Pseudo-seq

Defining source: Carlile et al., Nature (2014), doi:10.1038/nature13802. The open author manuscript (PMC4224642, NIHMS624208; JATS cached as nature13802_PMC4224642.xml) was read; the publisher version of record is paywalled (manual row in the source manifest). Nature supplementary information (MOESM55_ESM.pdf, table legends) and source-data workbooks were inventoried.

2026-10-17 bounded pass (round breadth-first-15), JATS text lines: Methods “Pseudo-seq Library Preparation” 56 (RNA isolation, polyA selection, Zn fragmentation), 58 (CMC/reversal/mock), 60 (CIP/PNK, PAGE fractions, adapter ligation), 62 (AMV-RT, RT primer, cDNA gel), 64 (CircLigase, Phusion PCR primers, HiSeq 2000); Results 24/26 and Extended Data Fig. 2 legend (alternative SuperScript III, fragment sizes, CMC dose); data deposition line 234 (GEO GSE58200). Read length and acquired cycles were not found in these passages.

Evidence used

Published library oligos

The open author manuscript's “Pseudo-seq Library Preparation” Methods (PMCID PMC4224642) prints these oligos. Modifications and the unknown six-base sample index are retained as written.

Role5′→3′ ordered oligoEvidence
3′ RNA adapter/5Phos/TGGAATTCTCGGGTGCCAAGG/3ddC/🟢 Methods; described there as pre-adenylated, although the printed IDT string says /5Phos/
RT primer/5Phos/GATCGTCGGACTGTAGAACTCTGAACCTGTCGGTGGTCGCCGTATCATT/iSp18/CACTCA/iSp18/GCCTTGGCACCCGAGAATTCCA🟢 Methods
PCR forwardAATGATACGGCGACCACCGA🟢 Methods
PCR reverseCAAGCAGAAGACGGCATACGAGATXXXXXXGTGACTGGAGTTCCTTGGCACCCGAGAATTCCA🟢 Methods; X is a variable sample index

Published adapter discrepancy. The same Methods paragraph calls the 3′ adapter “pre-adenylated” but writes its ordered form with /5Phos/. A 5′ phosphate and a 5′ adenylate are distinct chemical states. The model uses the printed bases and modification string and follows the described ligation step; the source does not establish whether the ordered or reacted adapter carried an adenylate. 🟡 The ATP-free ligation buffer is consistent with an adenylated donor; it is not a statement of the ordered modification.

🟡 The paper reports an Illumina HiSeq 2000 run and no separate custom sequencing-primer oligo. Its PCR primers and adapter establish the library chemistry, but the current role-level final construct does not yet compute an exact sequencing-primer binding coordinate.

Construct logic

Pseudo-seq reads a reaction endpoint rather than the modified base itself. The informative coordinate is the end of a truncated cDNA, and enrichment over the −CMC control distinguishes the chemical signal from ordinary RT stops.

Open questions

Local validation migration (2026-10-18)

Re-read published author manuscript PMC4224642 Methods lines 54–64; ran the source scraper and checked all four modified primer/adapter strings directly. The graph separates Zn fragmentation, CMC derivatization, alkaline reversal, CIP/PNK repair, RNA PAGE selection, reported ligation, AMV-RT, truncated-cDNA selection, CircLigase, Phusion PCR and final gel purification/precipitation. The mock-treated preparation remains the source comparison; it is not converted into CMC-modified RNA.

The adapter includes the terminal dideoxyC nucleotide. The RT primer preserves both non-nucleotide /iSp18/ spacers; its 22-base 3′ region is paired by computation with the full printed adapter, including that ddC nucleotide. Exact PCR primers and the six-base sample-index window are explicit inputs. The published phosphate versus adenylate discrepancy remains visible and its reacted donor state unresolved.

The spacer-containing circle and exact PCR path remain unassembled. PCR uses that actual circle boundary rather than the expected library as its geometry template. Read type/cycle counts/sequence-primer landing remain unassigned. These source and geometry boundaries remain open; no publication-wide absence conclusion is made.