Earth Microbiome Project ITS amplicon sequencing
1. What it is
The Earth Microbiome Project fungal ITS workflow amplifies ITS1 with primers that already contain complete Illumina arms and a twelve-base Golay sample barcode. Unlike the two-stage Illumina 16S workflow, this is a fusion-primer library and uses locus-specific custom sequencing primers extending beyond the PCR-primer boundary.
2. Authoritative source
🟢 Earth Microbiome Project, ITS Illumina Amplicon Protocol (EMP.ITSkabir), and the linked November 2016 ITS1f_ITS2 oligo workbook. The workbook publishes the fusion constructs and all three custom sequencing primers.
3. Published fusion primers
🟢 Forward ITS1f construct, 5′→3′:
AATGATACGGCGACCACCGAGATCTACAC GG CTTGGTCATTTAGAGGAAGTAA
This is the P5-side Illumina arm, a GG linker and ITS1f.
🟢 Reverse ITS2 construct, 5′→3′:
CAAGCAGAAGACGGCATACGAGAT NNNNNNNNNNNN CG GCTGCGTTCTTCATCGATGC
This is the P7-side arm, a twelve-base Golay barcode, a CG linker and ITS2. Spaces above only expose the published components.
🟢 Source discrepancy. The EMP ITS page, reverse-primer construct, and its 2018 protocols.io version, p. 4, show NNNNNNNNNN (10 bases). The linked November 2016 primer workbook, Reverse Primer Constructs sheet, lines 11–971 of the extracted text, lists 960 twelve-base Golay members. Smith and Peay 2014, Molecular methods, p. 3, also specifies a 12-base error-correcting Golay barcode and a 12-base index read. The model uses the ordering workbook’s 12 bases; whether the 10-N placeholder is shorthand or a distinct unlisted construct remains unknown.
4. Read geometry
🟢 Read 1: TTGGTCATTTAGAGGAAGTAAAAGTCGTAACAAGGTTTCC.
🟢 Read 2: CGTTCTTCATCGATGCVAGARCCAAGAGATC (V and R are degenerate positions).
🟢 Index 1: TCTCGCATCGATGAAGAACGCAGCCG.
These produce paired-end reads plus one custom index read over the twelve-base Golay barcode; there is no i5 read. For an exact computed landing, the schematic uses the valid Read 2 pool member V=G, R=A and labels that choice rather than treating it as inferred chemistry.
🟢 The cited Caporaso et al. 2012 Supplementary Methods, MiSeq preparation and sequencing protocol, describes a historical 16S run: 12 index cycles, custom Read 1/index/Read 2 primers in cartridge reservoirs 12/13/14, and 151×12×151 cycles (extracted lines 229–287). It recommends 15–30% PhiX for its 16S amplicons (lines 208–218); the later EMP ITS page advises 5–10% for ITS. The 2012 instrument settings are an example of how the custom-primer architecture was run, not a documented cycle/PhiX selection for every EMP ITS run.
4a. Amplification and pooling
🟢 EMP ITS page (retrieved 2026-10-17), PCR reaction mixtures, Thermocycler conditions and Amplification protocol; the same steps appear in the 2018 protocols.io version, pp. 6 and 10–11:
- 25 µl reactions: 13 µl water, 10 µl Platinum Hot Start PCR Master Mix (2x; 0.8x final), 0.5 µl each 10 µM primer (0.2 µM final), 1 µl template.
- 94 °C 1 min; 35 cycles of 94 °C 30 s, 52 °C 30 s, 68 °C 30 s; 68 °C 10 min; 4 °C hold (current web page table; the protocols.io thermocycler table is an image and was not transcribed).
- Each sample is amplified in triplicate and the replicates are pooled to 75 µl; samples are checked on an agarose gel, quantified with PicoGreen, and combined at 240 ng each.
- The pool is cleaned with the MoBio UltraClean PCR Clean-Up Kit; optionally half the pool is gel-extracted when spurious bands were seen. Its A260/A280 should be 1.8–2.0. The pool is then sent for sequencing with the three custom primers, and 5–10% PhiX is added.
🟢 Source discrepancy (amplicon size). The current EMP page gives "Amplicon size: ~250–600 bp (Bokulich & Mills, 2013; Hoggart et al., 2018)" under Thermocycler conditions, but "Expected band size for ITS1f-ITS2 is ~230 bp" in Amplification protocol step 3. The 2018 protocols.io version gives ~230 bp in both places. The model keeps the fungal insert as a variable placeholder and chooses neither value.
5. Scope
This page documents the fusion-primer EMP implementation, not every possible ITS region or primer pair. Primer choice remains taxon- and study-dependent.
Bounded pass 2026-10-17 (round breadth-first-09)
Re-fetched and read the EMP ITS web page and the 2018 protocols.io PDF; re-checked the workbook Forward and Sequencing Primers sheet rows 4–9 and the first Reverse Primer Constructs rows. The graph now names the Platinum Hot Start master mix and the cycling program, the triplicate PCR, equal-mass pooling and the UltraClean clean-up. The page shows the amplicon-size discrepancy. Workbook sheet labels were corrected; they were previously cited as non-existent "Read1/Read2/Index" sheets. Open questions: acquired cycle counts for EMP ITS runs (the page defers to Caporaso 2012, whose settings are for a historical 16S run); the 10-N versus 12-nt barcode discrepancy; Smith & Peay 2014 Figure S1 and Walters et al. 2016 Table S1 were not re-checked in this pass.