TT-seq — transient transcriptome sequencing

Protocol relationships
guessed: Metabolic labeling/enrichment of nascent RNA before sequencing; nanoCOP retains long molecules and uses nanopore readout.guessed: 4-thiouridine pulse labeling and affinity enrichment of newly transcribed RNA; sf4sU adds size fractionation and different biochemical controls.guessed: 4-thiouridine metabolic incorporation into new RNA; SLAM recodes thiol-bearing bases by alkylation rather than physical nascent-RNA enrichment.guessed: 4-thiouridine metabolic pulse labeling and affinity selection of nascent transcripts; SNU changes isolation/handling and read interpretation.TT-seqTT-seqSLAM-seqSLAM-seqSNU-SeqSNU-Seqnano-COPnano-COPsf4sU-Seqsf4sU-Seq

Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.

No formal ancestor assigned in this review. HumanNETseq andRNA-IP suggestions profile transcription but do not identify the older4sU chemical-enrichment strategy. Actual metabolicRNA-labeling predecessors remain external-identity follow-up.

Explore relationships and sequence similarity

Research notes

Defining paper: Schwalb et al., Science (2016).

A five-minute 4-thiouridine pulse marks newly made RNA. Fragmenting RNA before thiol capture makes only the newly synthesized pieces recoverable for sequencing.

The paper names the NuGEN Ovation Human Blood RNA-seq kit but does not print its adapter oligos. The Illumina-compatible library below is therefore an inferred run geometry. The supplement delegates 4sU purification to Dölken et al. (2008), which specifies EZ-Link Biotin-HPDP, streptavidin capture and DTT release.

Reaction workflow

inferred single-index TT-seq library

cells during the five-minute pulse [cells during the five-minute pulse] Transcribe RNA during the five-minute 4sU pulse [4sU-labelled newly synthesized RNA] Fragment RNA before selection [fragmented 4sU-labelled RNA] Covalently biotinylate 4sU thiols [biotinylated 4sU-containing RNA pieces] Capture biotinylated RNA fragments [streptavidin-bound newly synthesized RNA fragments] Release captured RNA with DTT [released 4sU-labelled RNA fragments] Treat purified labelled RNA with Turbo DNase [DNase-treated labelled RNA fragments] Convert captured RNA to strand-specific cDNA [strand-specific cDNA from captured RNA] Install the commercial sequencing adapters [adapter-completed TT-seq cDNA] Amplify and index the captured cDNA library inferred single-index TT-seq library 5'- P5 · 25 bp · Tm 62.3 °CAATGATACGGCGACCACCGAGATCTRead 1 arm · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTstrand-specific cDNA from captured RNAXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXdA junction · 1 bpAIndex 1 / Read 2 arm · 33 bp · Tm 66.8 °CGATCGGAAGAGCACACGTCTGAACTCCAGTCACsix-base i7 index reverse complement · 6 bpIIIIIIP7 reverse complement · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' inferred single-index TT-seq library 3'- P5' · 25 bp · Tm 61.7 °CTTACTATGCCGCTGGTGGCTCTAGARead 1 arm' · 33 bp · Tm 67.3 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAstrand-specific cDNA from captured RNA'xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxdA junction' · 1 bpTIndex 1 / Read 2 arm' · 33 bp · Tm 66.6 °CCTAGCCTTCTCGTGTGCAGACTTGAGGTCAGTGsix-base i7 index reverse complement' · 6 bpiiiiiiP7 reverse complement' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5'
  1. Transcribe RNA during the five-minute 4sU pulse. Inputs: 4-thiouridine pulse label; cellular RNA polymerases
  2. Fragment RNA before selection. Inputs: BioRuptor fragmentation condition
  3. Covalently biotinylate 4sU thiols. Inputs: EZ-Link Biotin-HPDP
  4. Capture biotinylated RNA fragments. Inputs: streptavidin selection reagent. Other outputs: unlabelled RNA fragments → discard
  5. Release captured RNA with DTT. Inputs: DTT elution reagent
  6. Treat purified labelled RNA with Turbo DNase. Inputs: 2 U Turbo DNase. Other outputs: digested contaminating DNA → discard
  7. Convert captured RNA to strand-specific cDNA. Inputs: NuGEN strand-specific RT primer; NuGEN reverse transcriptase
  8. Install the commercial sequencing adapters. Inputs: NuGEN Illumina-compatible library adapter
  9. Amplify and index the captured cDNA library. Inputs: NuGEN PCR forward primer; NuGEN indexed PCR reverse primer; library PCR polymerase

Other material outcomes

unlabelled RNA fragments — discard

unlabelled RNA is removed by streptavidin washing

Molecular structure is not represented in this graph.

digested contaminating DNA — discard

digested DNA is not carried as library substrate; no separate cleanup is printed before the commercial kit

Molecular structure is not represented in this graph.

Final sequencing library

INFERRED — Illumina-compatible paired-end, six-base single-index geometry; the defining supplement reports paired 50-base reads plus a six-base barcode.
library 5'- P5 · 25 bp · Tm 62.3 °CAATGATACGGCGACCACCGAGATCTRead 1 arm · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTstrand-specific cDNA from captured RNAXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXdA junction · 1 bpAIndex 1 / Read 2 arm · 33 bp · Tm 66.8 °CGATCGGAAGAGCACACGTCTGAACTCCAGTCACsix-base i7 index reverse complement · 6 bpIIIIIIP7 reverse complement · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' library 3'- P5' · 25 bp · Tm 61.7 °CTTACTATGCCGCTGGTGGCTCTAGARead 1 arm' · 33 bp · Tm 67.3 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAstrand-specific cDNA from captured RNA'xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxdA junction' · 1 bpTIndex 1 / Read 2 arm' · 33 bp · Tm 66.6 °CCTAGCCTTCTCGTGTGCAGACTTGAGGTCAGTGsix-base i7 index reverse complement' · 6 bpiiiiiiP7 reverse complement' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5' P5 Read 1 arm strand-specific cDNA from captured RNA six-base i7 index reverse complement dA junction P7 reverse complement Index 1 / Read 2 arm ^ sample index

Sequencing primers

The inferred standard primer sites show how the named HiSeq run enters the captured cDNA. Adapter bases are not asserted as NuGEN kit disclosures.

Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.

Sequencing primers on the final library
Read 1 / TruSeq Read 1 5'- TruSeq Read 1 · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCT -3' Index 1 (i7) / TruSeq Index 1 5'- TruSeq Index 1 · 33 bp · Tm 66.8 °CGATCGGAAGAGCACACGTCTGAACTCCAGTCAC -3' final library 5'- P5 · 25 bp · Tm 62.3 °CAATGATACGGCGACCACCGAGATCTRead 1 arm · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTstrand-specific cDNA from captured RNAXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXdA junction · 1 bpAIndex 1 / Read 2 arm · 33 bp · Tm 66.8 °CGATCGGAAGAGCACACGTCTGAACTCCAGTCACsix-base i7 index reverse complement · 6 bpIIIIIIP7 reverse complement · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' 3'- P5 · 25 bp · Tm 62.3 °CTTACTATGCCGCTGGTGGCTCTAGARead 1 arm · 33 bp · Tm 66.9 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAstrand-specific cDNA from captured RNAxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxdA junction · 1 bpTIndex 1 / Read 2 arm · 33 bp · Tm 66.8 °CCTAGCCTTCTCGTGTGCAGACTTGAGGTCAGTGsix-base i7 index reverse complement · 6 bpiiiiiiP7 reverse complement · 24 bp · Tm 59.8 °CTAGAGCATACGGCAGAAGACGAAC -5' Read 2 / TruSeq Read 2 3'- TruSeq Read 2 · 34 bp · Tm 67.3 °CTCTAGCCTTCTCGTGTGCAGACTTGAGGTCAGTG -5' ^ sample index
ReadPrimerSequenceLands onFirst bases read
Read 1TruSeq Read 1
Illumina "Illumina Adapter Sequences" #1000000002694
5'-ACACTCTTTCCCTACACGACGCTCTTCCGATCT-3'anneals to the bottom strand over Read 1 armXXXXXXXXXXXX… (from strand-specific cDNA from captured RNA)
Index 1 (i7)TruSeq Index 1
Illumina "Illumina Adapter Sequences" #1000000002694
5'-GATCGGAAGAGCACACGTCTGAACTCCAGTCAC-3'anneals to the bottom strand over Index 1 / Read 2 armIIIIIIATCTCG… (from six-base i7 index reverse complement)
Read 2TruSeq Read 2
Illumina "Illumina Adapter Sequences" #1000000002694
5'-GTGACTGGAGTTCAGACGTGTGCTCTTCCGATCT-3'anneals to the top strand over dA junction, Index 1 / Read 2 armxxxxxxxxxxxx… (from strand-specific cDNA from captured RNA)

Read content and handling

Content and cycle positions are derived from the final construct, primer direction, molecular-feature annotations and declared run lengths. ‘No’ means the read is auxiliary or absent, not that its information is unimportant.

ReadCyclesContentInclude in sequence analysis?
Read 150strand-specific cDNA from captured RNA (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library endYes — include in sequence analysis
Index 1 (i7)6sample index (cycles 1–6)No — use for sample demultiplexing
Index 2 (i5)—not acquiredNo — not sequenced
Read 250strand-specific cDNA from captured RNA (from cycle 1; molecule-dependent length); short molecules may read through into the opposite library endYes — include in sequence analysis