TUC-seq — original thiouridine-to-cytidine conversion
Protocol relationships
No curated ancestry links yet. This does not establish independent origins.
No formal ancestor assigned in this review. A most-likely predecessor/chemistry analogue cannot be responsibly selected before verifying the child preparation from its defining original.
HEK293 cells are pulse-labelled with 4sU; total RNA is treated with OsO4 in ammonium chloride, which converts 4sU into native cytidine; random-hexamer cDNA is amplified with gene-specific barcoded primers for seven transcripts, and the gel-purified amplicon pool is sequenced to count U-to-C changes. This native-C product differs from the substituted cytidine analogue in TimeLapse chemistry.
Sources: the 2017 Supporting Information (metabolic labelling, RNA isolation, tRNA and amplicon methods, Supporting Fig. 1 and Table 4) and the PubMed abstract. The main article, whose Experimental Section the SI cites for the 4sU-to-C conversion, has not been read. Conversion conditions are therefore partial: Supporting Fig. 1 gives OsO4 450 µM in 180 mM ammonium chloride for synthetic oligoribonucleotides, and the amplicon section gives 3 h at room temperature for cellular RNA; pH, the cellular-RNA OsO4 concentration and the post-conversion purification are unassigned. The barcode overhangs on the gene-specific PCR primers are not printed, and library preparation and Illumina HiSeq sequencing were a GATC Biotech service with no adapter, index or read-length details; that step is a warned boundary. Published cross-reference discrepancy: the SI amplicon section (page 15) says the primer sequences "are listed in Supporting Table S1", but Supporting Table 1 lists T-to-C mutation frequencies and the amplicon primers are printed in Supporting Table 4 ("Amplicon Sequencing"). The model uses the Table 4 primers. The tRNA-Val stem-loop RT-PCR branch ends in cloning and Sanger sequencing of 40 clones and is not drawn. INFERRED — RNA classes distinguished by pulse-label incorporation and a possible unconverted labelled class express population possibilities, not physical fractions or quantitative conversion yields.
original TUC-seq barcoded amplicon library (service library preparation unassigned)
Metabolically label newly synthesized RNA. Inputs: 4-thiouridine 0.05 or 0.1 mM in DMEM, 1 h; doxycycline 1 µg/ml added after 30 min; cellular RNA polymerases
Isolate and DNase-treat total RNA. Inputs: TRIzol isolation, DNase I (NEB), phenol–chloroform extraction, 0.3 M NaAc precipitation
Convert 4sU to native cytidine with OsO4/NH4Cl. Inputs: OsO4 in ammonium chloride buffer, 3 h room temperature (Supporting Fig. 1: 450 µM OsO4, 180 mM NH4Cl for synthetic RNAs); pH and cellular-RNA concentration unassigned
Reverse-transcribe with random hexamers. Inputs: random hexamer primers; GoScript Reverse Transcriptase (Promega), after unspecified post-conversion purification
Amplify selected targets with barcoded gene-specific primers. Inputs: forward gene-specific primers (_fw) with sample barcode overhangs for CcnA2, CcnB1, CcnD1, CcnE1, p21/Cdkn1A, eGFP and PCNA (cores in Supporting Table 4; overhangs not printed); reverse gene-specific primers (_rv) with sample barcode overhangs (cores in Supporting Table 4; overhangs not printed); "standard PCR conditions" (polymerase and cycles not stated)
Gel-purify amplicons and pool equimolarly. Inputs: 2% agarose gel separation, gel purification and equimolar pooling. Other outputs: gel material outside the excised amplicon bands → discard
Other material outcomes
gel material outside the excised amplicon bands — discard
left in the agarose gel
Molecular structure is not represented in this graph.
Final sequencing library
Barcoded gene-specific amplicons as far as the SI describes them. The barcode overhangs, the service-provider library adapters, indices and loaded run primers are not printed.
Sequencing entry
SI: reads were demultiplexed by sample-specific forward and reverse barcodes (flexbar), aligned to amplicon references (bowtie2) and U-to-C positions called within 146 bases of the amplicon ends. Illumina HiSeq (GATC Biotech); read length not stated.
Sequencing-primer binding on the final library
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
unassigned
sample barcode then gene-specific amplicon with U-to-C conversions; exact run/read primer unassigned