Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
Downstream adaptor boundary. The paper publishes the barcode adaptor, SC-PCR primers, restriction steps and read coordinates, but not the Illumina adaptor or library-primer sequences. Those outer final-library regions are dotted placeholders rather than a guessed TruSeq construct.
Published source discrepancies. Fig. 3A calls the barcode adaptors 64 bp, while Supplementary Table 2 lists 1,152 forward strands of 60 nt; the model uses the listed sequences and cannot establish a four-base extension. Online Methods calls the BciVI product a 5′-end A overhang, while the cut geometry of the printed BciVI motif yields a 3′-A overhang in the model. The intended published end orientation remains uncertain.
Published Supplementary Fig. 2A pairing discrepancy. In the original publisher PDF, page 2, the top green priming blocks are GGGGGACC and GGTGGGGG, while both lower rows print GGGGGTGG and CCAGGGGG. Those lower strings do not pair with the top; their complements would be CCCCCTGG and CCACCCCC. Supplementary Table 2 supplies the 1,152 forward oligos with the top-strand constant, so this model uses a listed top strand and computes its complement. The intended lower figure motifs remain uncertain. Fig. 2B labels the outer ends only “Illumina adapter”, leaving those bases unresolved.
The published 60-nt strand and its derived complement. The same 8-nt identity is encoded at both ends, with the second copy reversed.
Reaction workflow
Drop-ChIP final library, authoritative boundary
End-repair nucleosomal DNA. Inputs: DNA end-repair enzymes
Present adapter and substrate ends. The defining source prints the double-stranded barcode adapter and specifies blunt ligation to end-repaired nucleosomal DNA.
Blunt-ligate barcode adapters to both fragment ends. Inputs: published symmetric barcode adapter; DNA ligase
Remove concatemers and outer adapter halves with PacI. Inputs: PacI restriction enzyme
Elute, remove nucleosomes and recover DNA before SC-PCR. Inputs: Proteinase K after elution and RNase treatment (recovery summarized)
Amplify the PacI-trimmed barcode-labelled fragment: 14 SC-PCR cycles. Inputs: published SC-PCR1 primer; published SC-PCR2 primer; SC-PCR and library PCR polymerase
Dephosphorylate SC-PCR products before BciVI. Inputs: Antarctic Phosphatase
Remove SC-PCR ends and expose 3′-A overhangs with BciVI. Inputs: BciVI type-IIS restriction enzyme
Present adapter and substrate ends. The source establishes adapter ligation; selected Illumina adapter bases and end geometry remain unresolved from the checked article and supplements.
Ligate Illumina adapters to the 3′-A-ended insert. Inputs: unresolved Illumina adapter; DNA ligase
PCR-complete the Illumina library: 14 cycles. Inputs: unresolved library PCR-primer pair; SC-PCR and library PCR polymerase
Read layout
Sequencing-primer binding on the final libraryPublished barcode coordinates and Supplementary Fig. 2B read boundaries: collected Read 1 begins at the barcode after the 11-nt constant; Read 2 includes that constant before its barcode. The Methods states 11 initial dark cycles but does not specify their per-read run setup.
Read
Published layout
Read 1
8-nt cell barcode at bases 1–8, then TTAA and genomic DNA
Read 2
11-nt constant, 8-nt cell barcode at bases 12–19, then TTAA and genomic DNA
Index
sample index distinguishes the pooled library; selected sequence unresolved from checked article and supplements
Read content and handling
Original Sequencing Methods specify 2 × 60 bp and 11 initial dark cycles; their per-read setup and exact outer primer assignments remain unverified. No index-read acquisition is assigned in this pass.
Read
Cycles
Content
Include in sequence analysis?
Read 1
60
8-nt cell barcode at cycles 1–8, TTAA, then genomic DNA
Yes — after extracting identifiers
Read 2
60
11-nt constant, 8-nt cell barcode at cycles 12–19, TTAA, then genomic DNA