Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
Modelled: The TSS-end molecule carries only the printed TSS tag; UMI and cell barcode are drawn on the TES end only. Evidence: All statements are in the published article and its rendered Fig. 1a. Remaining uncertainty: The full TSO sequence (Smart-seq2 ref 21) is not printed, and the article does not say how a TSO-end UMI or cell identifier would be read.
RT primer — 5′-AAGCAGTGGTATCAACGCAGAGTN₈[16 bps of cell barcode]T₃₀VN-3′ (Methods)
P5 index primer — 5′-AATGATACGGCGACCACCGAGATCTACAC[8 bps of index]TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGGTGGTATCAACGCAGAGT-3′ (Methods)
P7 index primer — 5′-CAAGCAGAAGACGGCATACGAGAT[8 bps of index]GTCTCGTGGGCTCGG-3′ (Methods)
TSS read tag — 5′-GTGGTATCAACGCAGAGTACATGGG-3′, of which GTGGTATCAACGCAGAGTACAT is trimmed as TSO sequence (read processing; the full TSO is not printed)
removed by the unspecified purification
Molecular structure is not represented in this graph.
Derived candidate: no capture-tag site for the P5 index primer, so not exponentially amplified; the 200–300 bp selection is the only separation described.
Molecular structure is not represented in this graph.
removed with the bead supernatant
Molecular structure is not represented in this graph.
left outside the collected size window
Molecular structure is not represented in this graph.
lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
| Read | Primer | Sequence | Lands on | First bases read |
|---|---|---|---|---|
| Read 1 | Nextera Read 1 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-3' | anneals to the bottom strand over S5, ME (P5 primer) | GTGGTATCAACG… (from capture tag) |
| Index 1 (i7) | Nextera Index 1 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-CTGTCTCTTATACACATCTCCGAGCCCACGAGAC-3' | anneals to the bottom strand over ME′ (Nextera XT, inferred), S7′ | IIIIIIIIATCT… (from i7) |
| Index 2 (i5) | Nextera Index 2, reverse-complement workflow Illumina "Indexed Sequencing Overview Guide" #15057455 | 5'-CTGTCTCTTATACACATCTGACGCTGCCGACGA-3'Forward-strand instruments prime i5 off the flow-cell P5 oligo instead. | anneals to the top strand over S5, ME (P5 primer) | jjjjjjjjGTGT… (from i5) |
| Read 2 | Nextera Read 2 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAG-3' | anneals to the top strand over ME′ (Nextera XT, inferred), S7′ | xxxxxxxxxxxx… (from transcript 3′ end (antisense)) |
| Read | Cycles | Content | Include in sequence analysis? |
|---|---|---|---|
| Read 1 | 150 | capture tag (cycles 1–18); UMI (cycles 19–26); cell barcode (cycles 27–42); oligo(dT) (cycles 43–72); VN (from cycle 73; molecule-dependent length); short molecules may read through into the opposite library end | Yes — after extracting identifiers |
| Index 1 (i7) | not fixed | sample index (cycles 1–8) | No — use for sample demultiplexing |
| Index 2 (i5) | not fixed | sample index (cycles 1–8) | No — use for sample demultiplexing |
| Read 2 | 150 | transcript 3′ end (antisense) (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end | Yes — include in sequence analysis |
lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
| Read | Primer | Sequence | Lands on | First bases read |
|---|---|---|---|---|
| Read 1 | Nextera Read 1 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAG-3' | anneals to the bottom strand over S5, ME (P5 primer) | GTGGTATCAACG… (from capture tag) |
| Index 1 (i7) | Nextera Index 1 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-CTGTCTCTTATACACATCTCCGAGCCCACGAGAC-3' | anneals to the bottom strand over ME′ (Nextera XT, inferred), S7′ | IIIIIIIIATCT… (from i7) |
| Index 2 (i5) | Nextera Index 2, reverse-complement workflow Illumina "Indexed Sequencing Overview Guide" #15057455 | 5'-CTGTCTCTTATACACATCTGACGCTGCCGACGA-3'Forward-strand instruments prime i5 off the flow-cell P5 oligo instead. | anneals to the top strand over S5, ME (P5 primer) | jjjjjjjjGTGT… (from i5) |
| Read 2 | Nextera Read 2 Illumina "Illumina Adapter Sequences" #1000000002694 | 5'-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAG-3' | anneals to the top strand over ME′ (Nextera XT, inferred), S7′ | xxxxxxxxxxxx… (from transcript 5′ end (sense)) |
| Read | Cycles | Content | Include in sequence analysis? |
|---|---|---|---|
| Read 1 | not fixed | capture tag (cycles 1–18); TSO ACAT (cycles 19–22); GGG (cycles 23–25); transcript 5′ end (sense) (from cycle 26; molecule-dependent length); short molecules may read through into the opposite library end | Yes — include in sequence analysis |
| Index 1 (i7) | not fixed | sample index (cycles 1–8) | No — use for sample demultiplexing |
| Index 2 (i5) | not fixed | sample index (cycles 1–8) | No — use for sample demultiplexing |
| Read 2 | not fixed | transcript 5′ end (sense) (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library end | Yes — include in sequence analysis |