 mM semi-suppressive primers and 200 mM final-PCR primers, while nearby dNTPs are printed as 200 µM. Both readers checked the original PDF, so the primer units are not merely an extraction artifact.

The public page displays these source locations and values as an apparent unit issue. The model retains the published oligos and operation order without assigning a corrected primer concentration. The intended concentration remains unresolved.

Readout and remaining sources

One custom paired-end read enters at the cap/TSO-derived end, including the inline barcode; the other enters from the random-primer-defined downstream end. Genome Analyzer II is explicitly named. Paired-end alignment, rDNA alignment exclusion and collapsing identical mapping pairs are computational operations, not physical library purification.

The review remains in progress for actual linked materials, including reference 16 (Bentley et al. 2008, DOI 10.1038/nature07517), cited nanoCAGE/RT methodological provenance, manufacturer instructions for RNAClean XP/AMPure XP, and remaining supplement scope. No unavailable “instrument-context document” is invented from the unfinished model. No missing-information claim is accepted at this checkpoint.