eccDNA Circle-Seq — research notes
Sources read
- 🟢 Møller et al. 2015, DOI 10.1073/pnas.1508825112, PMC4475933, full text and Methods.
- 2026-10-17 bounded pass: PMC article page text (Results "Circle-Seq, A Method for Genome-Scale Detection of eccDNA"; Methods "Purification and enrichment", "Digestion of remaining linear DNA", "Amplification", "PCR", "Sequencing", "Mapping of Reads"). Not read: SI Appendix PDF and Datasets S1–S3 (PMC download gate; URLs in the source manifest), Plasmid Mini AX, REPLI-g Mini and Apollo 324 vendor documents, and the cited plasmid-purification predecessors (refs 26, 27).
- 2026-10-17 follow-up retrieval (round deferred-followup-02), SI still not obtained: PMC
bin/pnas.201508825SI.pdfreturns the JavaScript "Preparing to download" gate; PMC Cloud has noPMC4475933prefix; Europe PMCsupplementaryFilesis empty,fullTextXMLreturns HTTP 500 and itsbin/route HTTP 403; the PNASsuppl_file/pnas.201508825si.pdfroute is behind Cloudflare (HTTP 403); OpenAlex/Unpaywall list only PMC and a University of Copenhagen research-portal record with no file. ENA PRJEB6368 run metadata givelibrary_construction_protocol"eccDNA purification" only (HiSeq 2000, SINGLE). Takara's current PrepX DNA Library Protocol-At-A-Glance documents (2018/2019) exist, but the paper names no Apollo kit and those revisions postdate the work, so they were not used. Manual URL: https://www.pnas.org/doi/suppl/10.1073/pnas.1508825112/suppl_file/pnas.201508825si.pdf - 2026-10-17 round deferred-followup-03: the maintainer hand-downloaded the published PNAS article PDF (
pnas.1508825112.pdf, printed doi:10.1073/pnas.1508825112, Møller et al.) and the SI Appendix (pnas.1508825112_pnas.201508825si.pdf, header "Supporting Information Møller et al. 10.1073/pnas.1508825112", 10 pages). Read: article Results "Circle-Seq, A Method…" (.txtlines 280–327), Fig. 1 legend (270–271), Materials and Methods "Strains and Plasmids" through "Mapping of Reads" (700–788) and PCR (771–777, 894–913); SI Appendix in full (Figs. S1–S10 legends, Dataset S1–S3 legends, lines 1–147). The SI contains figure legends and dataset descriptions only, no additional library chemistry; Datasets S1–S3 are described there as eccDNA region, gene-copy and repeat analyses (still not downloaded; not chemistry by their legends). The scraper finds only the ACT1/qPCR and inverse-PCR validation primers (PDF lines 774, 906–909); none in the SI.
Molecular order
🟢 Yeast cells (1010) are disrupted with glass beads in Plasmid Mini AX L1 solution; the kit's alkaline treatment, protein precipitation and ion-exchange column separate circular from chromosomal DNA. Before the column, plasmid spike-ins are added to the lysate at 1:1 (pBR322), 1:50 (pUC19) and 1:2,500 (pUG72) per cell, assuming 8 × 109 genomes; they serve as internal detection-limit standards (Fig. S5) and are now an input of the purification step. The eluate (6–16 µg) is precipitated into TE. NotI (1 FastDigest unit, 37 °C, 17 h; 80 °C 5 min) cuts chromosomal DNA to expose more ends, then Plasmid-Safe ATP-dependent DNase (37 °C, ATP and 16 U enzyme added every 24 h) runs for 130 hours and is heat-inactivated (70 °C, 30 min). One percent (5 µL) of the enriched fraction is amplified with phi29 polymerase by the REPLI-g Mini protocol (30 °C, 16 h). The product is sonicated to about 300 nt (Covaris LE220); 300 ng is loaded on an Apollo 324 robot, which adds adapters and 6-base barcode index labels, and libraries are sequenced single-end on HiSeq 2000. 🟡 Model correction (2026-10-17): the circle is no longer built by the shared ssDNA circularisation helper, which implied a ligation that never happens; it is declared as a pre-existing closed circle, one strand drawn. The former representative phi29 sequence/site has since been removed; REPLI-g priming sites and sequence geometry remain unassigned in the current model. 🟡 The page shows the Apollo step as a warned boundary: the paper does not state the joining chemistry or whether any library PCR follows. The earlier model's explicit adapter ligation and library-PCR steps were model insertions and were removed.
🟢 Read length: Results give 141-nt single-end reads; Mapping of Reads says the longest reads (215 nt; samples S2, Z4, R1) were adapter-trimmed with Cutadapt before the 141-nt reads were mapped. Reads were demultiplexed by index barcode (0 mismatches in the first lane, 1 in later lanes); how the index was read is not stated.
Published discrepancy (shown on the page): Methods "Sequencing" says samples were "sequenced up to 100 Mb", whereas Results report 40–100 million reads per population; 100 Mb of 141-nt reads would be about 0.7 million reads. The model sets no depth.
Boundary and uncertainty
The circles are biological inputs, not library-prep intermediates. The source names Apollo324 and six-base barcode oligos; actual adapter/index identities, geometry and molecular placement remain unassigned in this model. The public page now uses an explicit library boundary instead of a conventional single-index Illumina shell. This is separate from CRISPR CIRCLE-seq.
🟢 The Methods also print ACT1 PCR/qPCR and inverse-PCR pairs for several confirmed circles and spiked plasmids. Those oligos test exonuclease removal or validate individual circles; none enters the sequenced library. No Apollo ordering table or adapter lot is identified, so raw reads could at most support inferred adapter sequence and index content, not chemical modification or reagent identity.
Source-owned validation migration (2026-10-18)
This capped pass read two originals: the defining PMC4475933 article Results and Methods (Circle-Seq purification/digestion/amplification, Sequencing and Mapping of Reads), plus the published SI original identity and FigS1/FigS5 captions (linear-DNA hydrolysis assay and independent plasmid spike-ins). Mandatory bundle primer-scraper pointers were checked in these originals. Detailed predecessor plasmid methods, REPLI-g primer chemistry and Apollo324 kit documents remain deferred.
batch_ngs.truseq_library and its assumed dA junction/standard arm placement are removed. Apollo324 supplies source-named adapter reagents and six-base barcode oligos, represented as a reagent inventory with unknown molecular placement. The final molecule’s adapter/index arrangement and library PCR status remain unassigned, rather than choosing a canonical TruSeq endpoint.
The arbitrary16-base native-circle sequence and8-base phi29 primer were removed. Native eccDNA and independent plasmid standards retain source-qualified circular roles; REPLI-g priming sequences, repeat count and branching geometry remain unassigned. Different cellular DNA populations occupy separate Scene rows. Plasmid-Safe hydrolysis produces an explicitly unresolved molecular product class, not physically discarded waste. Source-described1%(5µl) sampling is explicit, with remaining99% disposition unassigned. Subsequent sonication produces fragment roles rather than retaining an unfragmented RCA drawing.
The source141base single-end reads and215base S2/Z4/R1 reads remain distinct sample scopes. Six-base barcode oligos do not prove a six-cycle index acquisition. The published100Mb versus40–100million-read depth discrepancy remains visible on the page; it does not select a molecular endpoint. This is not a full source audit or an accepted publication-absence claim.