CROP-seq

1. What it is

CROP-seq makes a pooled CRISPR guide detectable in the same 3′ single-cell RNA-seq library that measures the cell's transcriptional response. The defining implementation used Drop-seq.

Defining paper: Datlinger et al., “Pooled CRISPR screening with single-cell transcriptome readout,” Nature Methods (2017), doi:10.1038/nmeth.4177.

2. Sources read

3. The vector operation

🟢 The paper places the hU6–guide cassette in the 3′ long terminal repeat of a self-inactivating LentiGuide-Puro derivative. A packaged transfer RNA has R–U5 at its 5′ end and U3–R at its 3′ end. During reverse transcription, the 3′ U3 rebuilds both integrated U3–R–U5 LTRs. The cassette inserted with that U3 is therefore duplicated.

This is represented by lib/lentivirus.py: callers supply U3 once, and the integrated provirus constructor derives both copies. Equality is a construction rule, not a repeated test.

🟢 The downstream copy becomes part of the polyadenylated puromycin-resistance RNA polymerase II transcript, while hU6 independently produces the functional, non-polyadenylated RNA polymerase III guide. One DNA cassette creates two overlapping RNAs.

4. Guide cloning junction

🟢 The Supplementary Protocol gives each pooled 74-nt ssDNA oligo as:

5'-TGGAAAGGACGAAACACCG-[20-nt guide]-GTTTTAGAGCTAGAAATAGCAAGTTAAAATAAGGC-3'

The 5′ prefix provides 18 bases of hU6 homology and adds G as the constant first base for U6 transcription. The 35-base postfix is homologous to the guide backbone. The oligo pool is assembled into the 8,333-bp BsmBI-digested backbone by Gibson/NEBuilder assembly. For individual guides, the paper instead gives phosphorylated CACCG(N)20 / AAAC(N)20C oligos and BsmBI ligation.

🟢 The deposited empty 10,214-bp vector map contains a 1,885-bp filler between hU6 and the guide scaffold; the BsmBI sites remove it. That filler belongs to the empty cloning backbone, not a guide-bearing viral construct.

5. Single-cell library

🟢 Cells and Drop-seq barcoded beads are co-encapsulated. Polyadenylated RNAs are captured by bead oligo-dT, reverse-transcribed with template switching, SMART-PCR amplified, tagmented with Nextera XT, and selectively enriched with New-P5-SMART and N70x primers. The authors use more cDNA at tagmentation to favor larger fragments and increase the chance that a fragment retains the guide.

🟢 Ordered oligos printed in the protocol include:

TSO:                 AAGCAGTGGTATCAACGCAGAGTGAATrGrGrG
SMART PCR primer:    AAGCAGTGGTATCAACGCAGAGT
New-P5-SMART hybrid: AATGATACGGCGACCACCGAGATCTACACGCCTGTCCGCGGAAGCAGTGGTATCAACGCAGAGT*A*C
Custom Read 1:       GCCTGTCCGCGGAAGCAGTGGTATCAACGCAGAGTAC

🟢 Section 10.3 ("SMART PCR to enrich cDNA library") runs the bead cDNA amplification with one oligo — the SMART PCR primer at 0.8 µM in 2× KAPA HiFi HotStart ReadyMix, 4 cycles at 65 °C annealing then 10 at 67 °C. Both ends of the template-switched cDNA carry the same handle, so no second primer exists; an earlier version of the model declared a forward/reverse pair, which has been corrected to a single symmetric primer species.

🟢 Section 11.1 tagments at 55 °C for 5 min and then stops the reaction with Nextera XT Neutralization Buffer (5 min, room temperature) before the enrichment PCR; the graph now carries that quench as its own step. 🟢 Section 11.2's enrichment master mix pairs the New-P5-SMART hybrid oligo with the indexed Nextera N70X oligo in Nextera PCR mix. 🟡 The hybrid oligo's two 3'-terminal phosphorothioate linkages (…AGT*A*C) are recorded in the module comment; the model string carries bases only.

🟢 The run is 20 bases Custom Read 1, 8 bases Index 1, and 64 bases Read 2. Read 1 is the 12-base cell barcode plus 8-base UMI. Read 2 supplies transcript sequence and identifies guide-bearing molecules when it crosses the guide.

6. Separate pooled-library QC readout

🟢 The protocol also gives a one-PCR Illumina library for guide-pool QC or classical pooled-screen genomic-DNA readout. Its staggered i5-side primer ends after the CACCG cloning junction, so Read 1 starts at guide base 1. This is not the cell-barcoded Drop-seq library and is intentionally separate from the main schematic.

7. Boundary of this page

🟢 The CROP-seq Supplementary Protocol lists the TSO, SMART PCR, selective enrichment, and custom Read 1 oligos, but refers to prepared Drop-seq beads rather than printing their full barcoded capture oligo. The original inventor lab's Drop-seq protocol v3.1, primer table on PDF p. 3 (extracted lines 117–150), prints the inherited SeqB bead family, summarized here as: 5′-Bead–Linker–TTTTTTTAAGCAGTGGTATCAACGCAGAGTAC-J12-N8-T30-3′, where the 12 J positions are the bead-specific cell barcode and the 8 N positions are a per-oligo UMI. It also prints the Drop-seq TSO, SMART PCR primer and custom Read 1 primer. 🟡 CROP-seq does not identify which exact barcode members were present in the prepared bead batch; the graph therefore records the bead reagent as a family.

This page documents original CROP-seq and its Drop-seq readout. Later dedicated guide-capture, 10x Feature Barcode, and multi-perturbation chemistries are separate protocols.