Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. The scoped inferred predecessor is the most plausible earlier declared design given the inspected mechanism and chronology; no formal descent is asserted.
Tn5 loaded only with MEDS-A creates one universal transposon-primer end. A locus-specific biotinylated linear extension and streptavidin capture enrich one accessible locus before nested amplification and MiSeq sequencing.
MEDS-A/MEDS-REV, the Tn5A primer and the rs12269414 example primers are source-exact. Locus primers are experiment-specific. The nested forward oligo's printed 5′ tail is the Illumina paired-end/Genome-Analyzer adaptor arm, not the current TruSeq Read 2 arm. Only the outer flow-cell and index shell is inferred: the paper refers to a published MiSeq barcoding PCR without printing its primers or which amplicon end receives P5.
Key oligos
MEDS-A top — 5′-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-3′
MEDS-REV bottom — 5′-pCTGTCTCTTATACACATCT/intT-3′
Tn5A PCR primer — 5′-TCGTCGGCAGCGTCAG-3′
rs12269414 biotinylated linear-PCR primer — 5′-/5Biosg/CCAGGAGTTGGAACCTGC-3′
Amplify with the nested locus and common Tn5A primers. Inputs: nested rs12269414 forward oligo; common Tn5A PCR primer; gap-fill, extension and PCR polymerase
Add MiSeq barcodes in a second PCR. Inputs: MiSeq i5 barcoding primer; MiSeq i7 barcoding primer; gap-fill, extension and PCR polymerase
Other material outcomes
non-library tagmentation products — discard
fragments without usable MEDS-A insertions do not reach targeted enrichment
Molecular structure is not represented in this graph.
Molecular structure is not represented in this graph.
Final sequencing library
Representative rs12269414 amplicon. One boundary is fixed by the nested locus primer and its source-exact Illumina PE adaptor tail, the other by a nearby MEDS-A insertion. The flow-cell/index shell is inferred: the second PCR adds the barcodes of ref 31 (Kozarewa & Turner 2011); the defining paper prints neither those primers nor which amplicon end receives P5.
Sequencing primers
The reported 2 × 150-base MiSeq reads approach the locus-defined amplicon from both ends and were merged when their inserts overlapped.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
Sequencing primers on the final library
Read
Primer
Sequence
Lands on
First bases read
Read 1
nested-forward adaptor tail primer (Illumina PE arm) Cooper et al. 2023 Supplementary Tables S1-S2 nested forward oligos
5'-TCGGCATTCCTGCTGAACCGCTCTTCCGATCT-3' Printed as the 5′ tail of every nested forward oligo; the matching sequencing primer itself is delegated to ref 31.
anneals to the bottom strand over nested-forward adaptor tail (Illumina PE arm)
CCTCTTGCCTTG… (from nested rs12269414 locus primer)
Read 2
MEDS-A handle primer (Tn5A side) Cooper et al. 2023 Methods 'Tn5 production' (MEDS-A) and 'ATAC assay, linear PCR and nested PCR' (Tn5A primer)
5'-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-3' The tagmentation-installed MEDS-A handle is the only adaptor at this end; the paper does not print the primer loaded for this read.
anneals to the top strand over MEDS mosaic end reverse complement, MEDS-A primer-entry complement
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
150
nested rs12269414 locus primer (cycles 1–18); targeted accessible-DNA amplicon (from cycle 19; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Index 1 (i7)
—
not acquired
No — not sequenced
Index 2 (i5)
—
not acquired
No — not sequenced
Read 2
150
targeted accessible-DNA amplicon (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Sequencing limitation. The terminal MiSeq index shell is inferred: the second PCR adds the barcodes of ref 31 (Kozarewa & Turner 2011); the defining paper prints neither those primers nor which amplicon end receives P5. Index cycles are therefore not represented as acquired reads.