Olink Explore — proximity extension assay with NGS readout

Protocol relationships

Some predecessor or candidate links are withheld until the corresponding protocol pages are available.

No formal ancestor assigned in this review. Plausible earlier chemistry analogue; descent or inspiration cannot be substantiated. Proximity-dependent antibody-DNA signal conversion followed by NGS readout; OlinkExplore uses PEA extension instead of the earlier PLA joining reaction.

Explore relationships and sequence similarity

Research notes

Wik et al., Molecular & Cellular Proteomics (2021).

Matched antibody–oligo pairs co-bind a protein, hybridize in proximity and template polymerase extension. Two PCR stages retain the paired assay barcodes and add an inline sample index for counting.

Olink publishes the 148-bp element order and run layout. Complete probe, assay-barcode, hybridization-arm, sample-index and PCR-primer sequences remain unverified in the source audit. Only the Illumina end is rendered base by base: the 20-nt P5 and 24-nt P7 portions are printed in Olink's patent, while the linker and Rd1SP bases following P5 are INFERRED as the standard Illumina TruSeq P5 end (consistent with the published 148-bp length and 66-cycle read, but not printed by Olink). The other regions remain structured roles.
Wording of the common forward-primer identity differs.
  • Wik et al. 2021, Experimental Procedures, PCR Amplification (PMC8633680 JATS line 168): forward PCR1 primer "complementary to Illumina's P5 adapter sequence"
  • Olink patent WO2021191442A1, worked PCR1/PCR2 example (Google Patents text lines 4135–4171): forward common primer "comprises the Illumina P5 sequencing adapter sequence (SEQ ID NO: 1)"

Modelled: The model gives the forward primer the P5 sense sequence, as the patent states and as the article's probe design requires (the forward probe itself carries P5 and Rd1SP). Evidence: Both statements come from Olink originals; the article also calls the reverse primer "complementary" to a common probe sequence, suggesting loose wording. Remaining uncertainty: Neither source prints the complete forward-primer bases, so its full sequence and any 5' extension beyond the 20-nt P5 portion remain unverified.

Reaction workflow

bead-purified 148-bp Olink Explore library

plasma sample, undiluted or diluted 1:10, 1:100 or 1:1000 sample 5'- target proteins[target proteins] -3' target proteins Bind matched oligo-antibody probes to the same protein antigen-bound PEA probe pair 5'- forward antibody + oligo[forward antibody + oligo]target protein[target protein]reverse antibody + oligo[reverse antibody + oligo]paired hybridization arms[paired hybridization arms] -3' forward antibody + oligo target protein reverse antibody + oligo paired hybridization arms Extend across the hybridized probe arms proximity-extension reporter 5'- P5 and Read 1 precursor[P5 and Read 1 precursor]forward assay barcode[forward assay barcode]copied hybridization junction[copied hybridization junction]reverse assay barcode[reverse assay barcode]common reverse-PCR handle[common reverse-PCR handle] -3' P5 and Read 1 precursor forward assay barcode copied hybridization junction reverse assay barcode common reverse-PCR handle Preamplify every extended reporter with universal primers proximity-extension reporter 5'- P5 and Read 1 precursor[P5 and Read 1 precursor]forward assay barcode[forward assay barcode]copied hybridization junction[copied hybridization junction]reverse assay barcode[reverse assay barcode]common reverse-PCR handle[common reverse-PCR handle] -3' P5 and Read 1 precursor forward assay barcode copied hybridization junction reverse assay barcode common reverse-PCR handle Pool PCR1 products from abundance blocks A–D proximity-extension reporter 5'- P5 and Read 1 precursor[P5 and Read 1 precursor]forward assay barcode[forward assay barcode]copied hybridization junction[copied hybridization junction]reverse assay barcode[reverse assay barcode]common reverse-PCR handle[common reverse-PCR handle] -3' P5 and Read 1 precursor forward assay barcode copied hybridization junction reverse assay barcode common reverse-PCR handle Add the inline sample index and P7 end in ten PCR cycles 148-bp PCR2 amplicons of one sample 5'- P5 adapter (patent SEQ ID 1) · 20 bp · Tm 59.0 °CAATGATACGGCGACCACCGAcanonical Illumina sequence between P5 and Rd1SP · 5 bpGATCTRead 1 sequencing-primer site · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTforward assay barcode[forward assay barcode]probe-arm hybridization junction[probe-arm hybridization junction]reverse assay barcode[reverse assay barcode]inline sample index[inline sample index]P7 reverse complement (patent SEQ ID 2) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' 148-bp PCR2 amplicons of one sample 3'- P5 adapter (patent SEQ ID 1)' · 20 bp · Tm 58.9 °CTTACTATGCCGCTGGTGGCTcanonical Illumina sequence between P5 and Rd1SP' · 5 bpCTAGARead 1 sequencing-primer site' · 33 bp · Tm 67.3 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAforward assay barcode'[forward assay barcode]probe-arm hybridization junction'[probe-arm hybridization junction]reverse assay barcode'[reverse assay barcode]inline sample index'[inline sample index]P7 reverse complement (patent SEQ ID 2)' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5' Pool every PCR2 sample of a panel into one of four libraries unpurified panel library pool 5'- P5 adapter (patent SEQ ID 1) · 20 bp · Tm 59.0 °CAATGATACGGCGACCACCGAcanonical Illumina sequence between P5 and Rd1SP · 5 bpGATCTRead 1 sequencing-primer site · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTforward assay barcode[forward assay barcode]probe-arm hybridization junction[probe-arm hybridization junction]reverse assay barcode[reverse assay barcode]inline sample index[inline sample index]P7 reverse complement (patent SEQ ID 2) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' unpurified panel library pool 3'- P5 adapter (patent SEQ ID 1)' · 20 bp · Tm 58.9 °CTTACTATGCCGCTGGTGGCTcanonical Illumina sequence between P5 and Rd1SP' · 5 bpCTAGARead 1 sequencing-primer site' · 33 bp · Tm 67.3 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAforward assay barcode'[forward assay barcode]probe-arm hybridization junction'[probe-arm hybridization junction]reverse assay barcode'[reverse assay barcode]inline sample index'[inline sample index]P7 reverse complement (patent SEQ ID 2)' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5' Purify each panel library with AMPure XP beads bead-purified 148-bp Olink Explore library 5'- P5 adapter (patent SEQ ID 1) · 20 bp · Tm 59.0 °CAATGATACGGCGACCACCGAcanonical Illumina sequence between P5 and Rd1SP · 5 bpGATCTRead 1 sequencing-primer site · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTforward assay barcode[forward assay barcode]probe-arm hybridization junction[probe-arm hybridization junction]reverse assay barcode[reverse assay barcode]inline sample index[inline sample index]P7 reverse complement (patent SEQ ID 2) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' bead-purified 148-bp Olink Explore library 3'- P5 adapter (patent SEQ ID 1)' · 20 bp · Tm 58.9 °CTTACTATGCCGCTGGTGGCTcanonical Illumina sequence between P5 and Rd1SP' · 5 bpCTAGARead 1 sequencing-primer site' · 33 bp · Tm 67.3 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAforward assay barcode'[forward assay barcode]probe-arm hybridization junction'[probe-arm hybridization junction]reverse assay barcode'[reverse assay barcode]inline sample index'[inline sample index]P7 reverse complement (patent SEQ ID 2)' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5'
  1. Bind matched oligo-antibody probes to the same protein. Inputs: matched antibody probe pair; conjugated forward and reverse PEA oligos; 0.6 µl block incubation mix + 0.2 µl sample, 4 °C for 16–24 h. Other outputs: free or non-proximal probes left in the well (no wash described) → unresolved
  2. Extend across the hybridized probe arms. Inputs: polymerase in the Olink PCR1 mix (initial extension 50 °C, 20 min)
  3. Preamplify every extended reporter with universal primers. Inputs: universal PCR1 forward primer; universal PCR1 reverse primer; Olink PCR1 enzyme
  4. Pool PCR1 products from abundance blocks A–D. Inputs: equal-volume abundance-block pooling rule
  5. Add the inline sample index and P7 end in ten PCR cycles. Inputs: PCR2 forward primer (same species as PCR1); sample-indexed P7 reverse primer; Olink PCR2 enzyme
  6. Pool every PCR2 sample of a panel into one of four libraries. Inputs: pool all PCR2 samples of one panel (epMotion)
  7. Purify each panel library with AMPure XP beads. Inputs: AMPure XP beads, 80 µl per 50 µl library. Other outputs: primers, primer dimers, dNTPs and other unbound contaminants → discard

Other material outcomes

free or non-proximal probes left in the well (no wash described) — unresolved

No removal is described: the PCR1/extension mix is added to each incubation reaction with no intervening wash, so these probes are inferred to be carried into the extension/PCR1 reaction. Wik et al. state only that proximal matched pairs generate detectable amplicons; the model does not follow these oligos further or assign their removal to the later AMPure XP cleanup.

Molecular structure is not represented in this graph.

primers, primer dimers, dNTPs and other unbound contaminants — discard

Removed in the bead supernatant before sequencing.

Molecular structure is not represented in this graph.

Proximity-extension topology

Two antibody–oligo conjugates must bind the same analyte closely enough for their terminal arms to pair. Polymerase then copies across the paired arms, joining the two assay identities in one reporter. Probe bases are proprietary and are therefore shown by role only.
Matched antibody oligos co-bind one analyte, hybridize and template extension1. Matched probes co-bind one analyte2. Proximal arms hybridize and extendtarget proteintarget proteinforward antibody–oligo with covalently attached DNA probeforward antibody–oligoreverse antibody–oligo with covalently attached DNA probereverse antibody–oligoforward barcodereverse barcodeunbound or mismatched probes do not form the paired templatetarget proteintarget proteinforward antibody–oligo with covalently attached DNA probeforward antibody–oligoreverse antibody–oligo with covalently attached DNA probereverse antibody–oligoforward barcodereverse barcodepolymerase extensionpaired assay barcodes become one amplifiable reporter

Final sequencing library

INFERRED — linker and Rd1SP bases taken from Illumina's standard P5 end, not printed by Olink; the 66-nt inline length follows from that inferred 58-nt end. Published 148-bp element order: P5, the Read 1 site, a proprietary inline region containing both assay barcodes, the copied probe junction and sample index, then P7.
library 5'- P5 adapter (patent SEQ ID 1) · 20 bp · Tm 59.0 °CAATGATACGGCGACCACCGAcanonical Illumina sequence between P5 and Rd1SP · 5 bpGATCTRead 1 sequencing-primer site · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTforward assay barcode[forward assay barcode]probe-arm hybridization junction[probe-arm hybridization junction]reverse assay barcode[reverse assay barcode]inline sample index[inline sample index]P7 reverse complement (patent SEQ ID 2) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' library 3'- P5 adapter (patent SEQ ID 1)' · 20 bp · Tm 58.9 °CTTACTATGCCGCTGGTGGCTcanonical Illumina sequence between P5 and Rd1SP' · 5 bpCTAGARead 1 sequencing-primer site' · 33 bp · Tm 67.3 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAforward assay barcode'[forward assay barcode]probe-arm hybridization junction'[probe-arm hybridization junction]reverse assay barcode'[reverse assay barcode]inline sample index'[inline sample index]P7 reverse complement (patent SEQ ID 2)' · 24 bp · Tm 59.3 °CTAGAGCATACGGCAGAAGACGAAC -5' P5 adapter (patent SEQ ID 1) forward assay barcode probe-arm hybridization junction reverse assay barcode inline sample index P7 reverse complement (patent SEQ ID 2) canonical Illumina sequence between P5 and Rd1SP Read 1 sequencing-primer site ^ feature barcode · forward ^ feature barcode · reverse ^ sample index

Sequencing primers

A Read 1 primer binds the published Rd1SP site (bases inferred as Illumina's standard Read 1 site). The NovaSeq run acquires one 66-cycle read and no separate index read; assay and sample identities are inline.

Sequences come from lib/; the landing site and the first bases of each read are computed from this page's final library, so they cannot drift from it.

Sequencing primers on the final library
Read 1 / TruSeq Read 1 5'- TruSeq Read 1 · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCT -3' final library 5'- P5 adapter (patent SEQ ID 1) · 20 bp · Tm 59.0 °CAATGATACGGCGACCACCGAcanonical Illumina sequence between P5 and Rd1SP · 5 bpGATCTRead 1 sequencing-primer site · 33 bp · Tm 66.9 °CACACTCTTTCCCTACACGACGCTCTTCCGATCTforward assay barcode[forward assay barcode]probe-arm hybridization junction[probe-arm hybridization junction]reverse assay barcode[reverse assay barcode]inline sample index[inline sample index]P7 reverse complement (patent SEQ ID 2) · 24 bp · Tm 59.8 °CATCTCGTATGCCGTCTTCTGCTTG -3' 3'- P5 adapter (patent SEQ ID 1) · 20 bp · Tm 59.0 °CTTACTATGCCGCTGGTGGCTcanonical Illumina sequence between P5 and Rd1SP · 5 bpCTAGARead 1 sequencing-primer site · 33 bp · Tm 66.9 °CTGTGAGAAAGGGATGTGCTGCGAGAAGGCTAGAforward assay barcode[forward assay barcode]probe-arm hybridization junction[probe-arm hybridization junction]reverse assay barcode[reverse assay barcode]inline sample index[inline sample index]P7 reverse complement (patent SEQ ID 2) · 24 bp · Tm 59.8 °CTAGAGCATACGGCAGAAGACGAAC -5' ^ feature barcode · forward ^ feature barcode · reverse ^ sample index
ReadPrimerSequenceLands onFirst bases read
Read 1TruSeq Read 1
Illumina "Illumina Adapter Sequences" #1000000002694
5'-ACACTCTTTCCCTACACGACGCTCTTCCGATCT-3'anneals to the bottom strand over Read 1 sequencing-primer site… (from forward assay barcode)

Read content and handling

Read roles and contents are source-declared; computed primer landing is shown above only for the primer sites this model represents.

ReadCyclesContentInclude in sequence analysis?
Read 166forward assay barcode + reverse assay barcode + inline sample indexNo — extract identifiers and demultiplex