GRO-cap

Defining paper: Core et al., Nature Genetics (2014), doi:10.1038/ng.3142. The article, methods and supplements were read from PMCID PMC4254663.

Molecular boundary

🟒 GRO-cap begins with BrUTP-labelled global nuclear run-on RNA. It then enriches capped nascent 5β€² ends: uncapped 5β€² phosphates are removed, tobacco acid pyrophosphatase exposes a ligatable monophosphate only at capped ends, and a no-TAP library controls background.

🟒 The paper delegates GRO-cap library preparation to Kruesi et al. (2013). The informative coordinate is the first transcribed nucleotide, not the run-on-labelled 3β€² end. Its separate PRO-seq method names TruSeq Small RNA adapters; that statement does not establish the adapter used for GRO-cap.

🟒 Kruesi et al., eLife 2013, doi:10.7554/eLife.00808, original PDF Methods pp. 22–23 (local extracted lines 1163–1203), explicitly identifies the GRO-cap adapters as TruSeq RNA RA3 (Illumina part 15013207) and RA5 (part 15013205). After the first BrU affinity capture, RA3 is ligated to the RNA 3β€² end; a second BrU capture follows. Terminator 5β€² phosphate-dependent exonuclease degrades uncapped 5β€² monophosphate RNA, and Antarctic phosphatase blocks remaining uncapped 5β€² ends. Only then is the material split for TAP+ and no-TAP control; RA5 is ligated to the newly decapped 5β€² end in the TAP+ branch, followed by a third BrU capture. The earlier graph reversed RA3/RA5 order and omitted the Terminator step; that was a repository model error.

🟒 The official Illumina TruSeq Small RNA sequences identify RA3 as 5β€²-TGGAATTCTCGGGTGCCAAGG-3β€² (the vendor prints T) and RA5 as 5β€²-GUUCAGAGUUCUACAGUCCGACGAUC-3β€² (vendor RNA spelling). The same page prints RTP, RP1 and an RPI six-base-index family. These are kit reference sequences, not a record of the particular 2013 kit revision or chosen index.

🟒 The Illumina TruSeq Small RNA guide, part 15004197 Rev C (2011), an original vendor guide mirrored by Boston University, lists RA3 part 15013207 and RA5 part 15013205 (local extracted lines 451–455). These match Kruesi's named part numbers. Its Table 7 (local lines 1643–1760) lists RPI1–48 index six-mers; it does not give the full RA3/RA5 strands or the index assignments for Core et al. 2014.

🟑 The kit reference lists RTP 5β€²-GCCTTGGCACCCGAGAATTCCA-3β€², RP1 5β€²-AATGATACGGCGACCACCGAGATCTACACGTTCAGAGTTCTACAGTCCGA-3β€² and RPI-family 5β€²-CAAGCAGAAGACGGCATACGAGAT[6-base index]GTGACTGGAGTTCCTTGGCACCCGAGAATTCCA-3β€². Kruesi prints RP1 and the RPI-family structure in its adjacent GRO-seq method (original PDF Methods p. 22, local text lines 1157–1161); Core 2008's inherited RT/PCR method names Illumina kit primers without printing individual bases. These kit sequences are candidates for the inherited GRO-cap completion, but the precise 2014 primer/index pair is unverified.

Evidence boundary

🟑 The 2011 vendor guide verifies the historical component identities, and the current vendor page supplies their sequences, but complete historical ordered-strand details and Core2014 GRO-cap primer/index identity and length remain unassigned. The six-base RPI family belongs to adjacent GRO-seq and is not an established GRO-cap assignment. Kruesi delegates GRO-cap reverse transcription and final amplification to Core et al. 2008. Its original Science Supporting Online Material (doi:10.1126/science.1162228, pp. 18–19, local extracted lines 699–710) uses the Illumina Small RNA RT primer with SuperScript III at 44Β°C then 52Β°C, RNase digestion, 15 Phusion PCR cycles with Illumina kit primers, and PAGE purification. That source does not identify a particular index member for the later GRO-cap libraries. The diagram marks kit-reference adapter bases as inferred for the historical experiment and leaves the selected index and final primer geometry unresolved.

Oligo source audit

🟒 Checked the open author manuscript (ng.3142_PMC4254663.pdf.txt, lines 625–634) and publisher supplementary PDF (ng.3142_41588_2014_BFng3142_MOESM77_ESM.pdf.txt). The Methods assign TruSeq Small RNA adapters to PRO-seq, after separately assigning GRO-cap to Kruesi et al. (2013). The supplement contains figures and analyses, not a GRO-cap adapter/primer table. Kruesi's original Methods resolve the adapter names, ligation order and cap-selection chemistry. The cited Core et al. 2008 main article (doi:10.1126/science.1162228) is locally available; its original Science Supporting Online Material was independently read from a full PDF mirror because the PMC supplementary endpoint is gated. The former note incorrectly assigned the PRO-seq kit to GRO-cap; this was a repository reading error, not a published discrepancy.

Independent decoupling check

🟒 Rereading the original Core2014 Methods (local JATS534–549), Kruesi2013 Methods pp21–23 (local text1080–1211) and Core2008 original Science SOM pp18–19 (local text683–710) confirms the local TAP+ order. The adapter ligations are RA3 then RA5, with three BrU affinity captures and Terminator/phosphatase selection before TAP. The inherited completion is RT, RNase digestion, PCR and PAGE. The adjacent GRO-seq poly(A)/circularization and RP1/RPI declaration and Core2014's separate PRO-seq adapter statement do not assign GRO-cap primer strands, index length or physical library geometry.

🟒 Positive historical base evidence: Kruesi's joint β€œMapping of GRO-seq and GRO-cap reads” section (local text1205–1211) explicitly prints the cutadapt target TGGAATTCTCGGGTGCCAAGG. This matches the current RA3 reference. It supplies a historical adapter read-through target without establishing all ordered-strand terminal modifications or the later sample-specific PCR/index assignment. The model's conditional historical adapter representation should be read with that positive evidence, rather than as a claim that no historical adapter bases were printed.

The index question concerns an unassigned GRO-cap primer/index identity and length; it must not presuppose the neighboring GRO-seq six-base RPI family. These are model assignments to investigate, not confirmed source omissions.

Linked study metadata

🟒 The original GEO records GSE60456 and GSE43087 contain sample-level GRO-cap preparation descriptions, rather than just links to the papers. The four Core2014 samples and eight Kruesi2013 samples corroborate the RA3-first, cap-selection, RA5-second order. The precursor metadata also prints the same RA3 trimming target as the original paper.

🟒 Original experiment records SRX682016–SRX682019 and SRX212227–SRX212234 explicitly declare a single-read library layout on Illumina HiSeq2000. This is a deposited read-layout statement; it does not select a physical PCR/index primer or establish its binding geometry. The original publisher supplement's Table1 (p29) labels its 30bp values as length of mapped reads. GEO likewise labels 30bp as processing trim, so neither value is an acquired sequencing-cycle recipe.

The paper identifies the Cornell browser-hub link as genomic tracks and TSS results; its original URL now returns an error. The source review records that unavailable original separately from the primer/index model questions. No source-absence conclusion is inferred from that error.

The article separately cites Kwak for PRO-seq and Wang for GRO-seq. Kruesi's Ingolia poly(A)/circularization reference belongs to its adjacent GRO-seq method; its GRO-cap completion explicitly points to Core2008. Those neighboring recipes are not assigned to this declaration.

Bounded pass 2026-10-17

🟒 Re-read Core2014 Methods (local JATS534–549) and Kruesi2013 original Methods pp21–23 (local text1080–1203). Kruesi's NRO reaction uses 500 Β΅M ATP, GTP and Br-UTP, 2 Β΅M CTP plus Ξ±-32P-CTP and 1% sarkosyl for 5 min at 30 Β°C; enrichment uses anti-deoxyBrU agarose beads (Santa Cruz sc-32323-ac). GRO-cap uses those NRO and bead steps except that its RNA is not base hydrolysed, and it does not repeat the GRO-seq 3β€² end repair, poly(A) or circularization steps. The model labels now carry the run-on composition and bead identity; the graph order (RA3 β†’ second capture β†’ Terminator β†’ Antarctic phosphatase β†’ split/TAP β†’ RA5 β†’ third capture β†’ Core2008 RT/PCR/PAGE) was confirmed unchanged. The no-TAP control branch remains undrawn, and the historical primer/index assignment remains an open model question.