CEL-Seq2 — source note
The detailed source audit, oligo transcriptions, protocol steps, and comparison with the original CEL-Seq method are retained in the companion CEL-Seq / CEL-Seq2 research note.
Defining source: Hashimshony T et al. “CEL-Seq2: sensitive highly-multiplexed single-cell RNA-Seq.” Genome Biology 17, 77 (2016). doi:10.1186/s13059-016-0938-8.
The schematic uses the CEL-Seq2 RT-primer and randomhexRT sequences printed in Supplementary Table S2 (Additional file 5, MOESM5) and the 96-member primer list in the detailed protocol (Additional file 4, MOESM4). Additional file 6 (MOESM6) is the separate Fluidigm C1 workflow, not an oligo table; this schematic follows the manual well workflow. The detailed protocol calls for Illumina RP1 and indexed RPIX, directing readers to Illumina for their sequences. The official Illumina TruSeq Small RNA adapter table (document 1000000002694 v22) prints both oligos and the RPI index table. The model uses RP1 and representative RPI1; the actual indexed RPIX member used in each experiment is not specified. Their 3′ ends land on 16 and 21 known bases, respectively, of the selected CEL-Seq2 cDNA template. The transcript insert and cell UMI/barcode are variable; sequencing-primer placement remains unverified.
Bounded source pass, 2026-10-17 (round breadth-first-07)
Read in the published PMC4848782 package ($CHEM_DATA/sources/cel-seq2__10.1186+s13059-016-0938-8/): JATS Results (primer shortening, reagent changes, ligation-free library, C1) and Methods (CEL-Seq2 modifications 1–4, Barcode design, Sequencing); Additional file 4 detailed protocol, docx text lines 1–49 (reagents, primer design) and 166–339 (cell isolation through library QC and sequencing); Additional file 5 Table S2 (lines 1–21). The oligo scraper was run on the bundle; the RT-primer family (lines 51–146 of Additional file 4), Table S2 designs and randomhexRT were checked against those lines.
Changes to the schematic, all 🟢 from Additional file 4:
- The tube/plate workflow is now declared step by step in
tools/chem.pyinstead of through the shared barcoded-IVT helper: SuperScript II RT (42 °C 1 h) with ERCC spike-in, 70 °C 10 min heat inactivation, second strand with E. coli DNA polymerase I, E. coli DNA ligase and RNase H (16 °C 2 h), pooling of the cells for one IVT, AMPure XP with PEG/NaCl bead buffer, MEGAscript T7 IVT (37 °C 13 h), ExoSAP-IT "to remove primers" (37 °C 15 min), Mg²⁺ fragmentation (94 °C 3 min) with EDTA stop, 1.8× RNAClean XP, randomhexRT library RT (25 °C 10 min, 42 °C 1 h), Phusion HF PCR with RP1/RPIX (11 cycles, up to 15) and two 1× AMPure XP cleanups. - Unincorporated RT primers are carried as a separate material from the first RT to the ExoSAP-IT step; their digestion products are only removed physically by the RNAClean XP cleanup. Whether the earlier cDNA bead cleanup already removes some of them is not stated. 🟡
- Apparent source inconsistency on the barcode set, shown on the page: the protocol says "If not using all 48 primers" (line 48) but lists 96 primers (lines 51–146), and the Methods say 168 barcodes were selected. The schematic draws one variable 6-nt barcode and does not choose a set size.
Still open: the protocol allows replacing the cDNA bead cleanup by 65 °C for 20 min (not drawn as a branch); internal aRNA fragments without the RA5/UMI/barcode end are not drawn as an off-product; the actual RPIX indices; the Fluidigm C1 branch (Additional file 6); and the CEL-Seq 2012 predecessor paper, which remains inaccessible.