ChRO-seq β research notes
Chu et al., Nature Genetics (2018), 10.1038/s41588-018-0244-3, original author manuscript.
Sources and scope
- π’ Original article Methods: chromatin isolation, ChRO library preparation and mapping (
s41588-018-0244-3_PMC6204104.xml.txt, lines 150β158), plus the actual external-link inventory and references 27β28. - π’ Original Supplementary Table 1, first sheet of the MOESM3 workbook (text lines 1β40): sample/replicate-specific run-on method and βUnique molecular index barcodeβ column.
- π’ Mahat et al., Nature Protocols (2016), 10.1038/nprot.2016.086: original PRO-seq overview, Table 1 and the adapter/end-repair steps. This is the explicitly cited predecessor, not proof that every ChRO library used unchanged oligos.
- π’ Supplementary Notes 1β7 and the table legends were read for referring scope: assay comparisons, biological analysis and the dREG-HD computational method. This does not constitute a complete visual audit of the 30 supplementary figures or all result tables.
The oligo scraper was run on the complete bundles before source reading. Its output is a reading aid, not proof that source information is absent.
Source-owned ChRO route
- π’ NUN isolation retains a chromatin pellet, followed by washes and sonication in chromatin storage buffer to suspend the pellet. The source retains engaged polymerases.
- π’ Run-on supplies ATP and GTP with biotin-11-CTP and biotin-11-UTP in Sarkosyl-containing buffer (2Γ buffer with 300 mM KCl and 1% Sarkosyl, mixed 1:1 with chromatin; 37 Β°C, 5 min). The nascent RNA acquires affinity labels during extension; those labels are not UMIs and have no assigned eight-base length.
- π’ Trizol LS stops the reaction; GlycoBlue-assisted recovery yields RNA, heat-denatured at 65 Β°C for 40 s. ChRO then uses base hydrolysis (0.2 N NaOH, on ice, 8 min), intended to yield 40β100-base RNA fragments.
- π’ First streptavidin capture and Trizol release recover biotin-containing RNA.
- π’ The 3β² RNA adapter is ligated using the source M0204L reagent.
- π’ Second streptavidin capture is followed by RppH decapping, PNK 5β² phosphorylation and Trizol purification. The cited predecessor makes the intervening bead release explicit; these steps prepare RNA for 5β²-adapter ligation.
- π’ Ligate the 5β² RNA adapter, then perform the third streptavidin capture/recovery.
- π’ Reverse transcription (source 18080-044) and PCR (M0491L) generate an Illumina-compatible library. The defining article names NextSeq 500, but no universal cycle mask is selected by this model.
The local graph declares all three captures, both adapter ligations and their source order. Extraction and binding/wash removed fractions have physical discard fates; these are not computational deduplication or a guarantee that every unbound molecule lacks label. The graph does not infer an exact adapter-ligation or PCR geometry from a finished endpoint.
ChRO and leChRO differ
π’ leChRO is length-extension ChRO. RNase cocktail replaces the RNase inhibitor during initial isolation; post-run-on hydrolysis is omitted. It is not an extra linear-amplification branch. The previous note's description was a repository error and has been corrected. This page's reaction graph shows the ChRO branch and annotates the leChRO differences.
π’ Source mapping interprets the nascent RNA 3β² end from the read 5β² end in ChRO, and RNA 5β² end from the read 3β² end in leChRO. These are read-orientation statements, not an assignment of an arbitrary modern sequencing-primer family.
Oligos and identifiers
π’ Mahat 2016 Table 1 prints these predecessor oligos:
- VRA3:
5β²-pGAUCGUCGGACUGUAGAACUCUGAAC-/Inverted dT/-3β². - VRA5:
5β²-CCUUGGCACCCGAGAAUUCCA-3β², unphosphorylated at its 5β² end. - RP1, for RT and PCR:
5β²-AATGATACGGCGACCACCGAGATCTACACGTTCAGAGTTCTACAGTCCGA-3β². - RPI-n:
5β²-CAAGCAGAAGACGGCATACGAGATNNNNNNGTGACTGGAGTTCCTTGGCACCCGAGAATTCCA-3β². Its six Ns are a sample index, not the optional ChRO molecule identifier.
π’ The ChRO article says some libraries have a molecule identifier in the first six sequenced bases. Original Table 1 actually marks samples, including UMU94-13_leChr, GBM-88-04_Chr and PDX-88-04_P57, among others. Marks vary between replicate/subsample rows. Blank cells and combined rows do not define an immutable ordered adapter identity. The previous statement that sample membership was undocumented was incorrect.
The public page lists predecessor sequences without assigning them unchanged to every ChRO sample. The endpoint retains molecular roles while exact study-specific adapter arms, UMI-bearing variants, primer sites and run masks remain open model questions. This does not assert that those details were never published.
Bounded pass 2026-10-17 (round 08)
Re-read article Methods lines 148β158 and Supplementary Table 1 (MOESM3 sheet 1 header and UMI column), and Mahat 2016 procedure steps 55β82 (second/third enrichments repeat steps 23β48, including the Trizol release from beads; the 5β² ligation reuses the step-52 ligation mix). The graph order agreed with these passages. The run-on and hydrolysis condition labels were completed from Methods line 154. The ChRO article does not name the 5β²-adapter ligase, the adapter/primer variants, PCR cycles or read lengths; these remain open model questions. This is not a claim that they were never published.
Remaining source obligations
Reference 27 is Wuarin and Schibler's 1994 chromatin-isolation method; reference 28 is the 2016 PRO-seq protocol. The article also directly links GSE117832 and the Danko-Lab PRO-seq processing pipeline. The review ledger records actual original-source retrieval and reading scope. An unspecified manufacturer protocol is an unresolved source identity, not an invented unavailable document. Full supplementary visual/result-table scope and relevant linked material still require bounded dispositions and independent original readings. No missing-information claim is accepted at this checkpoint.