Motion between frames: brightness constancy and the aperture problem

Image analysis

About this lecture

FFT registration found one shift for a whole image. Cells crawl, tissues fold, cytoplasm streams: every part moves differently. Today: give every pixel its own motion vector.

  • A flow field and how to read it (arrows, the colour wheel).
  • Brightness constancy: a moving point keeps its grey value, and when biology breaks it.
  • 1D first: speed = −(change in time) / (slope), and why a window of pixels helps.
  • Kymographs: motion as the slope of a line in an x–t image.
  • The aperture problem: along an edge only the motion across the edge can be seen.

Slides titled The math give the formulas and proofs; the ideas are complete without them.

Recall: one shift for the whole image

FFT registration and stitching found the single translation that best aligns two images: one peak in the correlation surface.

That is the right model for stage drift or tiles of a mosaic. It is the wrong model when

  • a cell migrates while its neighbours stay put,
  • an embryo’s tissue converges in one place and spreads in another,
  • cytoplasm streams in a loop.

Now every pixel gets its own vector: where did the content of this pixel go between frame 1 and frame 2? That field of vectors is the optical flow.

Showing a flow field

  • Arrows on a coarse grid: length = speed. Easy to read, but only a few hundred fit.
  • Colour wheel: hue = direction (red = right, counter-clockwise round the wheel), saturation = speed, white = still. Every pixel shown.
  • Saturation is relative to the largest speed shown: always state the scale (“edge of the wheel = 2 px/frame”).

Try it: reading flow fields

Brightness constancy

The one assumption that links images to motion: a moving point keeps its grey value.

If the content at (x, y) in frame 1 moves by (u, v), then frame 2 at (x + u, y + v) shows the same value.

It holds when illumination is fixed, the sample stays in focus and the frame interval is short. It fails when

  • the dye bleaches (everything gets darker every frame),
  • fluorophores blink, or objects enter or leave the focal plane,
  • a 3D object rotates and its shading changes, or the illumination flickers.

Where it fails, every method of this day reports motion that is not there (or misses motion that is).

Top: a bright spot in frame 1 and the same spot 10 percent darker in frame 2, not moved. Bottom: the per-pixel speed minus I_t over I_x is about +0.5 pixels per frame on the left flank and about -0.5 on the right flank, although the true speed is zero.

1D first: a profile that moves

A profile moves right by u pixels per frame. At a pixel on a slope I_x, the value changes by I_t \approx -I_x\,u from frame 1 to frame 2, so u = -\,I_t / I_x .

  • On the slope: works. On a flat stretch (I_x = 0): no information. At the peak: none either.
  • Pixels disagree (0.5, undefined, 1.5 above). Combine a window by least squares: u = -\sum I_x I_t / \sum I_x^2 = 8.5/8.5 = 1, exactly right.

1D speed as pseudocode

for every pixel x of the window:
    Ix = (frame1(x+1) − frame1(x−1)) / 2      # slope
    It = frame2(x) − frame1(x)                 # change in time
    one pixel alone:  u = −It / Ix             # only where Ix is not 0
window:  u = − Σ Ix·It / Σ Ix²
  • One sum over the window replaces many unreliable divisions.
  • The sum in the denominator is 0 only if the whole window is flat: then there is no answer.

The math: the optical flow constraint

Brightness constancy: I(x + u\,\delta t,\; y + v\,\delta t,\; t + \delta t) = I(x, y, t).

First-order Taylor expansion of the left side: I + I_x u\,\delta t + I_y v\,\delta t + I_t\,\delta t + O(\delta t^2) = I \quad\Rightarrow\quad I_x u + I_y v + I_t = 0, i.e. \nabla I \cdot (u, v) = -I_t (with \delta t = one frame).

  • Valid while the motion is small compared with the distance over which the gradient changes (the neglected term involves the second derivatives times u^2). Large motion: the next unit.
  • In 1D: u = -I_t / I_x. Over a window, least squares minimises \sum (I_x u + I_t)^2; setting the derivative 2\sum I_x(I_x u + I_t) to zero gives u = -\sum I_x I_t / \sum I_x^2.

Kymographs: motion as a slope

Stack the profile of every frame under the previous one: an x–t image. A moving feature draws a line; its slope (pixels per frame) is its speed.

  • Steeper away from vertical = faster; vertical = still; crossing lines = features passing each other; a curved line = acceleration.
  • Biology: vesicles moving along an axon, a cell edge protruding and retracting.
  • 1D flow is the orientation of the lines in this image: the structure tensor measures it, now in x–t instead of x–y.

Try it: speed from slope and change

The aperture problem

In 2D, each pixel gives one equation for two unknowns (u, v).

Look at a straight edge through a small hole: you see it move across itself, never along itself. The motion along the edge changes nothing you can see.

  • What a single pixel (or a straight edge) can measure is the normal flow: the component of the motion along the gradient.
  • The barber pole: stripes seen through a tall slit seem to move up, whatever their true motion.
  • A corner or a texture has gradients in several directions: that resolves it.

A circular hole showing a dark and a bright half separated by a straight edge, with the edge one frame later dashed. Three different true motion arrows all end on the dashed edge; the thick normal flow arrow is perpendicular to the edge.

Constraint lines in velocity space

Draw velocity space, u across and v (down) up the page. Every velocity that would explain one pixel’s change lies on a line in this space.

  • An edge: all its pixels give the same line. The truth is somewhere on it; the point closest to the origin is the normal flow.
  • A corner: two families of lines cross at the true velocity.
  • A flat patch: no line at all.

The math: the constraint line

For one pixel, \{(u, v) : I_x u + I_y v = -I_t\} is a line with normal \nabla I.

  • Its distance from the origin is |I_t| / |\nabla I|; its closest point is the normal flow \mathbf u_\perp = -\,\frac{I_t}{|\nabla I|^2}\,\nabla I .
  • Two pixels: the 2\times2 system \begin{pmatrix} I_{x,1} & I_{y,1}\\ I_{x,2} & I_{y,2}\end{pmatrix}\begin{pmatrix}u\\v\end{pmatrix} = -\begin{pmatrix}I_{t,1}\\I_{t,2}\end{pmatrix} has a unique solution iff the determinant is not zero: iff the two gradients are not parallel.
  • Example: (I_x, I_y, I_t) = (1, 0, -2) and (0, 1, -1): the lines u = 2 and v = 1 meet at (2, 1).
  • The aperture problem is rank deficiency: all gradients parallel, rank 1.

Try it: the aperture

Where the next units go

One equation per pixel is not enough. Two ways to add information:

Lucas–Kanade (next unit) Horn–Schunck (unit after)
assumption flow is constant in a small window flow is smooth over the whole image
method least squares over the window’s lines data + λ·smoothness, solved iteratively
output a vector where the window has texture, plus a confidence a vector everywhere (fills in flat regions)

Both rely on brightness constancy and on small motion.

Summary

  • A flow field gives each pixel a vector: where its content went. Show it with arrows or the colour wheel (hue = direction, saturation = speed, scale stated).
  • Brightness constancy: a moving point keeps its grey value; bleaching, blinking, focus changes and shading break it.
  • In 1D, speed = −(change in time)/(slope); single pixels are unreliable, a window combined by least squares is not.
  • A kymograph turns motion into the slope of lines.
  • The aperture problem: an edge shows only the motion across it. Each pixel’s constraint is a line in velocity space; edges with different directions (corners, texture) make the lines cross at the true motion.