CirSeq — circular resequencing of RNA virus populations
Protocol relationships
Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
Short viral RNA fragments are circularized and copied repeatedly by rolling-circle reverse transcription, placing at least three linked template copies inside one Illumina read.
The original protocol names TruSeq indexed adapters and PCR primer cocktail FC-121-4001, but this model has not reconstructed the complete historical adapter/primer species. Step 43 states 135 combined adapter bases; the former generic canonical shell did not match that source value and is no longer used. The 2015 kit guide is a comparator: it lists six reported index bases plus a seventh adapter base and a 3′-T ligating end, without establishing full 2014 lot equivalence. The native graph retains the original RNA 85–100-nt window and the recommended 300-nt single-read profile, with primer sites unassigned.
Reaction workflow
PAGE-purified CirSeq library
Fragment viral RNA with Zn2+. Inputs: Zn2+ fragmentation condition
Select 85–100-nt RNA fragments. Inputs: 85–100-nt size-selection rule. Other outputs: RNA outside the 85–100-nt window → discard
Circularize RNA fragments. Inputs: T4 RNA ligase 1 with 1 mM ATP
Random-prime rolling-circle reverse transcription. Inputs: random hexamers (Invitrogen N8080127); SuperScript III reverse transcriptase; RNase H (added after 2 min at 42 °C)
Synthesize the second cDNA strand. Inputs: NEBNext second-strand synthesis enzyme mix (E6111)
Blunt the double-stranded cDNA. Inputs: NEBNext end-repair enzyme mix
Add one 3-prime dA to each cDNA end. Inputs: Klenow fragment (3′→5′ exo−)
Present adapter and substrate ends. Step 31 dA-tails the cDNA and Step 35 ligates TruSeq indexed adapters. The later 2015 FC-121-4001 guide confirms a 3′-T family end, but complete historical adapter identity/revision has not been assigned. The native graph does not import a canonical Y-stem or later primer shell.
Ligate TruSeq indexed adapters. Inputs: historical TruSeq indexed adapters (FC-121-4001); complete species unassigned; NEBNext Quick T4 DNA ligase
Excise 450–600-nt adapter-ligated DNA (Steps 36–45). Inputs: 10% urea-PAGE excision of 450–600-nt ligated DNA. Other outputs: ligation products outside the excised 450–600-nt band → discard
Amplify 15 cycles with Phusion (Steps 46–47). Inputs: TruSeq PCR primer cocktail (FC-121-4001), P5-side member; TruSeq PCR primer cocktail (FC-121-4001), P7-side member; Phusion high-fidelity DNA polymerase
Gel-purify the amplified library (Steps 48–53). Inputs: 7.5% native PAGE excision. Other outputs: amplified DNA outside the excised band → discard
Other material outcomes
RNA outside the 85–100-nt window — discard
does not fit at least three linked copies within the long read
Molecular structure is not represented in this graph.
ligation products outside the excised 450–600-nt band — discard
left in the urea-PAGE gel; excised fragments must be at least 435 bases (135 adapter bases plus at least 300 insert bases)
Molecular structure is not represented in this graph.
amplified DNA outside the excised band — discard
left in the 7.5% PAGE gel (Step 52 repeats Steps 42–44)
Molecular structure is not represented in this graph.
Final sequencing library
TruSeq adapters flank a double-stranded cDNA insert containing tandem copies of one circular RNA fragment.
Sequencing entry
The selected source recommendation uses a 300-nt single read; the current model has not reconstructed the historical TruSeq primer/adapter sites.
Sequencing limitation. The selected recommended MiSeq profile uses single 300-nt reads to contain tandem copies; the exact historical sequencing primer/site is not reconstructed. No paired Read 2 or index acquisition is assigned from a canonical adapter shell.
Sequencing-primer binding on the final library
Read content and handling
Exact read placement is unresolved: The selected source recommendation uses a 300-nt single read; the current model has not reconstructed the historical TruSeq primer/adapter sites.
Read
Cycles
Content
Include in sequence analysis?
Read 1
300
sample index, historical TruSeq left adapter; exact species unassigned, tandem-repeat cDNA, source dA junction, historical TruSeq right insert-facing arm; unassigned, other library regions (read orientation and cycle boundaries unresolved)