DISCOVER-Seq — MRE11 ChIP-seq at CRISPR cleavage sites
Protocol relationships
Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. The scoped inferred predecessor is the most plausible earlier declared design given the inspected mechanism and chronology; no formal descent is asserted.
MRE11 recruited to newly cut chromosomal DNA is fixed in place and immunoprecipitated; ordinary paired-end ChIP-seq then preserves the sharp genomic endpoints that BLENDER recognizes as nuclease cuts.
INFERRED — canonical TruSeq library arms illustrate kit-compatible primer sites; they do not identify the supplied PCR Primer Cocktail sequences. DISCOVER-Seq does not use a custom capture oligo or UMI. Its defining implementation delegates library construction to the now-discontinued single-index TruSeq ChIP kit; index identities are public, while the exact supplied oligos remain unassigned in this model.
The detailed protocol states two chromatin-size windows.
Wienert et al., Nature Protocols (2020), PMC7305837 'Sonication' overview, line113: chromatin sheared to a fragment size of approximately 150–500 bp
Same article, 'Anticipated results', line994 (and the authors' protocols.io v2, step note, line292): sheared chromatin should have a median size of 200–500 bp (gel smear 200–500 bp)
Modelled: The model leaves the exact shearing window unassigned and draws the fragments as 'a few hundred base pairs'. Evidence: Both passages are printed in the same original author protocol; neither is a text-extraction artefact, and the authors state that sonication must be optimized per cell type and sonicator. Remaining uncertainty: Whether 150–500 bp is an informal restatement or a different acceptance window is unresolved; no single numeric range is attributed to the sequenced libraries.
Key oligos
TruSeq ChIP AR001 sample index example — 5′-ATCACG-3′
PCR Primer Cocktail PN15026786: physical oligo sequences not established in this model.
Reaction workflow
INFERRED — canonical-arm DISCOVER-Seq library
Recognize MRE11 at newly made DNA breaks. Inputs: endogenous MRE11 repair protein. Other outputs: chromatin without captured MRE11-bound ends → unresolved
Cross-link MRE11–DNA complexes. Inputs: 1% formaldehyde, 15 min at room temperature, quenched with 125 mM glycine
Sonicate fixed chromatin. Inputs: Covaris S2 sonication of lysed nuclei
Immunoprecipitate MRE11-bound chromatin. Inputs: Protein A magnetic beads; anti-MRE11 antibody (Novus NB100-142 or Abcam ab208020) on Protein A Dynabeads. Other outputs: MRE11-depleted ChIP flow-through → discard
Reverse cross-links and remove protein. Inputs: 65 °C cross-link reversal (≥6 h), RNase A, proteinase K and MinElute recovery
Enrich adapter-ligated ChIP DNA with PPC PN15026786. Inputs: TruSeq ChIP PCR Primer Cocktail forward component; TruSeq ChIP PCR Primer Cocktail reverse component; TruSeq ChIP PCR Master Mix PMM PN15026785
Other material outcomes
chromatin without captured MRE11-bound ends — unresolved
MRE11-negative chromatin is not physically separated before fixation. Its later ChIP recovery is not resolved by this representative MRE11-bound branch.
Molecular structure is not represented in this graph.
MRE11-depleted ChIP flow-through — discard
is not retained by MRE11 immunoprecipitation
Molecular structure is not represented in this graph.
Pooled-library cleanup and size expectation. The detailed protocol pools equal amounts of the individual TruSeq ChIP libraries, removes adapter dimers with 0.8× AMPure XP beads (repeating or using PippinPrep/gel if dimers persist) and expects a 300–500 bp mean library size. Adapter-dimer species are therefore an acknowledged by-product, and only their bead-based removal is represented as a physical separation.
Final sequencing library
INFERRED — canonical TruSeq arm model. Either genomic orientation can be captured. One library strand is shown from a random sonication boundary through MRE11-enriched DNA to the cellular nuclease-cleavage boundary; the six-base i7 sample index comes from the historical TruSeq ChIP adapter.
Sequencing primers
The detailed protocol specifies 100-bp paired-end sequencing on a HiSeq 4000, NovaSeq or similar instrument at roughly 30–40 M read pairs per ChIP sample. Standard TruSeq Read 1, Index 1 and Read 2 primers bind the final library; paired fragment endpoints, not a barcode read, provide the cut-site signal.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
anneals to the top strand over dA junction, Index 1 / Read 2 arm
… (from MRE11-bound genomic DNA from a Cas9 cut to a random sonication end)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
100
MRE11-bound genomic DNA from a Cas9 cut to a random sonication end (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Index 1 (i7)
6
sample index (cycles 1–6)
No — use for sample demultiplexing
Index 2 (i5)
—
not acquired
No — not sequenced
Read 2
100
MRE11-bound genomic DNA from a Cas9 cut to a random sonication end (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end