m6A-seq / MeRIP-seq — antibody enrichment of methylated RNA
Protocol relationships
Some predecessor or candidate links are withheld until the corresponding protocol pages are available.
No formal ancestor assigned in this review. The earlier method is a loose chemistry analogue only, not evidence of inspiration or descent; guessed candidates remain separately labelled.
Poly(A)-selected RNA is chemically fragmented to about 100 nt, immunoprecipitated with an anti-m6A antibody, competitively eluted with free N6-methyladenosine, and converted with an Illumina mRNA sequencing kit into a library alongside the matched input fragments.
The Methods name only an “mRNA sequencing kit (Illumina)”, with no catalogue number, adapter, reverse-transcription or PCR oligos. Library construction is therefore a warned kit boundary and the final library ends are role tokens, not a reconstructed adapter shell or sample-index design.
Reaction workflow
ip m6A-seq library
Select polyadenylated RNA. Inputs: GenElute mRNA miniprep kit, one round (Sigma-Aldrich). Other outputs: non-polyadenylated RNA → discard
Chemically fragment poly(A)-selected RNA. Inputs: 10 mM ZnCl2, 10 mM Tris-HCl pH 7, 94 °C 5 min; EDTA stop and ethanol precipitation
Reserve matched input and IP aliquots. Other outputs: matched input-control RNA fragments
Immunoprecipitate m6A-containing fragments and wash extensively. Inputs: affinity-purified anti-m6A polyclonal antibody (Synaptic Systems) in IPP buffer, 2 h 4 °C; protein-A beads (Repligen) 2 h 4 °C. Other outputs: unbound RNA and washes → discard
Competitively elute enriched RNA with free m6A. Inputs: free N6-methyladenosine (Sigma-Aldrich) in IPP buffer; ethanol precipitation
Generate the ip library with the Illumina mRNA sequencing kit. Inputs: ip mRNA sequencing kit reagents (Illumina; catalogue number not given)
input m6A-seq library
Select polyadenylated RNA. Inputs: GenElute mRNA miniprep kit, one round (Sigma-Aldrich). Other outputs: non-polyadenylated RNA → discard
Chemically fragment poly(A)-selected RNA. Inputs: 10 mM ZnCl2, 10 mM Tris-HCl pH 7, 94 °C 5 min; EDTA stop and ethanol precipitation
Reserve matched input and IP aliquots. Other outputs: RNA aliquot for immunoprecipitation
Generate the input library with the Illumina mRNA sequencing kit. Inputs: input mRNA sequencing kit reagents (Illumina; catalogue number not given)
Other material outcomes
non-polyadenylated RNA — discard
is removed by poly(A) selection
Molecular structure is not represented in this graph.
unbound RNA and washes — discard
is not retained by the antibody–protein-A beads
Molecular structure is not represented in this graph.
Final sequencing library
The IP and matched input use the same unreconstructed kit chemistry; enrichment is biological selection, not a retained molecular barcode.
Sequencing entry
Illumina Genome Analyzer GAIIx, 10 pM template per sample for cluster generation, genomic sequencing kit V2 (Methods “m6A-seq”). The coverage analysis treats each read as a sequenced 36-nucleotide stretch extended in silico to 100 nt in the 5′→3′ direction (Methods “Calculation of coverage”).
Sequencing-primer binding on the final library
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
36
Methods: 36-nucleotide sequenced stretch of the IP or input RNA-fragment cDNA; a second read is not described and strand/orientation relative to the RNA is not stated.