PrimeFlow RNA Assay

Protocol relationships

No curated ancestry links yet. This does not establish independent origins.

No formal ancestor assigned in this review. Named earlier candidates considered: RNAscope (2012; discovery overlap amplification:branched-DNA signal amplification, topology:branched hybridization tree, strand_handling:RNA hybridization); RASL-seq (2012; discovery overlap starting_material:total RNA, fragmentation:no fragmentation). These are not promoted to guessed ancestry from metadata alone: the inspected child source and the bounded comparison sources recorded above do not establish a specific sufficiently matching chemical operation for these candidates. Original-source comparison of these actual targets is deferred; this is an unresolved scoped assessment, not evidence of independent invention.

Explore relationships and sequence similarity

Research notes

Commercial protocol: Thermo Fisher MAN0019788 Rev B.0; defining flow-RNA application: Porichis et al. (2014).

Adjacent target-probe pairs detect RNA inside fixed, permeabilized suspension cells; a branched-DNA tree amplifies fluorescence for single-cell flow cytometry, optionally alongside antibody staining.

Sequence boundary. Porichis et al. Supplementary Table 1 publishes the target-RNA intervals and sequences used to design its IL-2, IL-21, IFN-γ, IDO, HMBS and miRNA probe sets. The article's Methods says probe sequences are detailed there, but the table columns contain target regions and coordinates, not complete manufactured probes. These determine the complementary target-binding arms. The manufactured probes' universal tails, including their lengths and docking bases, and the preamplifier, amplifier and label-probe sequences are not given in the reviewed table or 2022 vendor guide. Linked ViewRNA sources remain under review. Porichis et al. (2014, Methods and Results) report three available fluorochrome probe sets (Alexa 488, 647 and 750); the model follows the later PrimeFlow user guide (2022, probe-type table), which lists four types (1, 4, 6 and 10). This is a product-version difference, not evidence that the 2014 experiment used Type 10. The same 2022 guide is internally inconsistent about structures: its product description (p.5) says “three different amplification structures” allow up to four RNA targets, whereas its assay guidelines (p.9) and workflow figure list four probe types (1, 4, 6 and 10), each with its own dye. The model shows four types and does not claim how many distinct amplification structures underlie them. The guide states 400 label-probe sites per complete tree but not how they divide between amplifiers and label probes; step 3 therefore models only the total and draws representative arms without per-level counts.

(1) Prepare the specimen

The 2022 guide (Day 1 steps 4–19) fixes surface-stained cells in Fixation Buffer 1 (30 min, 2–8 °C), permeabilizes them with RNase inhibitors, allows intracellular antibody staining, then fixes again in Fixation Buffer 2 (60 min, room temperature) before washes. Porichis et al. (2014, Methods) likewise fixed, permeabilized with cold methanol and fixed a second time, so RNA fluorescence can be combined with immunophenotyping.
suspension cells ± surface antibodies → Fixation Buffer 1 → permeabilize → intracellular antibodies (optional) → Fixation Buffer 2

(2) Hybridize adjacent target-probe pairs

A gene-specific set contains 20–40 adjacent probe pairs (2022 guide). Preamplifier molecules hybridize only when both halves of a pair have bound. Target probes are diluted 1:20 and hybridized for 2 h at 40 °C, then washed (guide and Porichis et al. Methods). Porichis et al. disclose the target regions used in their sets, but not the universal tails or amplification-tree oligos.
left target probe 3'- left probeXXXXXXXXXXXXleft Z tailXXXXXX -5' half of preamplifier landing site right target probe 3'- right Z tailXXXXXXright probeXXXXXXXXXXXX -5' half of preamplifier landing site target RNA 5'- left target siteXXXXXXXXXXXXright target siteXXXXXXXXXXXX -3' schematic widths; X = undisclosed base

Paper-disclosed adjacent target regions

The first adjacent IL-2 pair is shown as a concrete example. The two target sequences are transcribed from Supplementary Table 1; the paired probe arms are their computed reverse complements. They are not complete orderable PrimeFlow probes because neither the bases nor lengths of the universal tails were published.

IL-2 target region, NM_021803 bases 2–24: 5'- CCTTGGTCTCGTTTTCACTTCAG -3'

IL-2 target region, NM_021803 bases 25–52: 5'- TCTCATAAGTACCAACAGTAGAGCTAGA -3'

The target regions are contiguous. Complementarity and probe orientation are derived by the shared model; the non-nucleotide tail placeholders mark the unpublished commercial part without inventing a length. The downstream tree is therefore a topological view, not a claimed oligo sequence.
implied left probe arm 3'- left target-binding arm · 23 bp · Tm 56.9 °CGGAACCAGAGCAAAAGTGAAGTCleft universal tail[undisclosed tail] -5' implied right probe arm 3'- right universal tail[undisclosed tail]right target-binding arm · 28 bp · Tm 58.0 °CAGAGTATTCATGGTTGTCATCTCGATCT -5' published target-RNA regions 5'- left disclosed target region · 23 bp · Tm 56.7 °CCCTTGGTCTCGTTTTCACTTCAGright disclosed target region · 28 bp · Tm 56.8 °CTCTCATAAGTACCAACAGTAGAGCTAGA -3' binding arms are derived complements; universal tails were not disclosed

(3) Assemble the branched-DNA signal tree

Five representative amplifier arms are drawn without crossings; only the total per tree is modelled, so the arm and label counts drawn are representative, not per-level multiplicities. The 2022 user guide (p.5) states only that a complete tree has 400 label-probe binding sites; it gives no amplifier-per-preamplifier or label-per-amplifier split, so none is modelled. The modelled tree carries 400 label-probe sites, and the documented target-probe range gives 8,000–16,000 theoretical label sites per target RNA.
5′3′ target RNAone adjacent target-probe pairpreamplifier trunkamplifier branches (per-level count not modelled)label probes (per-amplifier count not modelled)400 potential labels per signal tree

(4) Detect the signal

PreAmp Mix and Amp Mix are each hybridized for 1.5 h at 40 °C with washes between, then label probes (1:100) for 1 h at 40 °C (guide Day 2; Porichis et al. Methods). Type 1 (Alexa Fluor 647), Type 4 (488), Type 6 (750) and Type 10 (568) label probes allow up to four RNA targets before standard flow-cytometric compensation and analysis.
fluorophore-conjugated label probes → fluorescence intensity per intact cell

Measurement, not sequencing

PrimeFlow produces per-cell fluorescence measured by a flow cytometer, not a sequencing library. There are therefore no sequencing adapters, indices, sequencing-primer sites or base-call reads.

Read content and handling

This is a branched-DNA imaging/flow-cytometry assay, not an NGS library.

ReadCyclesContentInclude in sequence analysis?
Sequencing outputnot fixedNo sequencing library or sequencing readsNo — assay readout is not sequencing