sc-end5-seq
Defining source: doi:10.1101/2021.04.04.438388.
Molecular boundary
🟢 Oligo(dT)-primed and random-hexamer-primed variants use 10x-compatible template switching to preserve transcript 5′ ends with cell barcodes and UMIs.
Evidence boundary
🟢 The defining source is a preprint. Both published priming variants are shown and neither is silently chosen as canonical.
Primer evidence
🟢 The preprint's library-preparation methods (extracted PDF lines 1409–1457) give the actual 5′-assay RT primers. sc-end5-dT uses 5′-AAGCAGTGGTATCAACGCAGAGTAC-T(30)-VN-3′; sc-end5-rand uses 5′-AAGCAGTGGTATCAACGCAGAGTACNNNNNN-3′. The run used 75 + 75 bases. Both published sequences now appear as exact primer inputs in the reaction graph and in the page's oligo list; the poly(dT) shorthand expands to 30 thymidines in the model.
🟢 The nearby template-switch oligo 5′-AAGCAGTGGTATCAACGCAGAGTACATrGrGrG-3′ is explicitly described for the sc-end3-dT control made with the Chromium 3′ Reagent Kit v2. The two sc-end5 variants use the initial Chromium 5′ Library and Gel Bead Kit; the preprint does not give the exact oligo carried by those 5′ gel beads. The 3′-kit oligo must not be substituted for the 5′-kit bead oligo.
🟢 Official 10x CG000086 Rev K (2019) covers the same 5′ Library & Gel Bead Kit product numbers PN-1000006/1000014 and prints the Read 1–16-base barcode–10-base UMI–TSO bead oligo, RT product, Read 2 adapter and i7 PCR family in its appendix. Two independent readings of that later original are recorded in the source checklist. It is a same-kit architecture comparator, not proof of the exact guide revision used for the sc-end5 experiments.
🟡 The preprint names a kit cDNA primer mix and i7 sample-index plate but does not state the exact kit revision or which i7 well each library used. Those run-specific details remain blocked in the source review. The preprint reports 75-base paired-end sequencing; a version-matched guide and run assignment would be needed to place the original experiment's exact primer and index reads.
Reaction order and run details (2026-10-17 bounded pass)
🟢 Source identity: bioRxiv v2 (posted 21 April 2021), Moody, Kouno et al., "Profiling of transcribed cis-regulatory elements in single cells". No published version of this preprint was identified in this pass; the later tCRE-atlas paper by the same group is a separate study and was not used.
🟢 Methods (PDF text lines 1380–1440): sc-end5 cells were loaded on Chip A with the initial Chromium Single Cell 5′ Library and Gel Bead Kit; the random primer was used at 17 µM; RT ran in droplets at 53 °C for 45 min; cDNA was amplified with the kit cDNA primer mix for 12 (sc-end5-dT) or 14 (sc-end5-rand) cycles, "followed by the standard steps according to manufacturer's instructions"; libraries took different i7 sample-index plate indexes and were sequenced on a HiSeq 2500 as 75-base paired reads (PBMC sc-end5-dT likewise, lines 1440–1460). The model now draws the cDNA PCR as its own step and the unspecified kit steps as a warned unresolved boundary, followed by the index PCR. Splitting the cDNA primer mix into one primer per cDNA end is 🟡 inferred.
🟢 Methods "Removing strand invasion artifacts" (lines ~1790–1815) aligns genomic sequence to the TS-oligo sequence TTTCTTATATGGG, and the unencoded-G procedure (lines ~1740–1785) looks for its last 5 nt (ATGGG) before the soft-clipped junction. This is the only sc-end5 bead-oligo sequence the preprint prints; it is written as DNA read sequence, so the bead oligo's 5′ portion and terminal ribonucleotides are not given there. It matches the 3′ end of the CG000086 Rev K bead TSO comparator (…TTTCTTATATrGrGrG). Strand-invader removal is a computational filter, not a physical separation.
🔴 Still open: exact kit guide revision, cDNA primer bases, fragmentation/adapter steps, chosen i7 wells, and acquired index-read cycles.
Local chemistry ownership migration — 2026-10-18
Removed the queued shared endpoint recipe and its assumed eight-base sample index. Cell barcode, UMI and i7 roles now belong to this protocol and retain unassigned original-implementation lengths. Both source variants keep the 53 °C RT and the 12/14-cycle cDNA PCR. Its geometry points to the switched-cDNA substrate; primer footprints remain unassigned. The subsequent standard kit route ends at an explicit library boundary, without adding a generic terminal PCR after an unreviewed kit workflow. Each branch carries the source-stated 75/75 HiSeq acquisition. This source-qualified boundary does not assert that kit chemistry was unpublished. CG000086 Rev K remains a comparator.
Re-read one original: bioRxiv v2 Methods lines 1381–1457; the bundle scraper was run and the exact primer/control distinctions checked. No new absence audit or source-version equivalence claim is made.