snapTotal-seq — source intake

Defining paper: Niu, Luo & Zong, "Single-cell total-RNA profiling unveils regulatory hubs of transcription factors", Nature Communications 15:5941 (2024), DOI 10.1038/s41467-024-50291-3; read as the PMC11251146 JATS/PDF with the publisher supplements. The bioRxiv preprint (10.1101/2023.12.14.571592) is superseded and not used for active claims.

Sources read (2026-10-17 bounded pass): JATS Methods "Cell lysis, reverse transcription, and amplification by snapTotal-seq" and "Sequencing library construction" (text lines 246–270 of the .xml.txt twin), and Supplementary Data 12 (MOESM15 workbook, sheet Table S12). Supplementary Fig. 1/2 (MOESM1) were not inspected in this pass.

Workflow (Methods)

  1. 🟢 Sorted single cells are lysed (42 °C, 3.5 min) in a buffer containing the primer mix (1.5 µM GAT27-N5-T12, 5 µM GAT27-N5-T3, 5 µM GAT27-N5-G3).
  2. 🟢 Maxima H Minus RT runs 10 cycles of 8/15/20/30/42/50 °C followed by 50 °C 15 min; template switching uses the existing MALBAC primers as template-switching oligos (Results). RT is inactivated at 74 °C for 25 min.
  3. 🟢 GoTaq Flexi PCR with GAT27, 23–26 cycles; 1.2X AMPure XP.
  4. 🟢 Per-cell double-strand conversion (DSC) with the cell barcode primer, Deep Vent (exo-), 15 cycles 63/72 °C, EDTA stop. The authors add the barcode after PCR so that it lands on one cDNA end only.
  5. 🟢 Pool 4 µL per cell, 1.1X AMPure, sonicate ~350 ng to 150–250 bp (Covaris S220), 1.8X AMPure.
  6. 🟢 Second DSC with Adapter-DSC (6 cycles 56/72 °C) "to enrich the DNA fragments with UMI and cell barcode"; 1.4X AMPure. 🟡 This is a primer-extension step, not a physical separation: untagged fragments are carried along and fall behind only in later PCRs.
  7. 🟢 dA tailing with Klenow (3′→5′ exo-) and dATP, RT 30 min; 1.4X AMPure. No separate end-repair step is described (the earlier page drew one; removed).
  8. 🟢 Quick Ligase Y-adapter ligation, RT 20 min, EDTA, 1.2X AMPure.
  9. 🟢 PCR with Adapter-PCR + Illumina-P5, 10 cycles; 1.2X AMPure.
  10. 🟢 DSN treatment (Evrogen) "to remove ribosomal reads": 100 ng, 95 °C 30 s, 80 °C 3 h, DSN 80 °C 15 min, EDTA; 1.2X AMPure.
  11. 🟢 Enrichment PCR with Adapter-DSC + Illumina-P5, 5 cycles; 1.2X AMPure.
  12. 🟢 Final PCR, 5 cycles: Adapter-P7 + Illumina-P5 (custom sequencing), or Truseq-P7

    • Illumina-P5 (standard Illumina sequencing, 55 °C anneal).

Published oligos (Supplementary Data 12, verbatim, spaces removed)

GAT27-5N-3G: GTGAGTGATGGTTGAGGATGTGTGGAGNNNNNGGG, GAT27-5N-3T: GTGAGTGATGGTTGAGGATGTGTGGAGNNNNNTTT, GAT27-5N-dT: GTGAGTGATGGTTGAGGATGTGTGGAGNNNNNTTTTTTTTTTTT 🟢 (NNNNN: UMI).

Final library and reads

🟡 The Y adapter ligates to both ends of every dA-tailed fragment; Adapter-PCR anneals inside the Adapter-DSC handle, so the amplified molecule runs P5–i5–Read 1–insert–UMI– spacer–cell barcode–handle. In the standard option, Truseq-P7 anneals to the cell-barcode primer's 5′ GTGTGCTCTTCCGATCT, so the TruSeq Read 2 primer reads the 8-nt cell barcode, the 35-nt primer-derived spacer and the 5-nt UMI. 🟢 This matches the Methods: "Read 2 sequenced the cell barcode (bases 1–8) and UMI (bases 44–48)". The earlier model placed the UMI next to the Read 2 primer; corrected.

🟢 In the custom run (NextSeq 500), Read 1 reads the captured RNA and Read 2 reads the UMI; the analysis takes the UMI as the first five bases of Read 2.

Open questions