scDNase-seq (Pico-Seq) and scMNase-seq — nuclease digestion of one cell, then a plain ligation library
Evidence marking. 🟢 verbatim from the source · 🟡 derived or inferred · 🔴 not published. Relationships marked 🟡 (computed) were worked out with
lib/while writing this note. They are not asserted in a self-test because the primary papers do not print the oligo sequences.Important for these protocols: neither defining paper prints a library oligo. Pico-Seq's cited library method identifies the exact historical Illumina kit, whose oligos are vendor-published and therefore 🟢 below. scMNase-seq only points to an older universal-adapter method; its reconstructed endpoint remains 🟡.
scDNase-seq (the paper calls it Pico-Seq) — Jin W, Tang Q, Wan M, Cui K, Zhang Y, Ren G, Ni B, Sklar J, Przytycka TM, Childs R, Levens D, Zhao K. "Genome-wide detection of DNase I hypersensitive sites in single cells and FFPE tissue samples." Nature 528, 142–146 (2015). doi:10.1038/nature15740 · PMC4697938. Data: GEO GSE61844 (Pico-Seq and RNA-seq).
scMNase-seq — Lai B, Gao W, Cui K, Xie W, Tang Q, Jin W, Hu G, Ni B, Zhao K. "Principles of nucleosome organization revealed by single-cell micrococcal nuclease sequencing." Nature 562, 281–285 (2018). doi:10.1038/s41586-018-0567-3 · PMC8353605. Data: GEO GSE96688.
Both from Keji Zhao's lab (NHLBI). The library-construction step of each paper points to an earlier lab paper instead of describing it: Pico-Seq to Hu et al. 2013 Nat Immunol (doi:10.1038/ni.2712, ref. 29), scMNase-seq to Barski et al. 2007 Cell (doi:10.1016/j.cell.2007.05.009, ref. 33). Hu et al. was fetched and identifies Illumina Multiplexing Sample Prep Oligonucleotide Kit ref. 1005709. Barski's exact adapter/index bases remain unavailable.
Sources read (fetched by tools/get_sources.py, into $CHEM_DATA/sources/scdnase-seq__10.1038+nature15740/, never committed):
| File | What | Used for |
|---|---|---|
upstream_scDNase_scMNase.html.txt | scg_lib_structs page (both methods) | inspiration only, not a source — it supplied no base used here (see “Oligo provenance”); orientation in the chemistry while reading the papers |
nature15740_PMC4697938.html.txt | Pico-Seq paper, PMC author manuscript with Methods | DNase I digestion, carrier DNA, two-step PCR, size selection, sequencer |
nature15740_41586_2015_BFnature15740_MOESM35_ESM.pdf.txt | Pico-Seq Supplementary Information | only the technical-repeat design (one cell's worth split in two); no chemistry |
nature15740_..._MOESM36..40_ESM.xls | Pico-Seq Supplementary Tables | read via a LibreOffice CSV conversion in scratch: GO enrichment tables and a VCF — not chemistry |
nature15740_..._MOESM31..34_ESM.ppt | Pico-Seq supplementary slides | catppt returns no text (image-only); not used |
s41586-018-0567-3_PMC8353605.html.txt | scMNase-seq paper (main text; Methods say "see Supplementary Methods") | cell numbers, fragment-size classes |
s41586-018-0567-3_41586_2018_567_MOESM1_ESM.pdf.txt | scMNase-seq Supplementary Information | all scMNase-seq wet-lab methods |
s41586-018-0567-3_..._MOESM3_ESM.xlsx.txt, MOESM4_ESM.xlsx.txt | per-library QC stats, dataset accessions | library counts; not chemistry |
s41586-018-0567-3_..._MOESM2_ESM.pdf.txt | Reporting Summary | not chemistry |
| Hu et al. 2013, doi:10.1038/ni.2712 | Pico-Seq's cited library method | identifies Illumina Multiplexing Sample Prep Oligonucleotide Kit ref. 1005709 |
| Illumina adapter-sequence guide | authoritative vendor document | obsolete Multiplexing-kit adapter and sequencing-primer bases |
Could not be fetched (listed (manual) in MANIFEST.tsv):
| File | URL | Matters? |
|---|---|---|
| Pico-Seq PMC supplement | https://pmc.ncbi.nlm.nih.gov/articles/instance/4697938/bin/NIHMS723562-supplement-1.pdf | maybe — may duplicate MOESM35, but could hold library details 🔴 |
| scMNase-seq Supplementary Methods (PMC copy) | https://pmc.ncbi.nlm.nih.gov/articles/instance/8353605/bin/NIHMS1727380-supplement-1727380_SupMethod.pdf | probably the same text as MOESM1 |
| scMNase-seq Sup. Tables 1–2 (PMC copy) | https://pmc.ncbi.nlm.nih.gov/articles/instance/8353605/bin/NIHMS1727380-supplement-1727380_SupTab1.xlsx , ..._SupTab2.xlsx | probably the same as MOESM3/4 |
| Barski et al. 2007 (the cited library protocol for scMNase-seq) | https://doi.org/10.1016/j.cell.2007.05.009 | yes, same reason |
1. What it is
Not a barcoding method. One FACS-sorted cell per PCR tube; the chromatin of that cell is cut by a nuclease in the tube, the DNA is purified, and a completely ordinary end-repair / A-tail / T-overhang-adaptor ligation library is made from it. The cell's identity is the sample index on the PCR primer, one library per cell. No cell barcode, no UMI, no Tn5. 🟢 (Pico-Seq Methods; scMNase-seq Supplementary Methods) / 🟡 (that the index is the only cell label — upstream says so; the papers just say "index primers").
The two methods differ only in the nuclease and what it reports 🟢:
| scDNase-seq / Pico-Seq (2015) | scMNase-seq (2018) | |
|---|---|---|
| Nuclease | DNase I — cuts accessible DNA (DHSs) | micrococcal nuclease — eats linker DNA, leaving nucleosome cores (140–180 bp) and sub-nucleosomal particles (≤ 80 bp, TF footprints / accessible sites) |
| Readout | DHS presence per cell | nucleosome positions and accessibility in one experiment |
| Carrier DNA | 30 ng circular plasmid added with the stop buffer | not mentioned in the methods 🔴 |
| PCR | two-step: 6 cycles index primers → gel 160–300 bp → 22 cycles P5/P7 | one step: 23 cycles with indexed primers → gel 160–300 bp |
| Cells | 5 NIH3T3 + 14 mESC single cells (38 Pico-Seq libraries incl. pools and FFPE) | 48 NIH3T3, 198 mESC, 278 naïve CD4 T cells |
| New thing here | Where else it turns up | |
|---|---|---|
| 1 | Circular carrier DNA (Pico-Seq): 3 × 10⁷-fold excess of plasmid protects the < 0.001 pg of DHS DNA from loss during extraction and ligation; being circular it has no ends, so it cannot take an adaptor and is (mostly) not amplified 🟢 | carrier RNA / glycogen in low-input kits; linear carrier would be ligated and sequenced |
| 2 | Two-step PCR with gel cut in between to favour short DHS fragments over carrier background 🟢 | — |
| 3 | Nuclease digestion of a single cell in its own tube, then a bulk-style library | later superseded by Tn5 (scATAC) and combinatorial indexing; see Tn5 tagmentation for the end-joining alternative |
Even with the carrier trick, only ~2 % of single-cell Pico-Seq reads map to the genome — the rest is amplified carrier (1000-cell libraries: ~40 %). 🟢 (Pico-Seq Methods, data analysis)
2. Oligos
For Pico-Seq, 🟢: the paper does not describe library construction but cites Hu et al. (doi:10.1038/ni.2712), which identifies Multiplexing kit ref. 1005709, and Illumina publishes that obsolete kit's sequences. Every base below is therefore a vendor-document Illumina part, taken in tools/scdnase_seq.py from lib/illumina.py rather than retyped; the i7 window is a placeholder. For scMNase-seq, the same layout remains 🟡: neither the defining paper nor the cited Barski method establishes the precise indexed oligo set, and nothing else on disk does either. Notation: /Phos/ = 5' phosphate, * = phosphorothioate bond, [i7] = sample index.
Illumina adaptor top /Phos/ GATCGGAAGAGCACACGTCT
Illumina adaptor bottom ACACTCTTTCCCTACACGACGCTCTTCCGATCT
Illumina PCR Primer 1.0 AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATC*T
Illumina Multiplexing PCR Primer CAAGCAGAAGACGGCATACGAGAT[i7]GTGACTGGAGTTCAGACGTGTGCTCTTCCGATC*T
Illumina P5 adapter AATGATACGGCGACCACCGAGATCTACAC
Illumina P7 adapter CAAGCAGAAGACGGCATACGAGAT
TruSeq Read 1 primer ACACTCTTTCCCTACACGACGCTCTTCCGATCT
TruSeq Read 2 primer GTGACTGGAGTTCAGACGTGTGCTCTTCCGATCT
Sample index sequencing primer GATCGGAAGAGCACACGTCTGAACTCCAGTCAC
What the papers do say: Pico-Seq — "Illumina kits", first PCR with "index primers", second PCR with "the P5 and P7 primers"; its cited Hu method supplies the missing kit identity. scMNase-seq says only "Universal adaptors" and "indexed primers". The exact scMNase-seq index catalogue and length are not given. 🔴
How they interlock — 🟡 (computed with lib/illumina)
- Adaptor bottom =
illumina.TRUSEQ_READ1exactly (33 nt), ending in the 3' T overhang. - Adaptor top =
illumina.INDEX1_PRIMER[:20](20 nt), starting withillumina.STEMGATCGGAAGAGC. - Annealed, the two oligos pair only over 12 bp: top[1–12]
GATCGGAAGAGCwith the bottom's 3'GCTCTTCCGATC, leaving a single 3'-T overhang on the bottom, a 20-nt unpaired 5' arm on the bottom (ACACTCTTTCCCTACACGAC) and an 8-nt unpaired 3' arm on the top (ACACGTCT). A Y (forked) adaptor; upstream draws it this way. - After T/A ligation each insert strand reads
5'- TRUSEQ_READ1 · insert(+A) · adaptor top -3'. Its 3' endA·GATCGGAAGAGCACACGTCTis complementary to the last 21 nt ofTRUSEQ_READ2— that is where the Multiplexing PCR Primer anneals. - PCR Primer 1.0 =
illumina.P5+TRUSEQ_READ1[4:](58 nt; P5 ends and Read 1 starts with the sameACAC, so they overlap by 4) — identical toillumina.NEBNEXT_UNIVERSAL_PRIMER. It is the same sense as the ligated strand's 5' end, so it cannot prime on the ligation product; it primes only on the strand made by the Multiplexing primer. (Upstream says the same: "no place to anneal" in round 1.) - Multiplexing PCR Primer =
illumina.P7+ i7 +illumina.TRUSEQ_READ2— 58 nt plus the index (64 nt with a 6-nt index). - Sample index sequencing primer =
illumina.INDEX1_PRIMER= revcomp(TRUSEQ_READ2) without its 5'A, and it begins with the 20-nt adaptor top. - P5 / P7 adapter =
illumina.P5/illumina.P7— the second-round primers of Pico-Seq's two-step PCR.
3. Step by step
scDNase-seq / Pico-Seq — 🟢 (Pico-Seq Methods)
- Sort single live (DAPI-negative) cells into PCR strip-tubes holding 30 µL lysis buffer: 10 mM Tris-HCl pH 7.5, 10 mM NaCl, 3 mM MgCl₂, 0.1 % Triton X-100.
- DNase I: 0.2–1 U (Roche), 37 °C 5 min.
- Stop + carrier: 80 µL stop buffer (10 mM Tris pH 7.5, 10 mM NaCl, 0.15 % SDS, 10 mM EDTA) carrying 1 µL proteinase K (20 mg/mL) and 5 µL of 6 ng/µL circular carrier DNA (30 ng). 55 °C 1 h.
- Purify: phenol–chloroform, ethanol precipitation with 20 µg glycogen.
- Library "using Illumina kits as described" (Hu 2013). The paper's Fig. 1a legend names end repair, adaptor ligation and PCR; A-tailing is not stated but is implied by the T-overhang adaptor 🟡 (upstream lists it).
- PCR 1, index primers: 6 × (98 °C 10 s, 67 °C 30 s, 72 °C 30 s). The circular carrier is still present; it has no adaptor so is not exponentially amplified. 🟡
- Gel: isolate 160–300 bp on a 2 % E-gel.
- PCR 2, P5 + P7 primers: 22 × (98 °C 10 s, 68 °C 30 s, 72 °C 30 s).
- Gel again, 160–300 bp; sequence on HiSeq 2500.
FFPE variant 🟢: cells scraped from the marked slide area, deparaffinised (Qiagen solution, 56 °C 3 min), lysis buffer 37 °C 2 h, DNase I as above, then crosslink reversal 65 °C overnight before purification and library prep.
scMNase-seq — 🟢 (Supplementary Methods, MOESM1)
- Sort single live cells into PCR strip-tubes holding 32 µL lysis buffer: 10 mM Tris-HCl pH 7.5, 10 mM NaCl, 3 mM CaCl₂ (MNase is Ca²⁺-dependent 🟡), 0.1 % Triton X-100.
- MNase: 8 µL MNase diluted 1:3000 in lysis buffer, 37 °C 5 min. (Titration experiment: three groups of 10 NIH3T3 single cells at different MNase amounts; the Supplementary Methods text names 0.6 and 2.4 U per million cells, and the titration sheet of Supplementary Table 1 labels a group "0.1U" — the spacing conclusions held in both conditions compared.)
- Stop: 80 µL stop buffer with 10 mM EGTA (Ca²⁺ chelator, in place of Pico-Seq's EDTA) and 1 µL proteinase K (20 mg/mL); 55 °C 1 h.
- Purify: phenol–chloroform, ethanol precipitation with glycogen. No carrier DNA is mentioned. 🔴 (whether it was omitted or just not written)
- Ligate "Universal adaptors" "as described" (Barski 2007).
- PCR, indexed primers: 23 × (98 °C 10 s, 67 °C 30 s, 72 °C 30 s). No second PCR.
- Gel: 160–300 bp on E-gel; paired-end sequencing on HiSeq 2500.
Note on the size window 🟡: a 160–300 bp library minus 122 nt of adaptor/primer (computed for a 6-nt i7, §4) is an insert of roughly 40–180 bp — exactly the sub-nucleosomal (≤ 80 bp) to mono-nucleosome (140–180 bp) range scMNase-seq analyses, and it excludes di-nucleosomes.
4. Final library
For Pico-Seq this is computed from the identified vendor kit (🟢 source, 🟡 assembly); for scMNase-seq it remains an upstream-supported reconstruction (🟡):
5'- P5 · TruSeq Read 1 (minus its first 4 nt, shared with P5) · <insert> · A · INDEX1_PRIMER (= TruSeq Read 2') · <i7'> · P7' -3'
As lib/ names, top strand: illumina.P5 + illumina.TRUSEQ_READ1[4:] + insert + "A" + illumina.INDEX1_PRIMER + revcomp(i7) + illumina.P7_RC. Fixed part 122 nt with a 6-nt i7 (29 + 29 + 34 + 6 + 24). The A before GATCGG… is the A-tail; strictly it pairs with the adaptor's 3' T, so the insert's genomic sequence is bounded by the T on one side and the A on the other. 🟡
Agreement with upstream: identical, including the 6-nt i7 placeholder NNNNNN. The six-base width is defined for the historical Multiplexing kit used by Pico-Seq; for scMNase-seq it is only the upstream reconstruction. 🟡
5. Sequencing
- 🟢 HiSeq 2500 for both. scMNase-seq: paired-end (fragment length is the readout). Pico-Seq: reads handled "if pair-end sequencing was performed" — so at least some Pico-Seq libraries were paired-end, some apparently single-end. 🟢 Read lengths: not given. 🔴
- Pico-Seq: 🟢 historical Multiplexing-kit Read 1, Index 1 and Read 2 primers; one six-base i7 identifies the library, and there is no i5. scMNase-seq: the same three-primer placement is 🟡 because its exact adapter/index set is unresolved.
- 🟢 Mapping detail: unmapped single-cell and low-input Pico-Seq reads were iteratively trimmed by 5 bp and re-aligned, until shorter than 26 bp. 🟡 (our reading) This is consistent with short DHS inserts read through into the adaptor.
6. Agreements and disagreements with upstream
The scg_lib_structs page is inspiration, not a source: its claims are treated here as hypotheses checked against the papers, and an "agrees" verdict records that the papers say so, never that upstream corroborates anything.
| Upstream claim | Papers | Verdict |
|---|---|---|
| Both methods use "almost the same procedures" | yes — same lysis/stop/purification/gel; nuclease, divalent cation and chelator differ | agrees 🟢 |
| Carrier plasmid is "the trick" for both | stated only for Pico-Seq; absent from scMNase-seq methods | partly disagrees 🔴 |
| End repair and A-tailing | Pico-Seq says end repair; A-tailing not stated in either | plausible 🟡 |
| Oligo sequences (TruSeq Y adaptor, PCR Primer 1.0, Multiplexing PCR Primer) | papers name only "Illumina kits", "index primers", "Universal adaptors", "P5 and P7 primers" | consistent, unverifiable 🟡 |
| One PCR with PCR Primer 1.0 + Multiplexing PCR Primer | Pico-Seq used two PCRs (6 cycles index primers, gel, 22 cycles P5/P7); scMNase-seq one PCR of 23 cycles | upstream fits scMNase-seq; for Pico-Seq it omits the second, short-primer PCR 🟡 |
| i7 is 6 nt and is the cell barcode | papers: one library per cell with index primers; length not given | plausible 🟡 |
| "Incubate nuclei" | cells are sorted into a Triton-containing lysis buffer and digested there | agrees in effect 🟡 |
7. Open questions
- 🔴 Which exact adapter and indexed-primer set scMNase-seq used; Barski 2007 does not publish enough sequence detail to establish it.
- 🔴 Was carrier DNA used in scMNase-seq? The 2018 methods do not mention it, while the 2015 paper presents it as essential.
- 🔴 The identity of the circular carrier plasmid (not named), and whether linearised carrier molecules (nicked/broken plasmid) are the source of the ~98 % non-mapping single-cell reads.
- 🔴 Pico-Seq second-round "P5 and P7 primers": the short 29/24-nt P5/P7 oligos upstream lists, or full-length primers? The upstream final library is the same either way.
- 🔴 Read lengths and read configuration per library.
8. How this note was made (tool evaluation)
tools/get_sources.py fetched both PMC full texts, the Springer supplements, and the Hu et al. paper cited for Pico-Seq's library construction; the Pico-Seq PMC supplement and the scMNase-seq PMC copies sat behind the download gate. tools/doctext.py made no .txt twins for the legacy .xls (BIFF) and .ppt files; the .xls were read via a LibreOffice CSV conversion in scratch (GO tables and a VCF, no chemistry), the .ppt gave no text. tools/scrape_primers.py found the library oligos in the upstream page (all recognised against lib/illumina); the biological papers contain only unrelated Sanger, ChIP-qPCR and EMSA/reporter oligos. Pico-Seq's promotion rests on the cited Hu method's exact kit reference plus Illumina's vendor sequence table, not on sequence text in the paper. scMNase-seq remains 🟡 because that source chain does not identify its indexed set.
Bounded curation round 2 (2026-10-16)
Inspected: Published original PMC4697938 JATS117–125.
Added6-cycle index PCR,160–300bp E-gel selection and22-cycle P5/P7 PCR labels. Public page records30ng circular carrier, PK/extraction and final repeated160–300bp selection as currently summarized graph scope. Replaced inferred acquired paired/index reads with unassigned HiSeq2500 mask.
Deferred: Cited library method29 and original vendor kit; explicit carrier/recovery/final-selection graph stages, exact acquisition and all oligo assignments. This capped pass does not establish a complete source review or publication-wide absence.
Source-owned graph migration, 2026-10-18
Replaced shared nuclease_accessibility recipe with a local scDNase graph. Added source-described30ng circular carrier, SDS/EDTA stop/proteinaseK, DNA extraction/ethanol recovery and the second160–300bp E-gel selection; the final library is the second gel product. Carrier-derived background stays unresolved rather than being silently discarded. Corrected repository indexed-primer transcription: vendor members end with13nt GTGACTGGAGTTC, not full34nt Read2. The exact early primer-extension route is not asserted; first-PCR geometry uses the actual ligated precursor. Second-round P5/P7 inputs stay distinct with physical sequences unassigned. dA-tail reference is explicitly inferred from adapter compatibility. Acquisition is explicitly unspecified instead of silently acquiring every declared kit primer.
Source scope: Jin etal.2015 published article PMC4697938 JATS Methods lines117–121 and analysis line153; Illumina Adapter Sequences1000000002694 v22 obsolete Multiplexing kit pp100–101, extracted lines22679–22725.
Deferred: Cited Hu etal. ni.2712 method not re-read in this bounded pass; prior source/version assignment is preserved; Exact physical first-PCR mixture/extension route and second-round P5/P7 oligos remain unassigned; Carrier plasmid identity, precise background products and study run mask remain unresolved. This bounded check accepts no missing-information claim.
Molecular population display correction (2026-10-18)
Genomic fragments and independently added circular carrier occupy separate Scene rows in stopped/recovered material. Fork-adapted target fragments and unresolved carrier background also occupy separate rows at the first PCR input. This does not assign carrier-derived product chemistry. This implementation-only correction reuses the original migration source scope; no additional originals were read and no new chemistry or missing-information conclusion is asserted.