snHi-C
1. What it is
Flyamer et al.'s single-nucleus Hi-C workflow, designed around whole-genome amplification rather than biotin-junction capture.
2. Sources and evidence
- ๐ข Flyamer et al., Nature 2017, DOI 10.1038/nature21711; author manuscript is available as PMC5639698.
- ๐ข The method isolates nuclei before fixation, digests with DpnII, performs proximity ligation without biotin enrichment, and uses phi29 multiple-displacement amplification.
- ๐ก The outer Illumina library shell is reconstructed because exact kit oligos are not printed.
- ๐ข The Supplementary Information (
nature21711_supp_NIHMS852755-supplement-supp_info.pdf.txt) says the embryonic/zygote branch sends sonicated MDA DNA to a sequencing service for library preparation without naming its adapter or PCR oligos. Its separate K562 branch describes an indexed Illumina adapter and Illumina primers after end repair and dA attachment, but likewise prints no sequences. These branch descriptions cannot establish that one adapter set was shared by both.
3. Distinguishing chemistry
There is no biotin fill or streptavidin bottleneck. All purified ligation products enter MDA, so the schematic keeps contact formation and the later sequencing-library conversion as separate transformations.
Bounded primary-source check (2026-10-16)
Inspected: Original PMC5639698 JATS title/abstract; original NIHMS852755 supp_info PDF text18โ68.
Selected isolated-pronucleus branch; separated whole-zygote branch. Added decrosslinking condition within MDA workflow without inventing internal order, post-MDA cleanup, sonication, second cleanup and paired 125-base reads. Library boundary names VBCF preparation and 300โ1300 bp selection; withdrew unverified absence claims.
Deferred: Cited GenomiPhi method31, manufacturer manual and VBCF detailed preparation; exact adapter assignment. This is a capped check, not a full source audit or confirmation of missing information.