Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
A lawn of randomly positioned 10-µm beads captures tissue mRNA. Each bead carries a 15-base split-pool barcode that is decoded in situ, an 8-base UMI and oligo-dT; template switching plus second-strand synthesis increases recovery before Nextera library preparation.
The Methods print Chemgenes and two custom bead-oligo versions. This schematic represents the Chemgenes J8–bridge–J7–UMI–oligo-dT core; the full bead oligos are listed below. The final duplex is the source-defined mixed endpoint (Truseq5 P5/TruSeq Read 1 arm on the bead end, Nextera XT mosaic end with an N7xx index on the tagmented end) with a variable transcript insert, so it is not a literal transcription of one sequenced molecule.
Custom bead version 2 barcode length.
Online Methods 'Barcoded beads', JATS text line 105 (vs2 oligo): JJJJJJJJ…JJJJJJ: 8 + 6 split-pool J bases, then 7 N and VV before T30
Online Methods 'Bead synthesis', JATS text line 111: split-pool procedure repeated 15 times (two blocks of 8 and 7 cycles)
Modelled: Model only the Chemgenes oligo (J8 + J7); vs1/vs2 are listed as printed. Evidence: Both passages were read in the PMC author-manuscript JATS; the Chemgenes and vs1 oligos print 8 + 7 J. Remaining uncertainty: Whether vs2 has 14 split-pool bases or the printed oligo omits one J is unresolved; the publisher PDF was not available for rendered comparison.
Truseq P5 (Truseq5) library primer — 5′-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATCT-3′ (with Nextera XT N700 index primers)
Reaction workflow
Slide-seqV2 library
Decode bead barcodes by 8 five-prime, 3 three-prime and 3 SEDAL ligations, formamide-stripping between primers. Inputs: TruSeq/UP hybridization primer series and 5(base)/3(base) fluorescent ligation oligos (Supplementary Table 6); T4 DNA ligase
Hybridize tissue mRNA to spatially decoded bead oligo-dT. Inputs: polyadenylated RNA from the 10-µm tissue section; 6× SSC, 2 U/µl RNase inhibitor, 30 min room temperature
Copy bead-captured tissue RNA from the bead oligo-dT. Inputs: bead-tethered barcode–UMI–oligo-dT capture oligo (RT primer); Maxima H− RT in Maxima RT buffer, dNTPs, RNase inhibitor; 1.5 h at 52 °C
Install the distal SMART handle in the same RT reaction. Inputs: Slide-seqV2 template-switch oligo AAGCAGTGGTATCAACGCAGAGTGAATrG+GrG (50 µM, 10 µl in 200 µl RT); Maxima H− RT in Maxima RT buffer, dNTPs, RNase inhibitor; 1.5 h at 52 °C
Digest the tissue in the RT mixture. Inputs: 2× tissue digestion buffer (SDS, EDTA, proteinase K), 37 °C 30 min
Release beads and wash by centrifugation. Inputs: beads pipetted off, glass discarded; three wash-buffer spins at 3000 RCF. Other outputs: glass substrate, digested tissue and RT reagents → discard
Treat beads with Exonuclease I. Inputs: Exonuclease I (NEB M0568) in ExoI buffer, 37 °C 50 min, then three washes. Other outputs: ExoI digestion products and washes → discard
Denature with NaOH and wash. Inputs: 0.1 N NaOH, 5 min room temperature; quenched with wash buffer, three washes. Other outputs: released RNA template and non-covalently paired strands → discard
Randomly prime and extend the bead-bound second strand. Inputs: dN-SMRT second-strand oligo AAGCAGTGGTATCAACGCAGAGTGANNNGGNNNB (2 µl of 1 mM in 200 µl); Klenow fragment (NEB M0210) in Maxima RT buffer with dNTPs, 37 °C 1 h, then three washes
Amplify spatial cDNA on beads. Inputs: TruSeq PCR handle CTACACGACGCTCTTCCGATCT; SMART PCR primer AAGCAGTGGTATCAACGCAGAGT; Terra PCR Direct polymerase mix (Takara 639270); 95 °C 3 min, 4 cycles (65 °C anneal), 9 cycles (67 °C anneal), 72 °C 5 min
Purify amplified cDNA twice with 0.6× AMPure XP. Inputs: AMPure XP 30 µl per 50 µl PCR (0.6×), performed twice; final 10 µl. Other outputs: 0.6× AMPure supernatants and washes → discard
Tagment 600 pg amplified cDNA (Nextera XT, manufacturer's instructions). Inputs: Nextera XT tagmentation reagent (FC-131-1096); Tn5 transposase (in Nextera XT). Other outputs: internal and SMART-end fragments without the bead TruSeq handle → discard
Amplify with Truseq P5 and an N7xx index primer. Inputs: Truseq P5 primer AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATCT; Nextera XT N700-series i7 index primer; Nextera XT PCR mix; 72 °C 3 min, 95 °C 30 s, 12 cycles (95/55/72 °C), 72 °C 5 min
Purify the library with 0.6× AMPure XP. Inputs: AMPure XP 0.6× (30 µl to 50 µl); 10 µl water. Other outputs: 0.6× AMPure supernatant, primers and washes → discard
Other material outcomes
glass substrate, digested tissue and RT reagents — discard
glass discarded and supernatants removed
Molecular structure is not represented in this graph.
ExoI digestion products and washes — discard
removed in the three post-ExoI wash spins
Molecular structure is not represented in this graph.
released RNA template and non-covalently paired strands — discard
removed with the quench and wash supernatants
Molecular structure is not represented in this graph.
0.6× AMPure supernatants and washes — discard
removed with the bead supernatants
Molecular structure is not represented in this graph.
internal and SMART-end fragments without the bead TruSeq handle — discard
not exponentially amplified by Truseq P5 + N7xx; carried into the 0.6× AMPure cleanup rather than physically separated by sequence
Molecular structure is not represented in this graph.
0.6× AMPure supernatant, primers and washes — discard
removed with the bead supernatant
Molecular structure is not represented in this graph.
Final Slide-seqV2 library
TruSeq Read 1 (42 cycles) reads the bead barcode blocks, constant and UMI; Nextera Read 2 (50 cycles) enters transcript sequence from the tagmented end; i7 (8 cycles) reads the N7xx sample index.
Sequencing primers
The final duplex shows the Illumina primer sites used to read bead identity and transcript sequence.
Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.
anneals to the top strand over Nextera mosaic end reverse complement, S7 reverse complement
xxxxxxxxxxxx… (from captured cDNA)
Read content and handling
Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.