GUIDE-seq — research notes

Assay scope

The library captures genomic DNA beside dsODN insertions at nuclease-induced breaks. The local declaration covers the tag, half-functional adapter, nested library primers and sequencing readout; genomic targets remain schematic.

Sources read

2026-10-17 bounded re-reading (round 2026-10-17-breadth-first-11): Online Methods "Isolation and preparation of genomic DNA for GUIDE-Seq" (JATS lines 129–131) and the corrected MOESM21 Supplementary Methods protocol steps 1–12 (extracted lines 33074–33262), including the equipment list (line 33026). The four AMPure XP SPRI cleanups, the DNAdvance genomic-DNA isolation, the on-bead PCR 2 input and the qPCR normalization to 1.2 × 10¹⁰ molecules are now represented in protocol_graph() with their removed fractions.

Nothing in this note or in tools/guide_seq.py is taken from a secondary schematic.

Oligos, verbatim with their modifications

🟢 Supplementary Table 4 and the Online Methods, exactly as printed (* = phosphorothioate linkage, [Phos]/P = 5′ phosphate):

NameSequence 5′→3′
dsODN strand A5'-P-G*T*TTAATTGAGTTGTCATATGTTAATAACGGT*A*T-3'
dsODN strand B5'-P-A*T*ACCGTTATTAACATATGACAACTCAATTAA*A*C-3'
Y-adapter A01 (long strand)AATGATACGGCGACCACCGAGATCTACACTAGATCGCNNWNNWNNACACTCTTTCCCTACACGACGCTCTTCCGATC*T
MiSeq common adapter[Phos]GATCGGAAGAGC*C*A
P5_1AATGATACGGCGACCACCGAGATCTA
P5_2AATGATACGGCGACCACCGAGATCTACAC
Nuclease_off_+_GSP1GGATCTCGACGCTCTCCCTATACCGTTATTAACATATGACA
Nuclease_off_+_GSP2CCTCTCTATGGGCAGTCGGTGATACATATGACAACTCAATTAAAC
Nuclease_off_-_GSP1GGATCTCGACGCTCTCCCTGTTTAATTGAGTTGTCATATGTTAATAAC
Nuclease_off_-_GSP2CCTCTCTATGGGCAGTCGGTGATTTGAGTTGTCATATGTTAATAACGGTA
P701CAAGCAGAAGACGGCATACGAGATTCGCCTTAGTGACTGGAGTCCTCTCTATGGGCAGTCGGTGA
custom Index 1 primerATCACCGACTGCCCATAGAGAGGACTCCAGTCAC
custom Read 2 primerGTGACTGGAGTCCTCTCTATGGGCAGTCGGTGAT

A02–A16 differ from A01 only in the 8-nt sample barcode; P702–P708 differ from P701 only in the 8-nt P7 barcode. Every oligo above is reproduced in tools/guide_seq.py, and tools/selftest_source_oligos.py re-checks the model's copies against the extracted source text.

How they interlock (computed in tools/guide_seq.py, not eyeballed)

🟢 Every identity below is asserted by _require(...) at module import, so the page cannot be built if one stops holding.

Molecular order

🟢 Supplementary Methods, "Protocol for GUIDE-seq Library Preparation", in order:

  1. Y-adapter preparation. A01–A16 are annealed to the MiSeq common adapter (95 °C → 60 °C → slow ramp to 4 °C). The molecular index enters the workflow here, as part of a synthetic oligo — not during PCR.
  2. dsODN capture. The blunt, 5′-phosphorylated 34-bp dsODN with phosphorothioate linkages at both the 5′ and 3′ ends of both strands is nucleofected with the RGN components and captured at on- and off-target breaks by NHEJ.
  3. Genomic DNA isolation. 🟢 Online Methods: solid-phase reversible immobilization magnetic beads (Agencourt DNAdvance). The graph now carries this bead isolation as an explicit extraction with its unbound fraction, ahead of shearing.
  4. Shearing and cleanup. 400 ng genomic DNA in 120 µl, sheared to an average length of 500 bp, then a 1X AMPure XP SPRI cleanup eluted in 15 µl. 🟡 Published source conflict: the Online Methods name a "Covaris S200"; the Supplementary Methods protocol and equipment list name the Covaris S2 (S-2 Focused Ultra-sonicator). The model declares only the ~500 bp target, not an instrument model.
  5. End repair and A-tailing — one tube: end-repair mix plus non-hot-start Taq, with 12 °C / 37 °C / 72 °C steps. The 72 °C step is the dA addition.
  6. Adapter ligation. Annealed Y adapter plus T4 DNA ligase, 16 °C then 22 °C. The adapter's 3′ dT pairs with the fragment's 3′ dA, so both ends of every fragment receive the adapter — but only one tail exists, so nothing is amplifiable without the tag. A 0.9X SPRI cleanup (eluted in 12 µl) follows, removing unligated adapter.
  7. PCR 1 — GSP1 + P5_1, touchdown programme. For discovery, separate master mixes and separate reactions for the + (sense) and − (antisense) GSP sets. Deep-sequencing validation instead uses one master mix with a normalized primer pool and the non-touchdown validation programme; that branch is not drawn. A 1.2X SPRI cleanup (eluted in 15 µl) follows; 🟢 the PCR 2 recipe takes "DNA sample with beads (from Step 8)", so the cleanup beads are carried into the nested reaction.
  8. PCR 2 — nested GSP2 + P5_2 + P7_#, same programme. GSP2 installs the P7 arm; P7_# completes it and adds the 8-nt P7 barcode. At least four different P7_# are used per run for image registration. A 0.7X SPRI cleanup (eluted in 30 µl) follows.
  9. Sequencing. qPCR quantification, normalization to 1.2 × 10¹⁰ molecules, MiSeq Reagent Kit v2 300-cycle, 3 µl of 100 µM custom Index 1 primer into cartridge position 13 and 3 µl of 100 µM custom Read 2 primer into position 14, cycles 151 | 8 | 16 | 151 "with the paired-end Nextera sequencing protocol".

Final library and read layout

🟢 The library is a hybrid: a TruSeq P5/Read 1 side installed by ligation, and an AMP-style arm on the P7 side installed by PCR.

5'- AATGATACGGCGACCACCGAGATCTACACSSSSSSSSNNWNNWNNACACTCTTTCCCTACACGACGCTCTTCCGATCTXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXGTTTAATTGAGTTGTCATATGTATCACCGACTGCCCATAGAGAGGACTCCAGTCACIIIIIIIIATCTCGTATGCCGTCTTCTGCTTG -3'
    P5                           8-nt sample barcode                             adapter 3' dT : fragment dA              integrated dsODN end  Read 2 / Index 1 arm              P7 barcode reverse complement
                                         8-nt molecular index                     adjacent genomic DNA                                                                                    P7 reverse complement
                                                 Read 1 arm

NNWNNWNN is a constrained degenerate molecular index

🟢 Supplementary Methods: "The adapters also contain 8-mer NNWNNWNN (N = A, C, T, or G; W = A or T) molecular indexes." Positions 3 and 6 are restricted to A/T, so the index has 4⁶ × 2² = 16 384 forms, not 4⁸ = 65 536. The molecular feature records encoding="degenerate" to preserve those restrictions. The paper’s broader term "random" does not imply that all eight positions are unrestricted N bases.

Recorded source conflict: where the molecular index is installed

Two statements in the same paper disagree:

The protocol and the oligo table win: the index is a synthesized part of the ligated adapter, with the explicitly restricted NNWNNWNN alphabet. An earlier version of this note and of the model repeated the main text's looser phrasing ("nested amplification installs an 8-bp random molecular barcode") and placed the index inside the insert, i.e. inside Read 1. That was wrong on both counts.

Boundary

GUIDE-seq measures breaks that capture the dsODN in living cells. It is distinct from CIRCLE-seq, where purified genomic circles are cut by Cas9 in vitro.

Recovered PMC supplement: an older source version

The actual PMC Cloud object NIHMS647337-supplement-1.pdf is 214,485,908 bytes. It was publicly accessible; the former unavailable status arose from the generic 120 MB downloader cap. It was fetched through the standard source Folder.save API with an explicit 215 MB cap for this identified document and validated as a complete PDF. It is retained separately from corrected publisher MOESM21.

Direct text and visual comparison of PMC p. 32 and corrected publisher p. 33 shows the GSP1 label swap described by the publisher's correction notice. The older PMC table labels the GTTTA… GSP1 body + and ATACC… −; corrected MOESM21 labels ATACC… + and GTTTA… −. The two GSP2 rows are unchanged. The corrected publisher file also distinguishes discovery and validation cycling, whereas the older PMC protocol prints only the validation program. The model uses corrected labels and does not substitute the older protocol. This version difference is also disclosed on the public schematic.

Both copies print the same 151/8/16/151 sequencing layout and custom Index 1/Read 2 cartridge positions 13/14. The physical Index 2 mechanism comes from the separately versioned manufacturer documentation above.

Model questions and linked-source scope

The audit accepts no missing-information claim from these model boundaries.