No curated ancestry links yet. This does not establish independent origins.
No formal ancestor assigned in this review. Considered SNARE-seq, Drop-seq, DOGMA-seq as discovery candidates, but cannot verify child chemistry/version from an applicable original; shared facets or names alone cannot justify even a chemistry-analogy edge.
Machine vision and multilayer valves deterministically co-encapsulate one low-input cell and one mRNA-capture bead; captured RNA is reverse-transcribed with template switching on barcoded beads, amplified by SMART PCR and tagmented into a 3′ RNA-seq library.
Source scope. The reaction steps, printed oligos and read lengths come from the authors' step-by-step protocol, which describes itself as their most up-to-date version; the defining Nature Methods Methods section was not available, so equivalence with the published experiments (for example cDNA and library PCR cycle numbers) is not established. The capture-bead oligo, the Tn5 p7|ME adapter, the i7 index primer and the Read 2/index primers are not printed in the inspected sources; they are drawn as named roles, and the two PCR geometries are recorded as unavailable.
Key oligos
Template Switch Oligo: 5′-AAGCAGTGGTATCAACGCAGAGTGAATrGrGrG-3′ (rGrGrG = three 3′ riboguanosines; 2.5 µM final in RT)
All four as printed on p. 2 (Required primers) of the author protocol. The i7 index primers are cited there only as Buenrostro et al., Nat. Methods 10, 1213 (2013); no bases are printed.
Reaction workflow
DisCo sequencing library
Position exactly one cell and one bead. Inputs: machine-vision valve positioning condition. Other outputs: empty or mis-paired valve events → discard
Co-eject the pair and sort the droplet to the sample outlet. Inputs: co-ejection and droplet-sorting condition. Other outputs: droplets routed to the waste outlet → discard
Recover beads on the cp-chip and wash (6X SSC, RT buffer). Inputs: bead-capture (cp) chip pillars; 2x 6X SSC and 1x RT-buffer washes. Other outputs: oil, stuffer droplets and wash flow-through → discard
Reverse-transcribe on the cp-chip, 42 °C 90 min. Inputs: bead oligo(dT) primer carrying cell barcode and UMI (sequence not in inspected sources); Maxima H− reverse transcriptase (Maxima 5x RT buffer, Ficoll PM-400, dNTPs, RNase inhibitor)
Wash beads on chip after RT. Inputs: TE-SDS once, TE-TW twice, 10 mM Tris once. Other outputs: RT mix including free TSO, RNA and enzyme → discard
Exonuclease I treatment on chip. Inputs: Exonuclease I (10X Exo I buffer), 37 °C 45 min. Other outputs: nucleotides from unextended single-stranded bead oligos (expected Exo I substrate; purpose not stated in protocol) → discard
Wash and elute beads from the cp-chip. Inputs: TE-SDS, 2x TE-TW, water washes; elute beads from cp-chip with water; pellet. Other outputs: Exo I mix and wash supernatant → discard
Separate the PCR supernatant from the capture beads. Inputs: spin down capture beads and transfer the PCR supernatant. Other outputs: capture beads retaining bead-bound strands → discard
0.6x AMPure cleanup. Inputs: 0.6x AMPure beads. Other outputs: fragments below ~200 bp and primers → discard
Tagment cDNA with p7|ME-loaded Tn5. Inputs: Tn5 loaded with p7|ME (bases not printed); in-house Tn5 (Picelli et al. 2014), 5x TAPS, 55 °C 6 min, 2 ng cDNA
Stop tagmentation with SDS. Inputs: 1.5 µL 0.2% SDS, RT 5 min
72 °C 3 min, 98 °C 30 s, then 16 cycles (63 °C anneal) with P5 SMART PCR + i7 index primer. Inputs: P5 SMART PCR (two 3′ phosphorothioates); i7 index primer (Buenrostro et al. 2013 set; bases not printed); KAPA HiFi polymerase, 5x buffer, dNTP
0.7x AMPure XP cleanup; BioAnalyzer/Fragment Analyzer. Inputs: 0.7x AMPure XP. Other outputs: short products and primers → discard
Other material outcomes
empty or mis-paired valve events — discard
fails deterministic one-cell/one-bead positioning
Molecular structure is not represented in this graph.
droplets routed to the waste outlet — discard
does not reach the sample outlet
Molecular structure is not represented in this graph.
oil, stuffer droplets and wash flow-through — discard
flows through the bead-capture chip
Molecular structure is not represented in this graph.
RT mix including free TSO, RNA and enzyme — discard
washed off the cp-chip
Molecular structure is not represented in this graph.
nucleotides from unextended single-stranded bead oligos (expected Exo I substrate; purpose not stated in protocol) — discard
removed by the TE-SDS / 2x TE-TW / water washes that follow Exo I on the chip
Molecular structure is not represented in this graph.
Exo I mix and wash supernatant — discard
supernatant removed before PCR
Molecular structure is not represented in this graph.
Molecular structure is not represented in this graph.
fragments below ~200 bp and primers — discard
left in the 0.6x supernatant
Molecular structure is not represented in this graph.
short products and primers — discard
left in the 0.7x supernatant
Molecular structure is not represented in this graph.
Final sequencing library
Selected bead-end product: P5 SMART PCR primer (printed) — bead-derived cell barcode, UMI and poly(T) (bases not printed) — cDNA — Tn5 p7|ME end and i7 index (bases not printed).
Sequencing primers
NextSeq, following Drop-seq specifications (author protocol, Sequencing Strategy): Read 1 = 20 bp primed by the custom Drop-seq SeqB primer; Read 2 = 50 bp. The SeqB site is computed on the printed P5 SMART PCR end.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
Sequencing primers on the final library
Read
Primer
Sequence
Lands on
First bases read
Read 1
Custom Drop-seq SeqB sequencing primer Bues, Biocanin, Pezoldt et al., DisCo step-by-step laboratory protocol (EPFL Deplancke lab, PDF 14 Sep 2021; https://www.epfl.ch/labs/deplanckelab/wp-content/uploads/2021/09/DisCo_protocol.pdf), p. 2 Required primers and Sequencing Strategy
5'-GCCTGTCCGCGGAAGCAGTGGTATCAACGCAGAGTAC-3'
anneals to the bottom strand over spacer, SMART handle, primer 3′ AC
… (from cell barcode)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
20
cell barcode (from cycle 1; length not stated); then UMI (cycle boundary unresolved)