Digital Telomere Measurement (DTM)

1. What it is

DTM ligates barcoded capture/tether duplexes directly to native human telomeres, fills the terminal gap and measures individual telomeres by Oxford Nanopore sequencing.

2. Sources read

3. Construct and reaction order

Methods, "Telomere capture sequencing nanopore library preparation" (s41467-024-49007-4_PMC11189511.xml.txt:158):

  1. 🟢 Equimolar barcoded capture oligo and seqTether are duplexed in low TE (95 °C 2 min, then 1 h at room temperature).
  2. 🟢 About 3 µg HMW genomic DNA is ligated to freshly duplexed capture oligos (rCutSmart, 25 pmol duplex, 4000 U T4 DNA ligase, 0.1 mM ATP added) overnight at 37 °C, then heat-inactivated at 65 °C for 10 min.
  3. 🟢 In the same tube, Sulfolobus DNA polymerase IV (4 U, ThermoPol, dNTPs, ATP; 56 °C 2 min then 72 °C 15 min) fills "potential gaps between the capture oligo and the double-strand/single-strand junction".
  4. 🟢 ProNex beads (1.6×), two 80% ethanol washes, elution in 60 µL ONT elution buffer give the "post-capture sequencing library".
  5. 🟢 The whole post-capture library is ligated to the ONT sequencing adapter (AMII for R9, NA for R10) with Quick T4 DNA ligase for 1 h at room temperature; the rest follows the whole-genome LSK-110 workflow. Multiplexed runs pool up to eight differently barcoded post-capture libraries (1000 ng total) before adapter ligation (not drawn).

🟡 Which nick T4 ligase seals is not stated. By polarity, the capture oligo annealed to the G-rich overhang has its 3′ end (CCTAACC) facing the C-rich 5′ terminus and its 5′-phosphorylated end distal, paired with seqTether. Fig. 1a draws the CCAATCC (3′→5′) arm abutting the C-rich strand and seqTether opposite the G-strand terminus, but is schematic. Before the 2026-10-17 bounded pass the page claimed that ligase "joins the capture 5′ phosphate at the native C-rich terminus"; that is geometrically impossible and was a model error, now removed.

🟢 Supplementary Data 3 gives seqTether as AACCTTGGAGATGCACGGAGCAAGCAAT and the representative 5′-phosphorylated p-t3-nb01 capture oligo as TGCTCCGTGCATCTCCAAGGTTCACAAAGACACCGACAACTTTCTTCCTAACC. 🟡 The table does not partition the oligos. Comparing its rows gives a 22-nt tether-complementary arm (shared prefix of all eight canonical oligos; its reverse complement is the first 22 nt of seqTether), a 24-nt barcode and a 7-nt CCTAACC telomere arm (shared suffix of the canonical oligos; the seven TSQ variants share the first 46 nt with p-t3-nb01 and differ only in the last 7). The model previously split this as 25 + 6; that was a repository error, corrected 2026-10-17, and tools/selftest.py now derives the partition from the table. Eight canonical-telomere barcode variants and seven telomere-sequence-variant capture oligos are provided; the page uses p-t3-nb01 as the representative molecule.

🟢 The core Methods used high-molecular-weight DNA directly. The paper discusses later/optional restriction-digest refinements, but the page no longer invents a mechanical-fragmentation step.

4. Final library and sequencing

A motor-loaded nanopore adapter feeds an intact tagged strand through the pore; no sequencing primer binds.

🔴 The defining Methods identify the historical adapters as AMII for R9.4.1 and NA for R10.4, but neither the paper nor its supplementary files print their complete motor-bearing assemblies. ONT's current chemistry document now prints current LA/NA oligonucleotide strands; it does not establish that those current sequences are the same reagents used with LSK-110 in this study. The page therefore does not backfill a later adapter sequence into the historical library.

🟢 The Methods also link the authors' Telometer repository. The now-cached gh_TelometerLibraryPrep.docx.txt identifies itself at line 2 as “04/2025”. This is a later author protocol, rather than the defining 2024 preparation. This migration inspected its identity only; its digestion, polymerase and kit choices are excluded from the 2024 graph. The earlier failed-download statements in historical review passes describe those passes, not its present availability.

5. Bounded native graph migration (2026-10-18, batch 12)

Inspected three originals: published Methods s41467-024-49007-4_PMC11189511.xml.txt:150–160 (whole-genome workflow incorporated by reference and capture-specific overrides), Supplementary Data 3 s41467-024-49007-4_supp_41467_2024_49007_MOESM6_ESM.xlsx.txt:1–23 (oligos and modifications), and the identity header of the April 2025 author DOCX gh_TelometerLibraryPrep.docx.txt:2. Ran the mandatory bundle oligo scraper and checked its published-table hits directly. Superseded preprint chemistry and later author-protocol chemistry did not supply this graph.

The protocol now owns its native graph. Capture and seqTether enter as independent source-exact polymers, then form a computed antiparallel duplex. The capture/tether material is allocated once to the chromosome-end hybrid; the following ligation consumes that complex, rather than consuming the same capture aliquot again. The capture 5′ phosphate is an input modification, not a base copied onto a new strand. The sample barcode has structured sample-index identity. The drawn telomere lengths and repeat register are schematic, not measured properties of a native chromosome end.

The inspected Methods do not resolve the sealed capture nick sufficiently for this model to construct its covalent product. Post-ligation and post-gap-fill states therefore carry explicit unresolved assembly tokens instead of claiming the unchanged pre-ligation chromosome is the product or choosing a covalent connection. The gap-fill tract and historical AMII/NA motor geometry remain unassigned. These are model limits of this bounded reading, not accepted source-absence claims. No PCR or amplification is introduced.

Both source-described ProNex cleanups are explicit: 1.6× after gap filling and 1.1× after motor-adapter ligation, the latter following the whole-genome workflow incorporated by reference. Each keeps the eluate and physically discards supernatant/washes. Cleanup does not claim complete removal of untagged chromosomes or any other specific molecular class. No computational read rejection is modelled as physical removal. The complete 60-µL post-capture eluate enters adapter ligation. No aliquot split or sample pool is invented.

Deferred: the up-to-eight-sample 1000-ng multiplex pool; native end heterogeneity and sealed capture connectivity; exact Pol-IV tract; historical AMII/NA assembly; and full reading of the later April 2025 author protocol as a separate variant. Existing blocked missing-information status is unchanged. This capped migration is not a complete protocol source review.

Code review corrections (2026-10-18; no additional source reading)

The reviewed source inventory is now an explicit curator-written list rather than automatic enumeration of graph nodes. Post-ligation, gap-filled and motor-ligated populations retain the source barcode as an unplaced structured segment with capture_sample sample-index identity. This metadata assigns neither a covalent attachment nor a sequence coordinate within the unresolved assembly; it is not drawn as a separate free oligo. Cleanup preserves it.

The same populations retain independent possible residual classes: unreacted genomic DNA, partially capture-adapted DNA, free capture and free/incompletely incorporated seqTether; after motor ligation, captured DNA without motor and free/incompletely attached motor adapter are also retained. These classes are inferred possibilities, not observed products or proportions. They remain possible in bead-cleanup eluates because cleanup has not established their complete removal. Their structured candidate status does not convert a computational filter into physical removal. NICK_SEALING classifies the source-stated ligation within the already assembled complex only; its structured geometry explicitly declines to assign any particular sealed nick.