Solid: source-documented · dashed: inferred · dotted gray: guessed earlier chemistry analogue. Guesses are not established ancestry; no link establishes identical chemistry.
No formal ancestor assigned in this review. Candidate-specific comparison: Restriction-ligation chromatin libraries and capture from selected viewpoints extended to recovering concurrent multi-junction molecules. Confidence is explicitly supported.
Oudelaar et al., Nature Genetics2018, doi:10.1038/s41588-018-0253-2; defining Methods and cited2018 detailed protocol.
Native NlaIII concatemers are gently sheared, adapted and indexed before two viewpoint-capture rounds. Captured DNA is amplified from streptavidin beads; capture probes remain separate molecules.
Published source boundaries: article Methods uses2.9nM total capture-probe pool; cited2018 ProtocolExchange v1 Capture enrichment p.7 says2.9nM per oligonucleotide. The2018 materials list p.2 names E6040, while its library-prep heading p.5 says E7370. The2019 v2 revision names E6040 and presents E7645 UltraII as a later low-input option; it does not identify the historical kit lot. Both detailed versions state10nmol in3.46µl gives2.9µM; arithmetic gives about2.9mM. The graph uses the source-listed end-repair/dA/ligation operations with actual kit identity and probe concentration unassigned. The article0.7:1 post-sonication cleanup differs from the2018 protocol1.8× instruction; the graph follows the article for that step. Superseded preprint values are not current authority. Native adapters, selected index members and PCR/USER end boundaries remain unassigned.
Post-sonication bead ratio.
Defining article Online Methods, Tri-C experimental procedure: Clean-up and size selection after sonication used AMPure XP at 0.7:1.
2018 Protocol Exchange method, Sonication step I.3 and note E (p. 5): 220 µl beads are added to the 120-µl sonicate (about 1.8x); all clean-ups use 1.8 volumes and size selection is called unnecessary.
Modelled: The graph uses the article's 0.7:1 size-selecting clean-up for the published experiment. Evidence: The defining article describes the libraries actually sequenced; the detailed method is a general protocol. Remaining uncertainty: Which ratio each sequenced library received is not stated beyond the article's sentence.
Digest fixed chromatin with NlaIII. Inputs: NlaIII, 3 x 600 U over 16-24 h at 37 °C
Heat-inactivate the digestion. Inputs: 65 °C for 20 min, then ice
Proximity-ligate NlaIII fragments in nuclei. Inputs: T4 DNA ligase, 720 U, overnight at 16 °C
Reverse cross-links and digest protein. Inputs: de-crosslinking with Proteinase K (3 U) overnight at 65 °C
RNase-treat and extract 3C DNA. Inputs: RNase (7.5 mU), phenol-chloroform, sodium acetate/ethanol precipitation at -80 °C, 70% ethanol wash
Sonicate gently to retain multiple junctions. Inputs: Covaris S220, one 55-s cycle, 10% duty, intensity 4, 200 cycles/burst, target ~450 bp
Clean up and size-select after sonication. Inputs: AMPure XP, 0.7:1 bead-to-sample. Other outputs: bead supernatant (fragments and solutes not bound at this ratio) → discard
End-repair sonicated 3C DNA. Inputs: NEBNext End Repair buffer and enzyme mix, 20 °C 30 min
Add one 3-prime dA to each end. Inputs: NEBNext dA-tailing buffer and Klenow, 37 °C 30 min
Present adapter and substrate ends. The article names Illumina TruSeq adaptors added with NEBNext reagents and the detailed method names the kit 'Adaptor'; neither prints the adaptor strands, their uracil position or the ligation-ready end.
Ligate Illumina adaptors. Inputs: Illumina TruSeq-compatible adaptor supplied with the NEBNext kit; Quick Ligation buffer and T4 DNA ligase, 20 °C 15 min
Treat the ligation with USER enzyme. Inputs: USER Enzyme Mix (3 µl), 37 °C 15 min. Other outputs: USER cleavage products; physical partition unassigned → unresolved
Bead clean-up after ligation and USER treatment. Inputs: AMPure XP, 1.8:1 bead-to-sample. Other outputs: bead supernatant after ligation/USER → discard
Seven-cycle indexing PCR. Inputs: NEB Universal primer; NEB Index primer (E7335/E7500 sets); Agilent Herculase II Fusion DNA polymerase
Pool libraries for one multiplexed capture. Additional template inputs: other differentially indexed Tri-C libraries
Denature at 95 °C and hybridize with probes at 47 °C for 64-72 h. Inputs: biotinylated 120-nt viewpoint capture oligos (Supplementary Table 5 coordinates); COT DNA plus NimbleGen TS-HE Universal and TS-HE Index blocking oligos
Round-1 streptavidin capture and stringent washes. Inputs: M-270 streptavidin beads and SeqCap washes. Other outputs: round-1 unbound/washed-off library → discard
Denature at 95 °C and hybridize with probes at 47 °C for 24 h. Inputs: biotinylated 120-nt viewpoint capture oligos (Supplementary Table 5 coordinates); COT DNA plus NimbleGen TS-HE Universal and TS-HE Index blocking oligos
Round-2 streptavidin capture and stringent washes. Inputs: M-270 streptavidin beads and SeqCap washes. Other outputs: round-2 unbound/washed-off library → discard
bead supernatant (fragments and solutes not bound at this ratio) — discard
supernatant removed from the magnetically held AMPure beads
Molecular structure is not represented in this graph.
USER cleavage products; physical partition unassigned — unresolved
Chemical USER cleavage does not determine physical recovery of its fragments.
Molecular structure is not represented in this graph.
bead supernatant after ligation/USER — discard
supernatant removed from the magnetically held AMPure beads
Molecular structure is not represented in this graph.
round-1 unbound/washed-off library — discard
removed in bead supernatants and 47 °C stringent washes
Molecular structure is not represented in this graph.
round-2 unbound/washed-off library — discard
removed in bead supernatants and 47 °C stringent washes
Molecular structure is not represented in this graph.
Final sequencing library
Illustrative multiway endpoint, with physical shearing-coordinate identity and native adapter/index roles. It is not an assumed canonical TruSeq library.
Sequencing entry
First erythroid experiment MiSeq v2 PE250; second multiplexed erythroid/ES experiment NextSeq v2 PE150. Index acquisition remains unassigned.
Sequencing limitation. MiSeq PE250 first experiment or NextSeq PE150 second experiment; native primer/index acquisition unassigned.
Read content and handling
Read roles and contents are source-declared because exact sequencing-primer geometry is unavailable.
Read
Cycles
Content
Include in sequence analysis?
Read 1
250 first experiment;150 second
viewpoint/reporter contacts; computational duplicate filtering by physical coordinates