Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
TFIIH-associated excision products receive two splinted DNA adapters. Sequential lesion-specific immunoprecipitation separates CPD and6-4 products; appropriate photolyase repairs the selected oligo before indexed KAPA PCR.
INFERRED — representative fragment-end and PCR-reference assemblies follow the printed oligos, with genomic sequence unassigned. Five random bases in each blocked splint are hybridization degeneracy, not UMIs. This graph follows NHF1/CS-B anti-CPD first, then anti-6-4 on flowthrough; XP-C reverses that order. Exact source-linked lesion-IP buffer recipe, sample index assignments and loaded run primers remain unreviewed. A nominal30mer or mean26nt is not a fixed insert-length constraint.
RPIn family: 5'- sixN=selected sample index CAAGCAGAAGACGGCATACGAGATNNNNNNGTGACTGGAGTTCCTTGGCACCCGAGAATTCCA -3'
Reaction workflow
recovered DNA
Lyse and separate chromatin pellet from soluble material. Inputs: bufferA,Dounce lysis,chromatin centrifugation. Other outputs: separated chromatin pellet → discard
Present adapter and substrate ends. Published Methods: A5F/A5R and A3F/A3R random5nt splinted end ligations, SpacerC3 blocks; two end-detail views of one captured oligomer.
INFERRED — ligate two end-specific splinted adapters. Inputs: preannealed5-end and3-end splinted DNA adapters; T4DNA ligaseHC,PEG8000,overnight16C
PCI extraction and ethanol precipitation. Inputs: PCI extraction and ethanol precipitation. Other outputs: removed purification fractions → discard
Capture CPD; retain flowthrough for6-4PP IP. Inputs: anti-CPD antibody; source-linked IP procedure. Other outputs: CPD-IP flowthrough for subsequent6-4PP capture
INFERRED — lesion-specific photorepair before PCR. Inputs: 20pmol Drosophila CPD photolyase; 366nm18mW/cm2,2h on ice,sourcePLR buffer
Reserve1% repaired material for QC. Inputs: 1% repaired sample for quality check. Other outputs: repaired sample QC aliquot → QC
PCI extraction/ethanol precipitation after photorepair. Inputs: PCI extraction/ethanol precipitation after photorepair. Other outputs: removed purification fractions → discard
PCI/ethanol;10%nativePAGE130–155nt band excision;NaCl elution/ethanol;PicoGreen. Inputs: PCI/ethanol;10%nativePAGE130–155nt band excision;NaCl elution/ethanol;PicoGreen. Other outputs: removed purification fractions → discard
recovered DNA
Lyse and separate chromatin pellet from soluble material. Inputs: bufferA,Dounce lysis,chromatin centrifugation. Other outputs: separated chromatin pellet → discard
Present adapter and substrate ends. Published Methods: A5F/A5R and A3F/A3R random5nt splinted end ligations, SpacerC3 blocks; two end-detail views of one captured oligomer.
INFERRED — ligate two end-specific splinted adapters. Inputs: preannealed5-end and3-end splinted DNA adapters; T4DNA ligaseHC,PEG8000,overnight16C
PCI extraction and ethanol precipitation. Inputs: PCI extraction and ethanol precipitation. Other outputs: removed purification fractions → discard
Capture CPD; retain flowthrough for6-4PP IP. Inputs: anti-CPD antibody; source-linked IP procedure. Other outputs: purified CPD-selected adapter-ligated DNA
Capture6-4PP from CPD-IP flowthrough. Inputs: anti-6-4PP antibody; source-linked IP procedure. Other outputs: material not selected by subsequent6-4PP capture → unresolved
INFERRED — lesion-specific photorepair before PCR. Inputs: 1.25pmol E.coli6-4PP photolyase; 366nm18mW/cm2,2h on ice,sourcePLR buffer
Reserve1% repaired material for QC. Inputs: 1% repaired sample for quality check. Other outputs: repaired sample QC aliquot → QC
PCI extraction/ethanol precipitation after photorepair. Inputs: PCI extraction/ethanol precipitation after photorepair. Other outputs: removed purification fractions → discard
Molecular structure is not represented in this graph.
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
material not selected by subsequent6-4PP capture — unresolved
Remaining unselected flowthrough is not a sequencing branch here; no physical disposal or complete depletion is asserted.
material not selected by subsequent6-4PP capture — unresolved
repaired sample QC aliquot — QC
Source allows unrepaired or repaired aliquotQC; graph represents repaired-aliquot choice.
repaired sample QC aliquot — QC
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
repaired sample QC aliquot — QC
Source allows unrepaired or repaired aliquotQC; graph represents repaired-aliquot choice.
repaired sample QC aliquot — QC
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
removed purification fractions — discard
Source recovery removes separated fractions; no perfect recovery asserted.
Molecular structure is not represented in this graph.
Final sequencing library
INFERRED — PCR reference derived from full source primers and retained template interval; source sample index member and genomic sequence remain unassigned.
Sequencing entry
Source collects1x50 reads; adapter-trimmed inserts report the repair-excised strand. Sequencing measures repair products rather than all genomic photolesions.
Sequencing-primer binding on the final library
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
50
excised repair oligonucleotide and possible flanking adapter read-through
Yes — include in sequence analysis
Index 1 (i7)
unassigned
six-base molecular index; selected member and acquired cycles unassigned