No curated ancestry links yet. This does not establish independent origins.
No formal ancestor assigned in this review. The inspected source does not establish a specific earlier protocol. Mechanistic similarity and shared endpoints alone do not justify selecting one, and this bounded pass does not establish independent invention.
Individual microbes are lysed and MDA-amplified in droplets, tagmented by reagent fusion, then fused with barcode-bead droplets for barcoding PCR.
INFERRED — preprint-derived model. The published Science article and supplement were not readable (publisher 403; the only open-access copy indexed for this DOI, OSTI purl 1959222, turns out to be the bioRxiv v1 preprint PDF); conditions, oligos and read configuration come from the linked bioRxiv v1 supplement and may differ in the published version. Table S6 prints the barcode-1 (8–11 nt, 96 oligos) and barcode-2 (8 nt, 384 oligos) extension oligos; the initiating hydrogel oligo, the P5PE1 primer and the custom Read-1 primer are not printed. The final library shows one 8-nt barcode-1 representative.
Reaction workflow
Microbe-seq library (preprint-derived)
Partition microbes into lysis droplets. Inputs: single-microbe droplet loading condition. Other outputs: empty or multiplet droplets → discard
Merge MDA-reagent droplets; amplify 30 °C 6–8 h, 65 °C 10 min. Inputs: MDA random primers; phi29 DNA polymerase (MDA reagent droplet merge)
Merge Nextera droplets and tagment, 55 °C 10 min. Inputs: Nextera tagmentation reagent (commercial); Tn5 transposase. Other outputs: fragments without an S5-adapter end → discard
Merge bead/PCR droplets: 72 °C 4 min gap fill, then 10 PCR cycles. Inputs: photocleavable hydrogel-bead primer: hydrogel oligo + barcode 1 + linker + barcode 2 + Tn5 arm; opposite (S7-side) droplet primer: presence and identity not printed; Phusion PCR reagents
Remove droplets that merged during PCR. Inputs: droplet size-filter device. Other outputs: enlarged post-PCR merged droplets (possible multi-microbe) → discard
Break the emulsion and purify the aqueous phase. Inputs: PFO emulsion breaking, 1.1× AMPure. Other outputs: oil phase and unretained small DNA → discard
Add P5 and the Nextera i7 sample index by PCR. Inputs: P5PE1 primer (IDT; bases not printed); Nextera i7 index primer (Illumina); Phusion HF polymerase, 5–10 cycles
Purify the library with 0.8× AMPure. Inputs: 0.8× AMPure. Other outputs: primers and short products below the 0.8× cutoff → discard
Other material outcomes
empty or multiplet droplets — discard
empty and multiplet droplets do not yield accepted single-microbe libraries
Molecular structure is not represented in this graph.
insoluble microbial debris — discard
insoluble debris does not contribute to the sequencing library
Molecular structure is not represented in this graph.
fragments without an S5-adapter end — discard
fragments lacking the S5-adapter end are not primed by the bead primer
Molecular structure is not represented in this graph.
the size-filter device removes most enlarged droplets
Molecular structure is not represented in this graph.
oil phase and unretained small DNA — discard
removed by phase separation and bead cleanup
Molecular structure is not represented in this graph.
primers and short products below the 0.8× cutoff — discard
not retained by 0.8× AMPure beads
Molecular structure is not represented in this graph.
Final sequencing library
INFERRED — preprint Table S6 arms. The bead primer carries barcode 1, a 22-nt linker and barcode 2 upstream of the Tn5 S5/mosaic-end arm; the Nextera i7 primer adds the single 8-nt sample index.
Sequencing entry
Preprint supplementary Methods: a custom Read-1 primer is required. In a 100-bp run, Read 1 is 45 bp of barcode only, Index 1 is 8 bp and Read 2 contains microbial sequence. In a 300-bp run, Read 1 is 150 bp (first 45 bp barcode, last 75 bp microbial, adapter between).
Sequencing limitation. A custom Read-1 primer (IDT) is required, but its sequence is not printed in the preprint; the Read-1 landing site is therefore not computed.
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
45
custom Read-1 primer: bead barcode 1, linker, barcode 2 (100-bp run; 150 in a 300-bp run)