Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. Considered in situ Hi-C, Hi-C (original), TCC. The inspected NG Capture-C clauses identify The complete and detailed protocol presented here, with new publicly available tools for library design and data analysis, will allow most laboratories to analyse chromatin conformation at levels of sensitivity and throughput that were previously impossible. / Importantly, multiple independent 3C libraries from different samples can now be processed in a single reaction greatly increasing throughput, minimising experimental va. These candidates do not isolate the same specific chemical strategy from generic capture/priming/amplification or assay-output overlap; no single defensible earlier analogue is assigned in this capped pass.
Davies et al., Nature Methods (2016); PMC4724891 accepted manuscript and Online Methods; published Supplementary Data probe workbook.
DpnII 3C contacts are sonicated and converted with NEBNext reagents and TruSeq indexed adapters, then selected by two rounds of biotin-probe hybridization, streptavidin capture and PCR from beads.
Native TruSeq adapter strands, index width/placement and PCR primer species remain unassigned. The expected sequencing library is distinct from the actual pre-index-PCR ligation product and denatured captured templates. The published Hba-1 probe is shown as an example; capture pools vary by viewpoint.
Reported double-capture enrichment.
Results paragraph on single versus double capture (PMC4724891 JATS): two sequential capture steps resulted in up to 1,000,000-fold enrichment
Figure 1a and Figure 2a legends (PMC4724891 JATS): double capture produced enrichments up to 3,000,000-fold
Modelled: The model encodes no fold-enrichment value; the two capture rounds are drawn without a yield claim. Evidence: Both values are printed in the open-access accepted manuscript; the paywalled publisher version of the main text was not inspected. Remaining uncertainty: Which maximum belongs to which experiment, and whether the published version harmonizes the numbers, is unresolved.
Key oligos
Published Hba-1 viewpoint probe example (Supplementary Data, oligo sheet row94): 5′-/5Biosg/- GATCCATGGTAGCACAGGGCAGCTAAGATGCAAGTCTGAAGGAGGAGTCTGGCGAGCTGCTCCTGCAGTTCCCTGGACCCAGAAGGATGAGCTAGCAGATTCACTTGAGCCAAAGGATTC -3'
Reaction workflow
NG Capture-C — next-generation Capture-C captured library
Digest fixed chromatin with DpnII. Inputs: DpnII (3 x 500 U, 37 °C, 16–24 h, after SDS/Triton X-100)
Heat-inactivate DpnII (65 °C) and proximity-ligate restriction fragments. Inputs: high-concentration T4 DNA ligase (Thermo Scientific), 16 °C overnight
Reverse cross-links and recover 3C DNA. Inputs: Proteinase K at 65 °C overnight, RNase, phenol-chloroform and ethanol precipitation
Sonicate recovered 3C DNA. Inputs: Covaris S220 sonication of 5 µg 3C DNA to about 200 bp
Add one 3-prime dA to each end. Inputs: NEBNext dA-tailing reagents
Present adapter and substrate ends. The Online Methods name Illumina TruSeq indexed adapters ligated with NEBnext reagents (E6000/E6040/E7335/E7500; E7370 for low cell numbers) but print no adapter strands or end geometry.
Index and amplify the 3C library. Inputs: library PCR primer 1 (sequence not printed); library PCR primer2; index incorporation stage unassigned; Herculase II PCR kit (Agilent), 6–8 cycles
Denature and hybridize 1.5–2 µg indexed library, or pooled indexed libraries to capture oligos at 47 °C for 64–72 h. Inputs: 5′-biotinylated 120-nt viewpoint capture oligo pool, round 1 (13 pmol); COT DNA, NimbleGen HE universal and index-specific blocking oligos, NimbleGen hybridization buffer
Round-1 streptavidin pull-down and SeqCap EZ washes. Inputs: M270 streptavidin beads with SeqCap EZ wash buffers (47 °C stringent washes). Other outputs: uncaptured round-1 library → discard
Amplify round-1 captured material from the beads (two reactions, AMPure XP cleanup). Inputs: SeqCap EZ Post LM-PCR oligo, first of pair (sequence not printed); SeqCap EZ Post LM-PCR oligo, second of pair (sequence not printed); SeqCap EZ Post-Capture LM-PCR master mix (18 cycles) or KAPA mix from SeqCap EZ accessory kit v2 (14 cycles). Other outputs: round-1 original bead/probe/template material after PCR; recovery unassigned → unresolved
Denature and hybridize 75% of round-1 amplified material, up to 2 µg to capture oligos at 47 °C for 24 h. Inputs: 5′-biotinylated 120-nt viewpoint capture oligo pool, round 2 (13 pmol); COT DNA, NimbleGen HE universal and index-specific blocking oligos, NimbleGen hybridization buffer
Round-2 streptavidin pull-down and SeqCap EZ washes. Inputs: M270 streptavidin beads with SeqCap EZ wash buffers (47 °C stringent washes). Other outputs: uncaptured round-2 library → discard
Amplify round-2 captured material from the beads (two reactions, AMPure XP cleanup). Inputs: SeqCap EZ Post LM-PCR oligo, first of pair (sequence not printed); SeqCap EZ Post LM-PCR oligo, second of pair (sequence not printed); SeqCap EZ Post-Capture LM-PCR master mix (18 cycles) or KAPA mix from SeqCap EZ accessory kit v2 (14 cycles). Other outputs: round-2 original bead/probe/template material after PCR; recovery unassigned → unresolved
Other material outcomes
uncaptured round-1 library — discard
not bound to a biotinylated probe; removed with the bead-binding and wash supernatants
Molecular structure is not represented in this graph.
round-1 original bead/probe/template material after PCR; recovery unassigned — unresolved
PCR copies captured templates without consuming their probe-bound original strands; their exact partition through AMPure recovery is unassigned.
round-1 original bead/probe/template material after PCR; recovery unassigned — unresolved
uncaptured round-2 library — discard
not bound to a biotinylated probe; removed with the bead-binding and wash supernatants
Molecular structure is not represented in this graph.
round-2 original bead/probe/template material after PCR; recovery unassigned — unresolved
PCR copies captured templates without consuming their probe-bound original strands; their exact partition through AMPure recovery is unassigned.
round-2 original bead/probe/template material after PCR; recovery unassigned — unresolved
Final sequencing library
Role-level native TruSeq ends around the DpnII contact fragment; no canonical single-index shell asserted.
Sequencing entry
Mostly MiSeq150nt paired-end, with one HiSeq100nt paired-end run. Index acquisition and cycles remain unassigned. DpnII digestion and identical-coordinate PCR-duplicate removal in analysis are computational, not physical molecular disposal.
Sequencing-primer binding on the final library
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
unassigned
150nt MiSeq or100nt HiSeq source alternatives; viewpoint/reporter fragment
Yes — include in sequence analysis
Read 2
unassigned
Opposite fragment end,150nt MiSeq or100nt HiSeq alternatives