CATCH-Seq: BAC-derived RNA probes and genomic-library capture

Published defining original: Day et al., PLOS ONE2014, DOI10.1371/journal.pone.0111756. This is clone-adapted template capture hybridization, distinct from Cas9-assisted CATCH and CATCH-IT.

Closed source scope

🟢 Published main PMC4214737 Methods47–66, Results76–85/Fig1caption83, original PDFp2–4, and actual TableS1(s005) DOCX table cells. TableS1 contains acquisition/target summaries; region6 has24plex capture and sequencing with HiSeqPE100. These two originals support the selected standard24plex preparation and a source-declared acquisition example, without assigning every generic reference-recipe quantity to one historical cohort. No preprint/version merge, full source audit or accepted absence. Source investigation closed before implementation; third slot unused/reserved for the same-source peer.

Mandatory available-bundle scraper returned4hits/2representations of the main, with false line-wrap truncations. Whole adapter orders were verified in the actual printed PDFp2. TableS1 original ZIP/XML has no embedded images; header and region6 row cells were inspected directly. Other supplemental images and S2 cost comparison were not read/adopted.

Known molecular component

🟢 Whole T7-adapter orders are TACTACTAATACGACTCACTATAGGGT and CCCTATAGTGAGTCGTATTAGTAGTA. Computation gives27/26nt,26bp pairing and a protruding3′T. Ordered5′phosphate/end chemistry is unassigned, not inferred from ligation intent. A later source-named T7F oligo is separately added after ligation; its whole-order assignment is not explicitly mapped in the inspected text and remains unassembled. The source states that this annealing generates duplex promoter regions on single-stranded antisense templates; whole occupied BAC junctions and transcript boundaries remain unassembled.

Physical preparation and readout

🟢 Each sample genomic DNA input is quantified and gel-QCed, then700ng–2.5µg is adjusted to80µl for Covaris shearing. End repair, dA-tail and QuickLigation modules are separated by1.8×SPRI cleanups using source Sera-Mag/NaCl/PEG buffer. One nonmethylated inline-barcode adapter set is used per sample; selected contributions of independently prepared sample libraries form an equal24plex2µg capture pool. Adapter bodies, selected barcode values and exact ligation-end geometry remain unassembled rather than borrowed from a canonical Illumina kit.

🟢 BAC stocks are identity-QCed and physically pooled by contribution to composite target size, typically4µg total, before shearing and the same local repair/A-tail operations. T7 adapters replace the sample barcode adapters. After cleanup,100–200pmolT7F is annealed in35µl with PCR buffer/MgCl2. Cleaned template is eluted36µl and allocated into three actual12µl IVTs. Each MegascriptT7 reaction includes biotin-11-UTP, runs1.5h, receives DNase, then1µl0.5MEDTA and75°C10min. Only after these reactions are their products physically pooled;2µl is removed for gel QC. NucAway cleanup removes free nucleotides, followed by QubitRNA/Bioanalyzer QC and selected probe allocation. Biotin labels RNA nucleotides; it is not a sample barcode/UMI and does not imply every U is modified.

🟢 The selected standard24plex pool2µg receives40-foldCot-1 and is concentrated30µl. Probe amount follows2500×theoreticaltarget-mass guidance with exact amount unassigned, made20µl with1–2µlSUPERase-In. Preheated52µl2×hybridization buffer, heat-treated library/Cot-1 and probe form the source104µl reference reaction; volume-addition convention remains explicit because probe/inhibitor wording is not silently normalized. Hybridize65°C24–60h. C1 capture uses the stated35µl beads per52µl reference, followed by two room-temperature and four65°C washes. The exact104µl bead scaling/execution is unassigned in the partial model.

🟢 Standard libraries are eluted with0.1MNaOH10min; transfer eluate to70µl1MTris7.5, SPRI-clean and elute35µlwater. The bisulfite branch is separate and not mixed into this standard route. Selected template is amplified with source PlatinumTaq, standard functional Illumina primer pair, betaine/dNTP/MgCl2/buffer;18–22cycles. Source whole primers remain unassembled. SPRI cleanup, Bioanalyzer and KAPAqPCR QC precede selected final loading, preserving unused stocks. Source TableS1 region6 supports PE100; no complete primer-landing/index-cycle geometry is invented.

Source wording and remaining limits

Methods prescribes40-foldCot-1, while the repeat-blocking Results describes a typically20:1 ratio and a2.5–20fold series. The model selects the Methods reference recipe and preserves both scopes without declaring an error or silently replacing40with20. PCRcycle range, sample DNA mass and historical stock doses remain ranges/unassigned study values. Targeted capture is not perfect purity; DNA/RNA/off-target and workup fractions stay explicit.

Canonical sample adapters, exact T7F identity, full allele/BAC/transcript sequences, reagent kit historical formulations, unassigned barcode/index acquisition and complete occupied products need further source work. The source explicitly credits Dexheimer's inline adapter design/software but does not identify an inspected standalone oligo document in this pass. Desired component specifications are open questions, not fabricated unavailable documents. Ordinary linked predecessors/vendor originals remain unread; no recipe is inherited from similarity.

Public preparation page

The public page displays the source-defined preparation, known local oligos/duplexes, read setup, unresolved molecular boundaries and all material fates. Analytical fractions have the QC material type. A curator-written inventory covers external inputs and operations; repetition is parameterized only by the source-defined sample/IVT counts, without scanning the graph to manufacture coverage. Passing this workflow gate does not establish the unassembled molecular transitions or complete source review.