Microbe-seq — droplet single-microbe genome sequencing

Protocol relationships

No curated ancestry links yet. This does not establish independent origins.

No formal ancestor assigned in this review. The inspected source does not establish a specific earlier protocol. Mechanistic similarity and shared endpoints alone do not justify selecting one, and this bounded pass does not establish independent invention.

Ancestry review is blocked on original sources.

Explore relationships and sequence similarity

Research notes

Defining source: Zheng et al., Science (2022).

Individual microbes are lysed and MDA-amplified in droplets, tagmented by reagent fusion, then fused with barcode-bead droplets for barcoding PCR.

INFERRED — preprint-derived model. The published Science article and supplement were not readable (publisher 403; the only open-access copy indexed for this DOI, OSTI purl 1959222, turns out to be the bioRxiv v1 preprint PDF); conditions, oligos and read configuration come from the linked bioRxiv v1 supplement and may differ in the published version. Table S6 prints the barcode-1 (8–11 nt, 96 oligos) and barcode-2 (8 nt, 384 oligos) extension oligos; the initiating hydrogel oligo, the P5PE1 primer and the custom Read-1 primer are not printed. The final library shows one 8-nt barcode-1 representative.

Reaction workflow

Microbe-seq library (preprint-derived)

microbial suspension [microbial suspension] Partition microbes into lysis droplets [droplets containing individual microbes] Lyse microbes inside droplets [lysed single-microbe genomic DNA] Merge MDA-reagent droplets; amplify 30 °C 6–8 h, 65 °C 10 min [single-microbe MDA products] Merge Nextera droplets and tagment, 55 °C 10 min [tagmented MDA fragments with 9-nt gaps] Merge bead/PCR droplets: 72 °C 4 min gap fill, then 10 PCR cycles [bead-barcoded genomic amplicons] Remove droplets that merged during PCR [size-filtered barcoded droplets] Break the emulsion and purify the aqueous phase [purified pooled barcoded amplicons] Add P5 and the Nextera i7 sample index by PCR [indexed library before cleanup] Purify the library with 0.8× AMPure Microbe-seq library (preprint-derived) 5'- P5PE1-derived end[P5PE1 primer: bases not printed]hydrogel-oligo arm · 30 bp · Tm 64.9 °CCTCTTTCCCTACACGACGCTCTTCCGATCTbarcode 1 (8–11 nt) · 8 bpBBBBBBBBbarcode linker · 22 bp · Tm 58.8 °CGAGTGATTGCTTGTGACGCCTTbarcode 2 · 8 bpBBBBBBBBbead Tn5-adapter arm · 30 bp · Tm 64.7 °CTCGTCGGCAGCGTCAGATGTGTATAAGAGAcopied mosaic-end bases · 3 bpCAGsingle-microbe genomic DNAXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXmosaic end (rc) · 19 bp · Tm 45.7 °CCTGTCTCTTATACACATCTNextera i7 primer arm (rc) · 15 bp · Tm 54.4 °CCCGAGCCCACGAGACi7 sample index · 8 bpIIIIIIIIP7 (rc) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' Microbe-seq library (preprint-derived) 3'- P5PE1-derived end'[P5PE1 primer: bases not printed]hydrogel-oligo arm' · 30 bp · Tm 65.3 °CGAGAAAGGGATGTGCTGCGAGAAGGCTAGAbarcode 1 (8–11 nt)' · 8 bpbbbbbbbbbarcode linker' · 22 bp · Tm 57.9 °CCTCACTAACGAACACTGCGGAAbarcode 2' · 8 bpbbbbbbbbbead Tn5-adapter arm' · 30 bp · Tm 64.9 °CAGCAGCCGTCGCAGTCTACACATATTCTCTcopied mosaic-end bases' · 3 bpGTCsingle-microbe genomic DNA'xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxmosaic end (rc)' · 19 bp · Tm 45.7 °CGACAGAGAATATGTGTAGANextera i7 primer arm (rc)' · 15 bp · Tm 54.8 °CGGCTCGGGTGCTCTGi7 sample index' · 8 bpiiiiiiiiP7 (rc)' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5'
  1. Partition microbes into lysis droplets. Inputs: single-microbe droplet loading condition. Other outputs: empty or multiplet droplets → discard
  2. Lyse microbes inside droplets. Inputs: droplet lysis reagents. Other outputs: insoluble microbial debris → discard
  3. Merge MDA-reagent droplets; amplify 30 °C 6–8 h, 65 °C 10 min. Inputs: MDA random primers; phi29 DNA polymerase (MDA reagent droplet merge)
  4. Merge Nextera droplets and tagment, 55 °C 10 min. Inputs: Nextera tagmentation reagent (commercial); Tn5 transposase. Other outputs: fragments without an S5-adapter end → discard
  5. Merge bead/PCR droplets: 72 °C 4 min gap fill, then 10 PCR cycles. Inputs: photocleavable hydrogel-bead primer: hydrogel oligo + barcode 1 + linker + barcode 2 + Tn5 arm; opposite (S7-side) droplet primer: presence and identity not printed; Phusion PCR reagents
  6. Remove droplets that merged during PCR. Inputs: droplet size-filter device. Other outputs: enlarged post-PCR merged droplets (possible multi-microbe) → discard
  7. Break the emulsion and purify the aqueous phase. Inputs: PFO emulsion breaking, 1.1× AMPure. Other outputs: oil phase and unretained small DNA → discard
  8. Add P5 and the Nextera i7 sample index by PCR. Inputs: P5PE1 primer (IDT; bases not printed); Nextera i7 index primer (Illumina); Phusion HF polymerase, 5–10 cycles
  9. Purify the library with 0.8× AMPure. Inputs: 0.8× AMPure. Other outputs: primers and short products below the 0.8× cutoff → discard

Other material outcomes

empty or multiplet droplets — discard

empty and multiplet droplets do not yield accepted single-microbe libraries

Molecular structure is not represented in this graph.

insoluble microbial debris — discard

insoluble debris does not contribute to the sequencing library

Molecular structure is not represented in this graph.

fragments without an S5-adapter end — discard

fragments lacking the S5-adapter end are not primed by the bead primer

Molecular structure is not represented in this graph.

enlarged post-PCR merged droplets (possible multi-microbe) — discard

the size-filter device removes most enlarged droplets

Molecular structure is not represented in this graph.

oil phase and unretained small DNA — discard

removed by phase separation and bead cleanup

Molecular structure is not represented in this graph.

primers and short products below the 0.8× cutoff — discard

not retained by 0.8× AMPure beads

Molecular structure is not represented in this graph.

Final sequencing library

INFERRED — preprint Table S6 arms. The bead primer carries barcode 1, a 22-nt linker and barcode 2 upstream of the Tn5 S5/mosaic-end arm; the Nextera i7 primer adds the single 8-nt sample index.
library 5'- P5PE1-derived end[P5PE1 primer: bases not printed]hydrogel-oligo arm · 30 bp · Tm 64.9 °CCTCTTTCCCTACACGACGCTCTTCCGATCTbarcode 1 (8–11 nt) · 8 bpBBBBBBBBbarcode linker · 22 bp · Tm 58.8 °CGAGTGATTGCTTGTGACGCCTTbarcode 2 · 8 bpBBBBBBBBbead Tn5-adapter arm · 30 bp · Tm 64.7 °CTCGTCGGCAGCGTCAGATGTGTATAAGAGAcopied mosaic-end bases · 3 bpCAGsingle-microbe genomic DNAXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXmosaic end (rc) · 19 bp · Tm 45.7 °CCTGTCTCTTATACACATCTNextera i7 primer arm (rc) · 15 bp · Tm 54.4 °CCCGAGCCCACGAGACi7 sample index · 8 bpIIIIIIIIP7 (rc) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' library 3'- P5PE1-derived end'[P5PE1 primer: bases not printed]hydrogel-oligo arm' · 30 bp · Tm 65.3 °CGAGAAAGGGATGTGCTGCGAGAAGGCTAGAbarcode 1 (8–11 nt)' · 8 bpbbbbbbbbbarcode linker' · 22 bp · Tm 57.9 °CCTCACTAACGAACACTGCGGAAbarcode 2' · 8 bpbbbbbbbbbead Tn5-adapter arm' · 30 bp · Tm 64.9 °CAGCAGCCGTCGCAGTCTACACATATTCTCTcopied mosaic-end bases' · 3 bpGTCsingle-microbe genomic DNA'xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxmosaic end (rc)' · 19 bp · Tm 45.7 °CGACAGAGAATATGTGTAGANextera i7 primer arm (rc)' · 15 bp · Tm 54.8 °CGGCTCGGGTGCTCTGi7 sample index' · 8 bpiiiiiiiiP7 (rc)' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5' P5PE1-derived end hydrogel-oligo arm barcode 1 (8–11 nt) barcode 2 copied mosaic-end bases mosaic end (rc) Nextera i7 primer arm (rc) barcode linker bead Tn5-adapter arm single-microbe genomic DNA i7 sample index P7 (rc) ^ cell barcode · bc1 ^ cell barcode · bc2 ^ sample index

Sequencing entry

Preprint supplementary Methods: a custom Read-1 primer is required. In a 100-bp run, Read 1 is 45 bp of barcode only, Index 1 is 8 bp and Read 2 contains microbial sequence. In a 300-bp run, Read 1 is 150 bp (first 45 bp barcode, last 75 bp microbial, adapter between).

Sequencing limitation. A custom Read-1 primer (IDT) is required, but its sequence is not printed in the preprint; the Read-1 landing site is therefore not computed.

Read content and handling

Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.

ReadCyclesContentInclude in sequence analysis?
Read 145custom Read-1 primer: bead barcode 1, linker, barcode 2 (100-bp run; 150 in a 300-bp run)No — extract identifiers only
Index 1 (i7)8Nextera i7 sample indexNo — use for sample demultiplexing
Read 2remainingmicrobial genomic sequenceYes — include in sequence analysis