Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
Fragment genomic DNA, repair and dA-tail it, ligate fully methylated adapters, then denature and bisulfite-convert before limited uracil-tolerant PCR.
The paper specifies NEXTflex Bisulfite-Seq Barcodes–12 (Bioo Scientific, cat. 511912), not an unspecified adapter. It is a single-index, 6-nt i7, TruSeq-compatible library: standard Read 1, Index 1 and Read 2 sequencing primers bind; there is no i5 index.
Reaction workflow
MethylC-seq sequencing library
Mechanically fragment genomic DNA. Inputs: mechanical shearing condition
Add one 3-prime dA to each end. Inputs: dA-tailing enzyme mix
Present adapter and substrate ends. The protocol identifies NEXTflex Bisulfite-Seq Barcodes–12 and dA-tailed inserts, but does not print the ligation adapter duplex or its overhang.
Ligate protected NEXTflex adapters before conversion. Inputs: protected NEXTflex Bisulfite-Seq adapters; DNA ligase
Denature and bisulfite-convert the ligated DNA. Inputs: bisulfite conversion reagent
PCR-restored NEXTflex library: a single 6-nt i7 and the standard TruSeq-compatible sequencing-primer sites. Unmethylated genomic C is read as T; protected adapter 5mC remains C through bisulfite treatment.
Sequencing primers
Standard TruSeq Read 1, Index 1 and Read 2 primers bind to the NEXTflex library. There is no Index 2 read. Paired reads traverse the converted insert, whose C/T outcome is compared with the unconverted reference sequence.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
anneals to the top strand over dA junction / Read 2 site start, Index 1 / Read 2 arm
xxxxxxxxxxxx… (from C→T-converted genomic insert)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
not fixed
C→T-converted genomic insert (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Index 1 (i7)
not fixed
sample index (cycles 1–6)
No — use for sample demultiplexing
Index 2 (i5)
—
not acquired
No — not sequenced
Read 2
not fixed
C→T-converted genomic insert (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end