Digest genomic DNA with two enzymes, ligate end-selective adapters carrying an inline sample barcode, pool and size-select, then add the Illumina outer adapter and a second sample index by PCR.
The displayed GCATG inline barcode and ATCACG i7 are examples from published Sequences S1. This graph follows the route without optional biotin-P2 capture; same-end products are not physically removed at digestion. Protocol S1 says P1/P1 products can amplify but do not cluster. Their downstream recovery is unresolved here. The primer sites show compatibility with single- or paired-end sequencing, with or without an index read; no single acquired cycle recipe is assigned.
Digest genomic DNA with EcoRI-HF and MspI. Inputs: EcoRI-HF; MspI
Present adapter and substrate ends. The published P1 and P2 adapter overhangs are validated against the EcoRI and MspI cut-derived cohesive ends.
Ligate end-selective P1 and P2 adapters. Inputs: barcoded P1 and P2 cohesive-end adapters; T4 DNA ligase. Other outputs: same-end adapter-ligated fragment classes → unresolved
Pool and select the intended fragment-size window. Inputs: narrow gel size-selection interval. Other outputs: off-size ligation products → discard
Complete the outer arms and add the i7 index. Inputs: P5-side library PCR primer; indexed P7-side library PCR primer; Phusion DNA polymerase
Other material outcomes
same-end adapter-ligated fragment classes — unresolved
Protocol S1, optional streptavidin-removal section: P1/P1 products can amplify but do not cluster. Optional biotin-P2 capture is not selected here; same-end products may persist through downstream size selection/PCR. This compact graph does not reconstruct their recovery or amplification.
Molecular structure is not represented in this graph.
off-size ligation products — discard
off-size fragments are excised away
Molecular structure is not represented in this graph.
Final sequencing library
A P1–insert–P2 molecule after PCR. Read 1 encounters the inline barcode before the EcoRI-associated genomic end; Index 1 reports i7, and Read 2 enters from the MspI-associated end.
Sequencing primers
Standard TruSeq Read 1, Index 1 and Read 2 primers bind. Demultiplexing uses the inline P1 barcode together with the optional six-base i7.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
anneals to the top strand over Read 2 site start, Index 1 / Read 2 arm
CGxxxxxxxxxx… (from MspI remnant)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
not fixed
sample index (cycles 1–5); EcoRI remnant (cycles 6–9); size-selected genomic insert (from cycle 10; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Index 1 (i7)
not fixed
sample index (cycles 1–6)
No — use for sample demultiplexing
Index 2 (i5)
—
not acquired
No — not sequenced
Read 2
not fixed
MspI remnant (cycles 1–2); size-selected genomic insert (from cycle 3; molecule-dependent length); short molecules may read through into the opposite library end