PicoPLEX DNA-seq — quasi-random preamplification with dual indexing
Protocol relationships
No curated ancestry links yet. This does not establish independent origins.
No formal ancestor assigned in this review. The manual attributes chemistry to patented Rubicon PicoPLEX technology, but no separate earlier protocol/source identity with verified chronology is established. MALBAC-like comparisons would require more than the common WGA objective.
Single-cell DNA is lysed, copied through 12 cycles of proprietary quasi-random priming and linear amplification, then exponentially amplified in the same tube with one of 48 dual-index pairs. The indexed libraries are pooled and purified once on AMPure XP beads.
The manual prints the 8-nt i5/i7 index sequences but withholds the quasi-random primer, common-handle and complete adapter sequences. Those regions are shown by role, without bases.
PicoPLEX DNA-seq Instruction Manual QAM-106-002, Analysis of the Sequencing Reads (p. 15): the first 11 cycles of each read contain quasi-random bases
PicoPLEX DNA-seq Instruction Manual QAM-106-002, Analysis of the Sequencing Reads (p. 15): trim the initial 14 bases from each read or begin at base 15
Modelled: The library shows 11-nt quasi-random primer-derived regions at both insert ends; the read table follows the manual's 14-base trim. Evidence: Both numbers appear in the same paragraph of the manual. Remaining uncertainty: The manual does not explain the extra three trimmed bases (for example a fixed primer segment or a safety margin).
Purified-DNA input range is worded two ways.
PicoPLEX DNA-seq Instruction Manual QAM-106-002, Starting Material: Genomic DNA (p. 6): small amounts (less than 6 pg to 60 pg) of purified genomic DNA
PicoPLEX DNA-seq Instruction Manual QAM-106-002, Cell Lysis Protocol step 1 (p. 8): cells (1 to 10) or DNA (6-60 pg)
Modelled: The model uses the protocol-step range 6–60 pg; the positive control uses 15 pg. Evidence: Both statements are in the same manual revision. Remaining uncertainty: Whether inputs below 6 pg are supported is not stated elsewhere in the manual.
As printed in manual Figures 4 and 7. The manual does not say which strand these sequences are written on, and it gives no full primer sequences.
Reaction workflow
AMPure-purified pooled PicoPLEX library
Lyse cells and release genomic DNA. Inputs: Cell Extraction Buffer + Extraction Enzyme Dilution Buffer/Cell Extraction Enzyme master mix; 75 °C 10 min, 95 °C 4 min, 22 °C hold (10 µL)
Multiple cycles of quasi-random priming and linear amplification. Inputs: proprietary quasi-random primers in Pre-Amp Buffer; Pre-Amp Enzyme (identity and strand-displacement activity not stated); same tube, 15 µL: 95 °C 2 min; 12 × (95 °C 15 s, 15 °C 50 s, 25 °C 40 s, 35 °C 30 s, 65 °C 40 s, 75 °C 40 s); 4 °C hold
Exponentially amplify and install the unique dual indexes. Inputs: 8-nt i5 indexed amplification primer (Dual Index Plate row, D501–D508); 8-nt i7 indexed amplification primer (Dual Index Plate column, D701–D706); Amplification Buffer + Amplification Enzyme; same tube, 50 µL (optional EvaGreen/fluorescein): 95 °C 4 min; 4 × (95 °C 20 s, 63 °C 25 s, 72 °C 40 s); 7 × (95 °C 20 s, 72 °C 55 s); 4 °C hold
Pool 10 µL of each indexed library. Additional template inputs: other PicoPLEX libraries, each with a different dual-index pair (up to 48 in all)
Purify the pool on AMPure XP beads. Inputs: AMPure XP 1:1 (100 µL + 100 µL pool), two 80% ethanol washes, 50 µL TE elution. Other outputs: supernatant and washes with unincorporated primers → discard
Other material outcomes
supernatant and washes with unincorporated primers — discard
unincorporated primers and reagents removed with the bead supernatant
Molecular structure is not represented in this graph.
Final sequencing library
Illumina-compatible dual-index library as the manual describes it. Bracketed regions are proprietary. The manual does not give enough bases to compute where the sequencing primers land. Libraries are ~300–1000 bp in total (~200–900 bp inserts).
Sequencing entry
The purified pool is sequenced with standard Illumina reagents for multiplexed libraries (starting point: 16 pM on MiSeq v3 with at least 5% PhiX). The exact primer landing bases are not disclosed, and the manual sets no read lengths.
Sequencing limitation. Illumina compatibility and dual indexes are published, but primer landing bases are not.
Sequencing-primer binding on the final library
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
not fixed
first 11 cycles quasi-random primer bases (manual: trim 14), then genomic insert
Yes — include in sequence analysis
Index 1 (i7)
8
i7 sample index (D701–D706)
No — use for sample demultiplexing
Index 2 (i5)
8
i5 sample index (D501–D508)
No — use for sample demultiplexing
Read 2
not fixed
first 11 cycles quasi-random primer bases (manual: trim 14), then genomic insert from the opposite end