Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
Inferred adapter structure. The paper reports 96 × 90 barcoding-primer combinations; the exact Pi-ATAC well-to-primer assignment remains unassigned in this model. The authors’ detailed protocol names Ad1/Ad2 stocks and links the Buenrostro scATAC predecessor, whose Supplementary Table 1 prints a Nextera Ad1/Ad2 primer family. Which members Pi-ATAC used for its 96 × 90 wells remains unverified; dotted regions show this source boundary.
Published descriptions differ. The article Methods, “Index sorting and library preparation for Pi-ATAC” states 20 µl reverse-crosslink buffer, 65°C overnight and a 25 mM barcoding-primer stock. The author protocol, 23 October 2018, steps 26, 32 and 34 states 25 µl buffer, 60°C and 25 µM Ad1/Ad2 stocks. Protocol step 25 also prints proteinase K “200 µg/µl” alongside a 1:100 dilution of 20 mg/ml stock, which calculates to 200 µg/ml; the article’s buffer description instead prints 5 ng/ml. These are distinct source values, including an apparent internal unit error. This molecular schematic assigns none of these disputed concentrations, volumes or temperatures; it does not establish which conditions were performed.
Reaction workflow
inferred Pi-ATAC-seq library
Bind fluorescent antibodies to cellular proteins. Inputs: fluorescent protein-detection antibodies. Other outputs: unbound antibody wash fraction → discard
Tagment antibody-stained cells in bulk. Inputs: Nextera-compatible Tn5 transposome; Tn5 transposase. Other outputs: candidate non-library tagmentation products → unresolved
Record protein fluorescence and index-sort one cell per well. Inputs: one-cell-per-indexed-well FACS rule. Other outputs: empty wells and multiplet events → discard
Reverse crosslinks overnight at65°C; inactivate proteinase K at80°C for10min. Inputs: proteinase K reverse-crosslink reagent
Fill transposition gaps. Inputs: gap-fill and PCR polymerase
Amplify with well-specific barcoding primers: 20 cycles. Inputs: well-specific i5 barcoding primer; well-specific i7 barcoding primer; gap-fill and PCR polymerase
Other material outcomes
unbound antibody wash fraction — discard
unbound antibodies are removed before cytometric sorting
Molecular structure is not represented in this graph.
Amplification eligibility is not a demonstrated physical discard of candidate insertion products.
Molecular structure is not represented in this graph.
empty wells and multiplet events — discard
empty and multiplet sorting events are excluded
Molecular structure is not represented in this graph.
Molecular details
(1) Fix, antibody-stain, and tagment cells in bulk
INFERRED — standard ATAC s5/s7 geometry. Bound Tn5 keeps the tagged DNA inside each fixed cell for sorting.
(2) Index-sort one cell per well and reverse crosslinks
Protein abundance is recorded by FACS; it is not encoded in the DNA library.
(3) Gap-fill and amplify with the well’s barcoding-primer pair
INFERRED — Nextera-compatible final library, P5 to P7'. The Pi-ATAC well-to-primer assignments remain unassembled here; a cited predecessor publishes related Ad1/Ad2 primer families.
Sequencing
Paired-end 2 × 75 with two per-well index reads. Primer landing sites below are computed for the inferred Nextera-compatible structure.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
anneals to the top strand over ME reverse complement, s7 reverse complement
xxxxxxxxxxxx… (from accessible genomic DNA)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.
Read
Cycles
Content
Include in sequence analysis?
Read 1
75
accessible genomic DNA (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end
Yes — include in sequence analysis
Index 1 (i7)
8
sample index (cycles 1–8)
No — use for sample demultiplexing
Index 2 (i5)
8
sample index (cycles 1–8)
No — use for sample demultiplexing
Read 2
75
accessible genomic DNA (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end