sci-ATAC-seq3 — research note

Domcke S, Hill AJ, Daza RM et al. A human cell atlas of fetal chromatin accessibility. Science 370:eaba7612 (2020). doi:10.1126/science.aba7612 (PMC7785298, author manuscript).

The earlier combined evidence trail is kept in the sci-ATAC-seq research note. This note records the sci-ATAC-seq3-specific reading behind the schematic.

Sources read (bounded pass, 2026-10-17)

All three originals are in the shared family bundle $CHEM_DATA/sources/sci-atac-seq-family__10.1126+science.aab1601/.

Oligos (Table S7, verbatim)

No 5′ phosphate is printed on the N5/N7 ligation oligos; ligation joins their 3′ end to the Tn5-transferred 5′ end after T4 PNK phosphorylation. 🟡

How they interlock (computed in tools/sci3_graph.py)

Steps (article lines 209; protocols.io steps 5–13)

  1. Tagment fixed nuclei with Nextera v2 enzyme (2.5 µl/well, 55 °C 30 min); stop with EDTA/spermidine, 37 °C 15 min; pool and wash. 🟢
  2. T4 PNK with 1 mM rATP, 37 °C 30 min, nuclei aliquoted into four 96-well plates. 🟢
  3. N5 ligation: T7 ligase buffer, N5 splint and T7 DNA ligase added to the PNK reaction, then one of 384 N5 oligos per well; 25 °C 1 h; EDTA/spermidine stop; pool and wash. 🟢
  4. N7 ligation: master mix with N7 splint and T7 DNA ligase, 384 N7 oligos, 25 °C 1 h; stop; pool. 🟢
  5. Resuspend in EB, dilute to 1,000–3,000 nuclei per well (four 96-well plates); reverse cross-links with EB/Proteinase K/1% SDS, 65 °C 16 h. 🟢
  6. Test PCR with SYBR to set the cycle number; then NEBNext High-Fidelity 2X master mix, BSA, indexed P5 (column) and P7 (row) primers: 72 °C 5 min, 98 °C 30 s, 10–20 × (98 °C 10 s, 63 °C 30 s, 72 °C 1 min). 🟢 The initial 72 °C step is modelled as gap fill-in. 🟡
  7. Pool, Zymo Clean & Concentrator-5, then 1X AMPure; TapeStation; 2 nM pool. 🟢

Read layout

Article line 209 (NovaSeq 6000, custom recipe and Table S7 primers): Read 1 51, Read 2 51, Index 1 10 + 15 dark + 10, Index 2 10 + 15 dark + 10 cycles. 🟢 The protocols.io NextSeq QC recipe (3LV2_sciATAC_high, step 13) lists 50/50 genomic bases and the same 10 + 15 dark + 10 index structure; this is a separate QC instrument recipe, not a conflict with the NovaSeq production runs. The page uses the article values.

Open questions