Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. Most likely earlier design precursor within the inspected method family. Biotin-nucleotide run-on and nascent-RNA sequence readout, performed from chromatin rather than standard nuclear run-on input.
Isolated chromatin retains engaged polymerases. ATP/GTP plus biotin-CTP/biotin-UTP support run-on, followed by RNA recovery, base hydrolysis, three streptavidin captures, two RNA-adapter ligations, reverse transcription and PCR. This graph shows the ChRO branch.
The cited PRO-seq protocol prints VRA3/VRA5 and RP1/RPI-n; those source oligos are listed as predecessor reagents. They are not assigned unchanged to every ChRO library. The article and Supplementary Table 1 identify sample-specific six-base UMI variants. Exact study oligo orders and run masks remain open model questions. The biotin run-on label is a chemical affinity label, not a barcode or an eight-base UMI.
Cited PRO-seq predecessor, RT/PCR primer RP1: 5′-AATGATACGGCGACCACCGAGATCTACACGTTCAGAGTTCTACAGTCCGA-3′
Cited PRO-seq predecessor, indexed PCR primer RPI-n: 5′-CAAGCAGAAGACGGCATACGAGATNNNNNNGTGACTGGAGTTCCTTGGCACCCGAGAATTCCA-3′
Reaction workflow
ChRO-seq sequencing library
Isolate and wash chromatin in NUN buffer. Inputs: NUN isolation and wash conditions with RNase inhibitor. Other outputs: isolation and wash supernatants → discard
Sonicate to suspend the chromatin pellet. Inputs: sonication in chromatin storage buffer
Extend already-engaged nascent transcripts. Inputs: already-engaged RNA polymerase; ATP, GTP, biotin-11-CTP and biotin-11-UTP; 2× chromatin run-on buffer (300 mM KCl, 1% Sarkosyl, SUPERase In), 37 °C 5 min
Stop run-on and recover RNA. Inputs: Trizol LS stop and GlycoBlue-assisted RNA recovery. Other outputs: run-on extraction removed fraction → discard
Fragment RNA by base hydrolysis (ChRO branch). Inputs: 65 °C 40 s heat denaturation, then 0.2 N NaOH on ice 8 min
Recover RNA from beads using Trizol. Inputs: Trizol RNA recovery. Other outputs: beads and extraction removed fraction → discard
Present adapter and substrate ends. Study-specific adapter variant and exact source end geometry remain under review; predecessor Table1 is not assigned unchanged.
Ligate the 3′ RNA adapter. Inputs: study 3′ RNA adapter (variant under review); T4 RNA ligase I, source M0204L
Purify RNA after RppH and PNK. Inputs: Trizol purification after 5′ end preparation. Other outputs: 5′ preparation purification removed fraction → discard
Present adapter and substrate ends. Study-specific 5′-adapter variant remains under review.
Ligate the 5′ RNA adapter. Inputs: study 5′ RNA adapter (variant under review); RNA ligase for inherited 5′-adapter step
Molecular structure is not represented in this graph.
unbound capture/wash fraction — discard
is removed during source streptavidin binding/washes
Molecular structure is not represented in this graph.
beads and extraction removed fraction — discard
is separated from recovered RNA during source bead release/extraction
Molecular structure is not represented in this graph.
ChRO and leChRO are different source branches. leChRO is length-extension ChRO: RNase cocktail replaces inhibitor during initial isolation and post-run-on hydrolysis is omitted. It is not a linear-amplification branch.
Final sequencing library
Role-level amplified ChRO library; exact study adapter arms, index architecture and primer sites are not selected.
Sample-specific six-base molecule identifiers. The article says first six sequenced bases only for marked libraries. Original Supplementary Table 1 marks UMU94-13_leChr, GBM-88-04_Chr and PDX-88-04_P57 among others. Blank aggregate/subsample cells are not a universal oligo assignment.
Sequencing entry
The source names NextSeq 500. For ChRO-seq, the nascent RNA 3′ end is represented by the 5′ end of the sequenced read; leChRO-seq instead represents the RNA 5′ end by the read 3′ end. The first six sequenced bases are a molecule identifier only for libraries marked in Supplementary Table 1; this does not set an instrument-wide run mask.
Read content and handling
Exact read placement is unresolved: the exact sequencing-primer site is not represented
Read
Cycles
Content
Include in sequence analysis?
Sequencing output
not fixed
Illumina-compatible left end, nascent-RNA-derived cDNA, Illumina-compatible right end (read orientation and cycle boundaries unresolved)