Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. Guessed earlier physical-end-tagging analogue: Physical DNA-end tagging followed by long-read telomere measurement; Yeast TeloTag uses poly(A)/oligo tagging, whereas Telo-seq uses human telomere-complementary ligation splints and distinct end handling. Chemistry analogy; not established ancestry.
Source discrepancy: Schmidt et al. Methods (JATS line 169) specify six phased telorette adapters, but Supplementary Table 7 (Supplementary Information PDF lines 1780–1796) labels both the third and fourth distinct sequences T3 and has no T4 row. The model retains all six printed sequences in table order, treating the fourth sequence as the fourth phase; the intended fourth label has not been confirmed by the authors. The AMII motor adapter and its ligation reagents follow the ONT SQK-NBD111 kit instructions, which the article does not reproduce; their terminal bases remain unresolved, as does whether the 6-nt 3′ extension of S1 (beyond the telorette-core complement) is the AMII-pairing region.
Present adapter and substrate ends. Telorette-to-C-strand junction: the native overhang phase is sample-dependent, so the source supplies six phased arms rather than one end geometry.
Anneal telorettes to the G-overhang and ligate to the C-strand (35 °C 16 h; 65 °C 10 min). Inputs: six /5Phos/ phased telorettes (Supplementary Table 7), pre-mixed equally to 1 µM; 20 µL; 10,000 U T4 DNA ligase (NEB M0202) in 1x rCutSmart + 0.4 mM ATP, 200 µL
Cut genomic DNA with EcoRV-HF (37 °C 30 min; 65 °C 20 min). Inputs: 80 U EcoRV-HF (NEB R3195)
dA-tail the blunt EcoRV ends (37 °C 30 min). Inputs: 45 U Klenow Fragment (3′→5′ exo−) (NEB E6053) in 1x NEBNext dA-tailing buffer, 250 µL as 5 × 50 µL
Purify with 1x AMPure XP; elute in 190 µL water (37 °C 15 min). Inputs: 1x v/v AMPure XP (Beckman Coulter A63881). Other outputs: AMPure XP supernatant and washes → discard
Anneal the S1 splint (50 °C 1 h). Inputs: S1 splint oligo (Supplementary Table 7), 100 nM, with 50 mM NaCl
Purify with 0.5x AMPure XP; elute in 30 µL water (37 °C 15 min). Inputs: 0.5x v/v AMPure XP. Other outputs: AMPure XP supernatant and washes → discard
Present adapter and substrate ends. The Telo-seq source identifies the ONT AMII motor adapter and the disclosed S1 recruitment splint, but ONT does not publish the motor adapter's terminal ligating bases in the cited protocol.
Ligate the AMII sequencing adapter via the S1 splint (SQK-NBD111 instructions). Inputs: AMII motor-loaded sequencing adapter (SQK-NBD111 kit instructions); SQK-NBD111 sequencing-adapter ligation reagents
Other material outcomes
AMPure XP supernatant and washes — discard
removed with the bead supernatant and washes
Molecular structure is not represented in this graph.
AMPure XP supernatant and washes — discard
removed with the bead supernatant and washes
Molecular structure is not represented in this graph.
Sequencing entry
Primer or motor entry is shown explicitly for the completed library.
Read content and handling
This protocol's source describes a platform-specific sequencing entry rather than an Illumina R1/I1/I2/R2 cycle layout.
Read
Cycles
Content
Include in sequence analysis?
Sequencing output
not fixed
telomere-side motor-loaded ONT adapter ---> C-rich strand read telomere-outward; no sequencing primer