Oxford Nanopore ligation sequencing V14 (SQK-LSK114)

1. What it is

Oxford Nanopore's standard ligation workflow repairs and dA-tails long double-stranded DNA, ligates motor-loaded sequencing adapters to both ends, and feeds one strand through a nanopore without PCR or a sequencing primer.

Commercial defining source: Oxford Nanopore, “Ligation sequencing gDNA V14 — SQK-LSK114,” GDE_9161_v114_revAC_24Sep2025.

2. Sources read

3. End preparation

🟢 NEBNext FFPE DNA Repair v2 and Ultra II End Prep act at 20 °C for 5 min and 65 °C for 5 min. The chemistry document states that repair/end prep produces uniform 5′ phosphates and single 3′ dA overhangs. The local explicit EndPreparedDuplex declaration records these as properties of both insert ends.

🟢 Input is 1 µg (or 100–200 fmol) DNA in 47 µl, with optional DNA Control Sample (a 3.6 kb lambda amplicon). After end prep, 60 µl AMPure XP beads bind the DNA; two 200 µl 80% ethanol washes and a 61 µl water elution follow.

4. Ligation Adapter

🟢 The current chemistry document prints the two disclosed LA oligos:

top     CCTGTACTTCGTTCAGTTACGTATTGCT
bottom  GCAATACGTAACTGAACGAAGTACAGG

🟡 The bottom is the reverse complement of the first 27 top-strand bases. The result is a 27-bp duplex with one top-strand 3′ dT overhang. The shared adapter constructor verifies that relationship and refuses an incompatible dA/dT ligation.

🟢 Ligation uses LA, Ligation Buffer and Salt-T4 DNA ligase for 10 min at room temperature (60 µl DNA, 5 µl LA, 25 µl LNB, 10 µl Salt-T4). The chemistry document says molecules with adapters (and tethers) on both ends are more potent than singly adapted ones. Cleanup uses 40 µl AMPure XP, two 250 µl washes with Long Fragment Buffer (enriches fragments of about 3 kb and longer) or Short Fragment Buffer (retains all sizes), and 15 µl Elution Buffer (37 °C can improve recovery of high-molecular-weight DNA). Ethanol must not be used here because it can denature the adapter motor protein.

🟡 Model correction (2026-10-17): the graph now includes both bead cleanups and their discarded supernatants. Earlier it went directly from end prep to ligation to sequencing.

5. Motor, tether and sequencing

🟢 LA is supplied with a motor protein. The motor associates with a nanopore, unzips the duplex and controls translocation of one intact strand. This is direct sequencing: there is no conventional sequencing primer.

🟢 Flow Cell Tether is mixed into the flow-cell priming solution and concentrates library at the membrane. The inspected SQK-LSK114 protocol, chemistry document and sensing explanation do not specify a covalent tether-to-library bond, so none is drawn.

🔴 The complete Y-shaped leader sequence, current motor identity, attachment chemistry, full tether structure and definitive strand polarity remain unverified in this source audit. The older sensing explanation describes motor-on-leader strand capture but is not a version-specific molecular inventory for SQK-LSK114. The page therefore shows a named unresolved leader/motor feature and does not invent bases or a covalent tether segment. An independent source check of that explanation and its links remains open before any absence claim can be accepted.

Native graph scope, 2026-10-18

Native graph migration (2026-10-18): source-qualified LA strands and the selected no-DCS genomic-DNA route are owned locally. Explicit prepared ends and paired adapter strands feed the ligation geometry; the terminal T is represented once. The 61 µl eluate is split into a 1 µl Qubit aliquot and 60 µl ligation input; measurement-aliquot fate is unresolved. The disclosed adapter DNA and sealed junctions are separate from the associated, unplaced motor/leader component. No protein or speculative leader is appended as a covalent DNA segment. The September 2025 workflow and July 2026 oligo reference retain distinct identities; they do not establish full historical reagent equivalence. Optional DCS is outside this selected no-control route. Source-known operation order and both physical cleanups remain explicit. This is a native graph migration within the stated source scope, not complete leader/motor validation or an accepted absence audit.

Independent implementation review retained unligated/partly adapted molecular classes and unresolved later bead recovery; ligation does not establish complete adaptation or physical purity. This code review read no additional originals and does not count as an independent second source-reading pass.