Oxford Nanopore Direct RNA Sequencing — SQK-RNA004

Protocol relationships

No curated ancestry links yet. This does not establish independent origins.

No formal ancestor assigned in this review. Considered earlier registered methods; no dated candidate was returned. The inspected Oxford Nanopore Direct RNA Sequencing RNA004 clauses identify We strongly recommend sequencing your library as soon as it is adapted. / Quantify 1 µl of reverse-transcribed and adapted RNA on a Qubit™ fluorometer using the Qubit™ dsDNA HS assay.. These candidates do not isolate the same specific chemical strategy from generic capture/priming/amplification or assay-output overlap; no single defensible earlier analogue is assigned in this capped pass.

Explore relationships and sequence similarity

Research notes

Commercial protocol: Oxford Nanopore Direct RNA sequencing (SQK-RNA004), DRS_9195_v4_revL_29June2026; architecture paper: Garalde et al. (2018).

The RT Adapter (RTA) is ligated to the RNA 3′ end with T4 DNA ligase, together with the optional RNA CS control strand. Induro reverse transcriptase then makes a stabilizing cDNA, and the hybrid is cleaned up on RNAClean XP beads. A second T4 DNA ligase step attaches the RNA Ligation Adapter (RLA) sequencing adapter, and the library is washed with WSB and eluted in REB. The nanopore reads the native RNA strand from its 3′ end toward 5′.

The inspected protocol sections give no bases for the RTA or RLA, no motor identity and no ligating-end geometry. Bracketed components below are structural roles, not invented bases. The protocol accepts 300 ng poly(A)-tailed RNA or 1 µg total RNA. That RTA targets poly(A) is inferred from this input requirement and from the technical document; the protocol does not print an oligo(dT) sequence.

Reaction workflow

motor-adapted native RNA library

native poly(A) RNA native RNA 5'- RNA body[RNA body]poly(A) tail[poly(A) tail] -3' RNA body poly(A) tail Present adapter and substrate ends source limitation 5'- adapter overhang not reported[adapter overhang not reported] -3' The vendor specifies RTA ligation to the RNA 3-prime end but withholds the current ligating-end sequence. Ligate RTA (and optional RCS) to RNA, 10 min room temperature [RTA-ligated native RNA] Synthesize the stabilizing cDNA, 60 °C 30 min then 70 °C 10 min [native RNA with stabilizing cDNA] Purify the RT reaction on RNAClean XP beads [bead-purified RNA–cDNA hybrid in 23 µl water] Present adapter and substrate ends source limitation 5'- adapter overhang not reported[adapter overhang not reported] -3' The vendor ligates RLA to the RNA-cDNA hybrid with T4 DNA ligase but does not disclose the adapter ends or junction. Ligate RLA to the RNA–cDNA hybrid, 10 min room temperature [RLA-ligated RNA–cDNA hybrid] Remove free adapter on RNAClean XP beads with WSB washes motor-adapted native RNA library 5'- motor-loaded sequencing adapter[motor + sequencing adapter]RLA/RTA boundary[RLA to RTA, junction undisclosed]RT Adapter (RTA)[RTA]native RNA:cDNA hybrid[native RNA with stabilizing cDNA] -3' motor-adapted native RNA library 3'- motor-loaded sequencing adapter'[motor + sequencing adapter]RLA/RTA boundary'[RLA to RTA, junction undisclosed]RT Adapter (RTA)'[RTA]native RNA:cDNA hybrid'[native RNA with stabilizing cDNA] -5'
  1. Present adapter and substrate ends. The vendor specifies RTA ligation to the RNA 3-prime end but withholds the current ligating-end sequence.
  2. Ligate RTA (and optional RCS) to RNA, 10 min room temperature. Inputs: reverse-transcription adapter; RNA CS (RCS) control strand, optional (yeast enolase II); T4 DNA ligase (2M U/ml) in NEBNext Quick Ligation buffer, with murine RNase inhibitor
  3. Synthesize the stabilizing cDNA, 60 °C 30 min then 70 °C 10 min. Inputs: reverse-transcription adapter; Induro reverse transcriptase with dNTPs
  4. Purify the RT reaction on RNAClean XP beads. Inputs: RNAClean XP beads (72 µl), 70% ethanol washes. Other outputs: RT supernatant and ethanol washes → discard
  5. Present adapter and substrate ends. The vendor ligates RLA to the RNA-cDNA hybrid with T4 DNA ligase but does not disclose the adapter ends or junction.
  6. Ligate RLA to the RNA–cDNA hybrid, 10 min room temperature. Inputs: RNA Ligation Adapter (RLA) sequencing adapter; T4 DNA ligase (2M U/ml) in NEBNext Quick Ligation buffer
  7. Remove free adapter on RNAClean XP beads with WSB washes. Inputs: RNAClean XP beads (16 µl), two 150 µl WSB washes, 13 µl REB elution. Other outputs: supernatant and WSB washes with free adapter → discard

Other material outcomes

RT supernatant and ethanol washes — discard

unbound RT reaction components removed with the bead supernatant

Molecular structure is not represented in this graph.

supernatant and WSB washes with free adapter — discard

free RLA and ligation components removed in the WSB washes

Molecular structure is not represented in this graph.

Final sequencing library

The motor presents native RNA from its poly(A)/3-prime end; cDNA is stabilizing material.
library 5'- motor-loaded sequencing adapter[motor + sequencing adapter]RLA/RTA boundary[RLA to RTA, junction undisclosed]RT Adapter (RTA)[RTA]native RNA:cDNA hybrid[native RNA with stabilizing cDNA] -3' library 3'- motor-loaded sequencing adapter'[motor + sequencing adapter]RLA/RTA boundary'[RLA to RTA, junction undisclosed]RT Adapter (RTA)'[RTA]native RNA:cDNA hybrid'[native RNA with stabilizing cDNA] -5' motor-loaded sequencing adapter RT Adapter (RTA) RLA/RTA boundary native RNA:cDNA hybrid

Sequencing entry

No sequencing primer extends this library. The motor-loaded sequencing adapter captures the RNA–cDNA hybrid at the pore and controls passage of the native RNA strand, beginning at its poly(A)/3′ end and proceeding toward the RNA 5′ end. The cDNA stabilizes the RNA but is not the strand base-called in direct-RNA mode.

Sequencing-primer binding on the final library
final library 5'- motor-loaded sequencing adapter[motor + sequencing adapter]RLA/RTA boundary[RLA to RTA, junction undisclosed]RT Adapter (RTA)[RTA]native RNA:cDNA hybrid[native RNA with stabilizing cDNA] -3' 3'- motor-loaded sequencing adapter[motor + sequencing adapter]RLA/RTA boundary[RLA to RTA, junction undisclosed]RT Adapter (RTA)[RTA]native RNA:cDNA hybrid[native RNA with stabilizing cDNA] -5' Read 1 primer: ? Direct RNA sequencing is motor-driven; current RTA and sequencing-adapter sequences are proprietary. Index primer: ? Direct RNA sequencing is motor-driven; current RTA and sequencing-adapter sequences are proprietary. Read 2 primer: ? Direct RNA sequencing is motor-driven; current RTA and sequencing-adapter sequences are proprietary.

Read content and handling

Nanopore sequencing is motor-driven and does not use a synthesis sequencing primer.

ReadCyclesContentInclude in sequence analysis?
Sequencing outputnot fixedOne strand enters from the RNA sequencing adapter end and reports native RNA:cDNA hybridYes — include in sequence analysis