Week 5 demo: the connected catchment budget

How do atmospheric acid input, accessible neutralisation, reference alkalinity, and water export combine in an annual budget?

Use with the integrated case and its exercises.

Predict first

Predict how halving the water-equivalent alkalinity concentration differs from halving the annual alkalinity export. Which input changes can cause each?

Explore the model

Use the sliders or keyboard arrow keys while a slider is focused. Reset restores the starting values; reference-case buttons set all inputs for that case.

The reference calculation below can be used while the controls load or when JavaScript is unavailable.

Questions to try

  1. Choose Worked catchment. Close the acid budget in annual equivalents before looking at concentrations.
  2. Choose Less neutralisation. Trace the effect on residual acidity and reference-adjusted alkalinity.
  3. Choose Double water export. Verify that annual acid and alkalinity amounts stay fixed while their flow-weighted concentrations halve.
  4. Choose Capacity exceeds input. Why is unused capacity not counted as newly generated alkalinity in this comparison?
  5. Choose Exceed reference alkalinity. Explain the signed negative alkalinity result without calling it a negative concentration or inferring a pH.

Hand check and static reference

Quantity Worked catchment Less neutralisation
Acid input 40000 eq/year 40000 eq/year
Acid actually neutralised 30000 eq/year 20000 eq/year
Residual acid 10000 eq/year 20000 eq/year
Reference alkalinity export 50000 eq/year 50000 eq/year
Adjusted alkalinity export 40000 eq/year 30000 eq/year
Adjusted alkalinity, at 500 million L/year 0.0800 meq/L 0.0600 meq/L

The base residual acidity is 0.0200 meq/L. It differs from the week 1 before-neutralisation value because this budget includes acid consumed in the catchment.

Model conditions

This is a constructed annual equivalent budget, not a dynamic lake model. Accessible capacity caps how much of the added acid can react; unused capacity is not credited as extra alkalinity. Residual acidity is subtracted from an explicitly supplied reference annual alkalinity export. The other terms stay fixed when one slider changes. A real change in water flow could also alter weathering, transport, and retention. A pH prediction requires inorganic carbon, gas exchange, and appropriate acid–base constraints. Use the closed-water demo for the separate pulse problem.

Explain the result

What additional measurements would you need to connect this annual budget to a lake’s pH response and test whether neutralisation really changed?