Microbe-seq — research notes

Defining source: Zheng et al., 2022, High-throughput, single-microbe genomics with strain resolution, applied to a human gut microbiome, Science, doi:10.1126/science.abm1483.

Sources read

Molecular path (preprint)

🟡 Microbes are encapsulated with lysis reagents. Sample droplets are then merged with MDA-reagent droplets and incubated at 30 °C for 6–8 h, then 65 °C for 10 min. A second merger adds commercial Nextera tagmentation reagent (55 °C, 10 min). A third merger adds PCR reagents and one barcoding hydrogel bead. The barcoding program starts at 72 °C for 4 min, which covers gap filling of the tagmented ends. It continues at 98 °C for 30 s, then 10 cycles of 98 °C 7 s / 60 °C 30 s / 72 °C 40 s.

🟡 Droplets that merged during PCR are removed with a droplet size-filter device. The emulsion is broken with 20% PFO, and the aqueous phase is purified with 1.1× AMPure. A bulk Phusion PCR (5–10 cycles) uses P5PE1 (IDT) and a Nextera i7 primer (Illumina) to add the sequencing adapters and one sample index. A 0.8× AMPure cleanup follows.

🟡 Beads are made by polymerising droplets that contain an acrydite-modified, photocleavable-linker hydrogel oligo. Two split-and-pool Bst 2.0 extension rounds follow, in 96 and then 384 wells, giving 96 × 384 = 36,864 combinations.

Table S6 oligos (preprint, verbatim)

Role5′→3′ oligo, spaces as printed between constant arms and barcode
Barcode-1 oligo-1AAGGCGTCACAAGCAATCACTC AAACAAAC AGATCGGAAGAGCGTCGTGTAGGGAAAGAG
Barcode-2 oligo-1TCTCTTATACACATCTGACGCTGCCGACGA AAACAAAC AAGGCGTCACAAGCAATCACTC

🟢 (in the preprint) Barcode 1 has 24 oligos each of length 8, 9, 10 and 11 nt; barcode 2 has 384 oligos of 8 nt. The self-test re-derives these counts from the table text.

🟡 Derived interlock (computed in microbe_seq.py): the barcode-1 3′ arm anneals to the hydrogel oligo, so the bead strand carries CTCTTTCCCTACACGACGCTCTTCCGATCT. The barcode-1 5′ arm is the 22-nt linker that barcode 2 anneals to. The barcode-2 5′ arm copies into TCGTCGGCAGCGTCAGATGTGTATAAGAGA, which is the Nextera S5 + mosaic-end adapter strand minus its last 3 bases. The bead primer therefore primes on the S5-adapter end of tagmented fragments.

Final library and reads

P5PE1-derived end · hydrogel-oligo arm · barcode 1 (8–11 nt) · barcode linker · barcode 2 · bead Tn5-adapter arm · copied mosaic-end bases · single-microbe genomic DNA · mosaic end (rc) · Nextera i7 primer arm (rc) · i7 sample index · P7 (rc)

🟡 Sequencing: a custom Read-1 primer (IDT) is required. A 100-bp run uses Read 1 = 45 bp of barcode only, Index 1 = 8 bp and Read 2 = the remainder (microbial). A 300-bp run uses Read 1 = 150 bp (first 45 barcode, last 75 microbial). Because the custom primer sequence is not printed, the page gives a source-declared read table instead of a computed primer landing.

🔴 Not printed in the inspected preprint sources: the initiating hydrogel oligo, P5PE1, the custom Read-1 primer, the commercial MDA primers, and any opposite (S7-side) primer in the barcoding droplet. These are open questions, not confirmed absences.

Model corrections (2026-10-17 bounded pass)

Open questions