smol-seq

Defining paper: Tan JH, Fraser AG. Quantifying metabolites using structure-switching aptamers coupled to DNA sequencing. Nature Biotechnology 44 (2026), doi:10.1038/s41587-025-02554-7. Read from the PMC Cloud open-access JATS (PMC12807852, s41587-025-02554-7_PMC12807852.xml.txt) and the published Supplementary Data 1 (…MOESM2_ESM.xlsx.txt, sheet SuppData1 Oligonucleotides). The MOESM1 PDF is the three-page Nature Portfolio reporting summary.

Sections read (2026-10-17 bounded pass)

Molecular design

🟢 Each structure-switching aptamer (SSA) is two oligos: a longer ligand-binding oligo (LBO), base-paired to a short release oligo (SRO) through a short stem. Cognate ligand drives the LBO into a stable stem-loop, which displaces and releases the SRO. The LBO is immobilized on a solid matrix, so ligand binding releases the SRO from the matrix (line 32). Each barcode SSA (bSSA) has an SRO with a barcode unique to its target.

🟢 Mefloquine LBO (Supplementary Data 1): /5Biosg/ATACCGCTCTCGGGACGACGGCAGTCTATACCCCGTATCGCCGAAGGTTGTCGTCCC. Mefloquine barcode 1 SRO: CGTCGTCCCGAGAGTAGC AGTCTGAC N5-7 AGATCGGAAGAGCGTCGTGTAG. Barcodes 2 and 3 are CTGATGCA and CGATCATG; ATP and piperaquine bSSAs follow the same SRO pattern with their own stems and three barcodes each.

🟢 SRO design (Methods line 81–83): 5′ stem-specific sequence – 8-nt barcode – N5–7 – AGATCGGAAGAGCGTCGTGTAG 3′; the 3′ end is a PCR handle "complementary to the Illumina P5 adaptor sequence" and the N5–7 random bases help sequence these low-diversity amplicons. They are not described as molecular identifiers.

🟡 Computed with chemdraw.Scene in the model: the MQ SRO's 5′ 14 nt pair with LBO bases 7–20 (chem.LBO_PAIRED, checked by sensor_scene()); the SRO's TAGC, barcode, N5–7 and handle are single-stranded. The LBO 3′ end (…GTCGTCCC) can also pair with that LBO stem region, consistent with the described ligand-stabilized stem-loop displacing the SRO; the fold itself is not drawn.

Step by step (Methods lines 65, 85–87)

  1. 🟢 25 pmol LBO + 125 pmol SRO heated to 95 °C for 5 min, slowly cooled to 25 °C.
  2. 🟢 Bound to 5 µL Dynabeads MyOne Streptavidin C1 for 30 min; washed twice, incubated 45 min, washed once.
  3. 🟢 In the sequenced experiment, ATP, PQ and MQ bSSAs (three barcodes each) were mixed and incubated 45 min with 125 µM ATP, 30 µM MQ, 25 µM PQ or PBS; the supernatant is the "released" sample.
  4. 🟢 The remaining bound SROs were boiled off (ligand-binding assay: Mg-free strand separation buffer, 95 °C 4 min) to give the "boiled" sample used to compute percentage release. The retained fraction is therefore sequenced, not discarded.
  5. 🟢 Replicates (marked by a short identifier sequence) were pooled, spike-in controls (ten sequences, twofold titration) added, and the single-stranded DNA purified with the Monarch kit oligonucleotide protocol.
  6. 🟢 Round-1 PCR adds partial P5/P7 handles (14 cycles released, 11 cycles boiled), primers ACACTCTTTCCCTACACGACGCTCTTCCGATC (Reverse P5) and GTGACTGGAGTTCAGACGTGTGCTCTTCCGATCT + stem (e.g. Forward MQ …CGTCGTCCCGAGAGTAGC). Monarch PCR cleanup, 20 µL elution, 1:5 dilution.
  7. 🟢 Round-2 PCR (5 µL template, 100 µL, 8 cycles) with AATGATACGGCGACCACCGAGATCTACAC [i5 index] ACACTCTTTCCCTACACGACG and CAAGCAGAAGACGGCATACGAGAT [i7 index] GTGACTGGAGTTCAGACGTG; Monarch cleanup; NucleoMag NGS size selection at 1.2× bead:sample.
  8. 🟢 MiSeq, ~4 million 50-bp single-end reads.

The model checks that both round-2 primer 3′ ends land on the round-1 product.

Final library and read

🟡 Derived: P5 – i5 – ACACTCTTTCCCTACACGACGCTCTTCCGATCT – N5–7′ – barcode′ – stem′ – AGATCGGAAGAGCACACGTCTGAACTCCAGTCAC – i7′ – P7′. The Read 1 site is assembled from the Reverse P5 primer plus the first templated T; Read 1 therefore reads the diversity bases, then the 8-nt analyte barcode (reverse complement), then the stem. The paper does not name the sequencing primers or index-read cycles: the TruSeq Read 1 primer is inferred, and the 8-nt i5/i7 windows are drawn as inferred placeholders.

Model corrections (2026-10-17)

The earlier generic schematic described a quenched capture strand, a separate "reporter-release condition", a single PCR and discarded unbound sensor. It now draws the published LBO/SRO pair on streptavidin beads, ligand-driven release, the sequenced boiled-off remainder, both PCR rounds with source primers, cleanups and the 50-bp single-end read.

Open questions