GAM — research notes
Beagrie et al., Nature (2017), doi:10.1038/nature21411.
Sources read
- 🟢 Defining article, Methods and Supplementary Guide (PMCID: PMC5366070).
- 🟢 Primary sequencing deposit GSE64881.
- 🟢 The later Multiplex-GAM paper (doi:10.1038/s41592-023-01903-1) was read only to separate the original one-profile-per-library protocol from the later multi-profile variant.
What constitutes one GAM observation
GAM does not ligate spatial neighbours. A random approximately 220-nm plane through one fixed nucleus selects many physically separate pieces of chromosomes. One column of the eventual segregation matrix is the set of genomic windows detected in that nuclear profile (NP); contacts are inferred because nearby loci co-segregate across many independent NPs.
- 🟢 Mouse ESC nuclear architecture is strongly fixed, embedded in 2.1 M sucrose, frozen and cut into approximately 220-nm ultrathin cryosections.
- 🟢 Sections are placed on PEN membrane slides. One visually identified NP is cut and laser-catapulted into an adhesive PCR cap. One cap in each eight-cap strip is empty and follows the entire WGA procedure as a contamination control.
- 🟢 DNA is extracted and whole-genome amplified with the Sigma WGA4 single-cell kit. The defining methods disclose the temperatures, times and reagent roles but not the proprietary adapter bases.
- 🟢 WGA material is purified. A TruSeq DNA HT library uses up to 1.1 µg and is Pippin selected to 300–500 nt; the alternative TruSeq Nano DNA HT workflow uses up to 200 ng and a bead selection centred near 350 nt.
- 🟢 Ninety-six indexed NP libraries are pooled. The original mESC data comprise 408 passing NPs after excluding samples with less than 15% uniquely mapped mouse reads.
Final molecule and read entry
- 🟢 WGA leaves a 30-base amplification adapter on both ends of each genomic piece.
- 🟢 The final sequencing shell is the named TruSeq DNA HT/Nano chemistry. Its sample indexes identify an NP library, not a molecular contact or cell barcode.
- 🟢 Pools of 96 were sequenced "in single end 100 bp rapid-run mode on two lanes of an Illumina HiSeq"; because each library has 30 bp WGA adaptors at both ends, "the flow cell was not imaged for the first 30bp of each run" (dark cycles; custom recipe with Illumina). There is no Read 2 observation in this defining run.
- 🟡 Whether the 30 dark cycles are part of the 100 or precede 100 imaged cycles is not stated. An earlier version of this note and the model asserted 30 + 100 = 130 cycles; the model now uses the printed 100-cycle Read 1 and leaves the imaged genomic length open.
- 🔴 WGA4 adapter base sequences are proprietary. The schematic preserves their published 30-nt length and marks the bases inferred/unknown rather than inventing an oligo.
Protocol/version boundary
The later Multiplex-GAM protocol can put several NPs into one library and uses Nextera; later GAM applications also introduced a public GAT-7N/GAM-COM DeepVent WGA. Those are useful developments, but neither is silently substituted for the original 2017 GAM page.
Bounded source pass 2026-10-17 (round breadth-first-10)
The source directory was missing; tools/get_sources.py --slugs gam__10.1038+nature21411 fetched the PMC Cloud author-manuscript JATS/PDF, NIHMS supplements and Springer ESM. Read: PMC5366070 JATS Methods lines 171–201 (cell culture, cryosections, NP isolation, WGA, library preparation, sequencing, mapping); Supplementary Guide (whole, 31 lines); Supplementary Table 1 header and kit/index columns. GEO GSE64881 returned a reCAPTCHA page this pass (manual row) and was not re-read.
- 🟢 Fixation 4% then 8% EM-grade PFA in 250 mM HEPES (10 min, 2 h), 2.1 M sucrose, ~220 nm Tokuyasu cryosections on PEN membrane slides, sucrose washed off (PBS, water).
- 🟢 WGA4 with "minor modifications to the previously described protocol" (ref. 38): proteinase K in single cell lysis and fragmentation buffer, 50 °C 4 h; 99 °C 4 min; library preparation buffer and stabilisation solution, 95 °C 4 min; library preparation enzyme 16/24/37 °C 20 min each, 75 °C 5 min; then amplification master mix and WGA DNA polymerase with the supplier's program. The model now separates lysis from the proprietary library-preparation step (a warned magic boundary).
- 🟢 Supplementary Table 1: 85 NP libraries TruSeq HT and 386 TruSeq Nano, plus 5 Nano negative controls, all with 8-nt i7 and i5 indexes; the positive control was TruSeq DNA LT with a 6-nt index. Acquired index cycles are not stated.
- Published discrepancy (positive control): the NP-isolation paragraph names WGA-amplified E14 mESC genomic DNA, while the WGA paragraph adds 1 µl human genomic DNA to an empty lid. Shown on the page; not resolved.
- Open: TruSeq DNA HT/Nano normally fragment input; the Methods still state that each library carries 30 bp WGA adaptors at both ends. The model follows that statement.
- Deferred: WGA4 kit technical bulletin; ref. 38 predecessor protocol (Baslan et al., Nat Protoc 2012, doi:10.1038/nprot.2012.039); GEO GSE64881.
Batch02 native-graph migration (2026-10-18)
The native local graph now selects the original TruSeq DNA HT route. Its Pippin300–500nt selection is distinct from the alternative Nano350nt bead-selection branch. WGA PCR receives actual WGA4-prepared independent profile regions; it no longer receives a completed sequencing library. WGA MinElute recovery is explicit, followed by an unresolved manufacturer library-preparation boundary and the known HT Pippin selection. Native HT end processing/PCR/adapter geometry is not filled by a generic TruSeq shell.
The source30bp WGA4 adapter extents remain, but their bases and physical primer species are unassigned. Genomic molecular extent is no longer set to a30kb analysis-bin size. Profile regions remain separate molecular rows; no contact junction is created. The source Table1 provides8base HT NP index metadata, represented as an inventory with unknown native placement, not as an acquired8cycle index run. The source100bp single-end statement and first30 dark cycles retain their unresolved relationship, rather than assuming70 or100 imaged genomic bases. Other section/profile material has unresolved later disposition instead of an unsupported physical discard. The published positive-control species discrepancy remains visible.
This capped pass read two originals: published PMC5366070 JATS Methods183–197 (WGA4, MinElute, HT/Nano alternatives, pooling and dark cycles) and published SupplementaryTable1 NP/library/index columns. Mandatory bundle scraper ran; the large derived Table2 was not scanned or used. WGA native oligos/attachment chemistry, exact HT end processing/PCR and dark-cycle recipe remain deferred. Earlier evidence supports the retained nuclear-profile sampling/control labels; it was not comprehensively re-read. No publication-absence claim is accepted.