Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. Candidate-specific comparison: inDrop hydrogel-bead droplet transcript barcoding retained in sorting/picoinjection workflow; fluorescence sorting and reagent staging are changed. Confidence is explicitly supported.
Fluorescence sorting enriches occupied inDrop-v3 droplets before a second device picoinjects reverse-transcription reagent.
The downstream inDrop library preparation remains summarized; IVT, adapter construction and recovery intermediates have not been mapped here. The RT primer is UV-released from the bead before picoinjection; it is not supplied by the RT mix.
Reaction workflow
spinDrop inDrop-v3 sequencing library
Co-encapsulate and fluorescence-sort droplets. Inputs: occupied/viable/target fluorescence gates. Other outputs: empty, damaged or unwanted droplets → discard
Lyse for 25 min at 23°C, then UV-release barcode primers (7 min). Inputs: 7-minute UV exposure after 25-minute room-temperature lysis
Picoinject RT solution into lysate droplets at 1:1 flow ratio. Inputs: picoinjected 1.8X First Strand Buffer, MgCl2, DTT and RNaseOUT
Reverse-transcribe 2 h at 50 °C, then 70 °C 15 min. Inputs: UV-released inDrop-v3 bead primer already present in the droplets; SuperScript III, 24 U/µL in injected solution
Other material outcomes
empty, damaged or unwanted droplets — discard
fails the inline fluorescence selection gates
Molecular structure is not represented in this graph.
Final sequencing library
The inDrop-v3 barcode read identifies cell and molecule; the insert read reports the transcript 3′ end.
Sequencing entry
The inDrop-v3 barcode read identifies cell and molecule; the insert read reports the transcript 3′ end.
Sequencing limitation. Published NextSeq profile: R1 61, I1 8, I2 8, R2 14 cycles. The v3 primer and identifier architecture has not been declared here; acquired index cycles do not establish index-region lengths.
Sequencing-primer binding on the final library
Read content and handling
Exact read placement is unresolved: The source-stated 61/8/8/14 acquired cycles are retained; the implementation-specific inDrop-v3 primers and identifier geometry remain unassigned in this model.
Read
Cycles
Content
Include in sequence analysis?
Read 1
61
cell barcode, UMI, sample index, inDrop-v3 library end; not yet declared, 3-prime transcript insert, inDrop-v3 opposite library end; not yet declared (read orientation and cycle boundaries unresolved)
Yes — after extracting identifiers
Index 1 (i7)
8
cell barcode, UMI, sample index, inDrop-v3 library end; not yet declared, 3-prime transcript insert, inDrop-v3 opposite library end; not yet declared (read orientation and cycle boundaries unresolved)
Yes — after extracting identifiers
Index 2 (i5)
8
cell barcode, UMI, sample index, inDrop-v3 library end; not yet declared, 3-prime transcript insert, inDrop-v3 opposite library end; not yet declared (read orientation and cycle boundaries unresolved)
Yes — after extracting identifiers
Read 2
14
cell barcode, UMI, sample index, inDrop-v3 library end; not yet declared, 3-prime transcript insert, inDrop-v3 opposite library end; not yet declared (read orientation and cycle boundaries unresolved)